Volumn 2, Issue 1, 2010, Pages 28-32

Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources

Author keywords

2D anisotropy function; Brachytherapy; Dosimetry; Interpolation; Radial dose function; TG 43

Indexed keywords

CESIUM 137; COBALT 60; IRIDIUM 192; YTTERBIUM;

EID: 77953427139     PISSN: 1689832X     EISSN: None     Source Type: Journal    
DOI: 10.5114/jcb.2010.13715     Document Type: Article
Times cited : (9)

References (24)
  • 1
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group No. 43
    • Nath R, Anderson LL, Luxton G et al. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys 1995; 22: 209-234.
    • (1995) Med Phys , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3
  • 2
    • 1142304255 scopus 로고    scopus 로고
    • Update of AAPM task group No. 43 report: A revised AAPM protocol for brachytherapy dose calculation
    • Rivard MJ, Coursey BM, DeWerd LA et al. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculation. Med Phys 2004; 31: 633-674.
    • (2004) Med Phys , vol.31 , pp. 633-674
    • Rivard, M.J.1    Coursey, B.M.2    DeWerd, L.A.3
  • 3
    • 34447302063 scopus 로고    scopus 로고
    • Supplement to the 2004 update of the AAPM task group no. 43 report
    • Rivard MJ, Butler WM, DeWerd LA et al. Supplement to the 2004 update of the AAPM Task Group No. 43 Report. Med Phys 2007; 34: 2187-2205.
    • (2007) Med Phys , vol.34 , pp. 2187-2205
    • Rivard, M.J.1    Butler, W.M.2    DeWerd, L.A.3
  • 4
    • 70349419991 scopus 로고    scopus 로고
    • Bi- and tri-exponential fitting to TG-43 radial dose functions of brachytherapy sources based on a genetic algorithm
    • Wu X, Brezovich IA, Fiveash JB. Bi- and tri-exponential fitting to TG-43 radial dose functions of brachytherapy sources based on a genetic algorithm. Brachytherapy 2009; 8: 361-366.
    • (2009) Brachytherapy , vol.8 , pp. 361-366
    • Wu, X.1    Brezovich, I.A.2    Fiveash, J.B.3
  • 6
    • 0033733769 scopus 로고    scopus 로고
    • Fitting and benchmarking of dosimetry data for new brachytherapy sources
    • Furhang EE and Wallace RE. Fitting and benchmarking of dosimetry data for new brachytherapy sources. Med Phys 2000; 27: 2302-2306.
    • (2000) Med Phys , vol.27 , pp. 2302-2306
    • Furhang, E.E.1    Wallace, R.E.2
  • 7
    • 85027217411 scopus 로고    scopus 로고
    • Comment on "functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM radiation therapy committee task group 43"
    • [Med Phys 1999; 26: 153-160] and "Fitting and benchmarking of dosimetry data for new brachytherapy sources"[Med Phys 2000; 27: 2302-2306]
    • Fung AY. Comment on "Functional fitting of interstitial brachytherapy dosimetry data recommended by the AAPM Radiation Therapy Committee Task Group 43"[Med Phys 1999; 26: 153-160] and "Fitting and benchmarking of dosimetry data for new brachytherapy sources"[Med Phys 2000; 27: 2302-2306]. Med Phys 2007; 28: 400.
    • (2007) Med Phys , vol.28 , pp. 400
    • Fung, A.Y.1
  • 9
    • 0345381862 scopus 로고    scopus 로고
    • Technical note: Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism
    • Lliso F, Perez-Calatayud J, Carmona V et al. Technical note: Fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism. Med Phys 2003; 30: 651-654.
    • (2003) Med Phys , vol.30 , pp. 651-654
    • Lliso, F.1    Perez-Calatayud, J.2    Carmona, V.3
  • 10
    • 33845939280 scopus 로고    scopus 로고
    • Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 keV
    • Li Z, Das R K, DeWerd L A et al. Dosimetric prerequisites for routine clinical use of photon emitting brachytherapy sources with average energy higher than 50 keV. Med Phys 2007; 34: 37-40.
    • (2007) Med Phys , vol.34 , pp. 37-40
    • Li, Z.1    Das, R.K.2    DeWerd, L.A.3
  • 12
    • 0034068736 scopus 로고    scopus 로고
    • 169Yb brachytherapy sources: An EGS4 Monte Carlo study
    • 169Yb brachytherapy sources: an EGS4 Monte Carlo study. Phys Med Biol 2000; 45: 703-717.
