Volumn 33, Issue 12, 2006, Pages 4578-4582

A dosimetric study on the Ir-192 high dose rate Flexisource

Author keywords

Brachytherapy; Dosimetry; HDR; Ir 192; Monte Carlo

Indexed keywords

DOSIMETRY; TABLE LOOKUP;

EID: 33845287284     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2388154     Document Type: Article
Times cited : (57)

References (22)
  • 2
    • 0028919251 scopus 로고
    • Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM RadiationTherapy Committee Task Group No. 43
    • R. Nath, L. L. Anderson, G. Luxton, K. A. Weaver, J. F. Williamson, and A. S. Meigooni, " Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM RadiationTherapy Committee Task Group No. 43., " Med. Phys. 22, 209-234 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 209-234
    • Nath, R.1    Anderson, L.L.2    Luxton, G.3    Weaver, K.A.4    Williamson, J.F.5    Meigooni, A.S.6
  • 3
    • 0032427802 scopus 로고    scopus 로고
    • Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources
    • J. F. Williamson, B. M. Coursey, L. A. DeWerd, W. F. Hanson, and R. Nath, " Dosimetric prerequisites for routine clinical use of new low energy photon interstitial brachytherapy sources., " Med. Phys. 25, 2269-2270 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2269-2270
    • Williamson, J.F.1    Coursey, B.M.2    Dewerd, L.A.3    Hanson, W.F.4    Nath, R.5
  • 4
    • 0038377458 scopus 로고    scopus 로고
    • GEANT4-A simulation toolkit
    • S. Agostinelli, " GEANT4-A simulation toolkit., " Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003). (See also http://geant4.web.cern.ch/geant4.)
    • (2003) Nucl. Instrum. Methods Phys. Res. a , vol.506 , pp. 250-303
    • Agostinelli, S.1
  • 5
    • 85140805320 scopus 로고    scopus 로고
    • S. Agostinelli, " GEANT4-A simulation toolkit., " Nucl. Instrum. Methods Phys. Res. A 506, 250-303 (2003). (See also http://geant4.web.cern.ch/