    • (2000) Phys Med Biol , vol.45 , pp. 703-717
    • Mainegra, E.1    Capote, R.2    López, E.3
  • 13
    • 34548349000 scopus 로고    scopus 로고
    • Technical note: Dosimetric study of a new Co-60 source used in brachytherapy
    • Granero D, Perez-Calatayud J, Ballester F. Technical note: Dosimetric study of a new Co-60 source used in brachytherapy. Med Phys 2007; 34: 3485-3488.
    • (2007) Med Phys , vol.34 , pp. 3485-3488
    • Granero, D.1    Perez-Calatayud, J.2    Ballester, F.3
  • 14
    • 12844257368 scopus 로고    scopus 로고
    • Monte Carlo and experimental derivation of TG-43 dosimetric parameters for CSM-type Cs-137 sources
    • Perez-Calatayud J, Granero D, Casal E et al. Monte Carlo and experimental derivation of TG-43 dosimetric parameters for CSM-type Cs-137 sources. Med Phys 2005: 28-36.
    • (2005) Med Phys , pp. 28-36
    • Perez-Calatayud, J.1    Granero, D.2    Casal, E.3
  • 15
    • 41449084989 scopus 로고    scopus 로고
    • Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources
    • Granero D, Perez-Calatayud J, Ballester F. Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources. Med Phys 2008; 35: 1280-1287.
    • (2008) Med Phys , vol.35 , pp. 1280-1287
    • Granero, D.1    Perez-Calatayud, J.2    Ballester, F.3
  • 16
    • 33845287284 scopus 로고    scopus 로고
    • A dosimetric study on the Ir-192 HDR Flexisource
    • Granero D, Perez-Calatayud J, Casal E et al. A dosimetric study on the Ir-192 HDR Flexisource. Med Phys 2006; 33: 4578-4582.
    • (2006) Med Phys , vol.33 , pp. 4578-4582
    • Granero, D.1    Perez-Calatayud, J.2    Casal, E.3
  • 18
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4 - A simulation toolkit
    • See also, last accessed 14 February 2010
    • Agostinelli S, Allison J, Amako K et al. GEANT4 - a Simulation Toolkit. Nuc Ins Meth 2003; A506: 250-303. See also http://geant4.web.cern.ch/geant4 last accessed 14 February 2010.
    • (2003) Nuc Ins Meth , vol.A506 , pp. 250-303
    • Agostinelli, S.1    Allison, J.2    Amako, K.3
  • 20
    • 77953367464 scopus 로고    scopus 로고
    • NUDAT 2.5, National Nuclear Data Center, Brookhaven National Laboratory, last accessed 14 February 2010
    • NUDAT 2.5, National Nuclear Data Center, Brookhaven National Laboratory, http://www.nndc.bnl.gov/nudat2/ last accessed 14 February 2010.
  • 21
    • 34447341743 scopus 로고    scopus 로고
    • Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source
    • Medich DC, Munro JJ. Monte Carlo characterization of the M-19 high dose rate Iridium-192 brachytherapy source. Med Phys 2007; 34: 1999-2006.
    • (2007) Med Phys , vol.34 , pp. 1999-2006
    • Medich, D.C.1    Munro, J.J.2
  • 22
    • 31044436651 scopus 로고    scopus 로고
    • Monte Carlo characterization of an Ytterbium-169 high dose rate brachytherapy source with analysis of statical uncertainty
    • Medich DC, Tries MA, Munro JJ. Monte Carlo characterization of an Ytterbium-169 high dose rate brachytherapy source with analysis of statical uncertainty. Med Phys 2006; 33: 163-172.
    • (2006) Med Phys , vol.33 , pp. 163-172
    • Medich, D.C.1    Tries, M.A.2    Munro, J.J.3
  • 23
    • 66449131989 scopus 로고    scopus 로고
    • The evolution of brachytherapy treatment planning systems
    • Rivard MJ, Venselaar JLM, Beaulieu L. The evolution of brachytherapy treatment planning systems. Med Phys 2009; 36: 2136-2153.
    • (2009) Med Phys , vol.36 , pp. 2136-2153
    • Rivard, M.J.1    Venselaar, J.L.M.2    Beaulieu, L.3
  • 24
    • 69549114520 scopus 로고    scopus 로고
    • Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons
    • Ballester F, Granero D, Perez-Calatayud J et al. Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons. Med Phys 2009; 36: 4250-4256
    • (2009) Med Phys , vol.36 , pp. 4250-4256
    • Ballester, F.1    Granero, D.2    Perez-Calatayud, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.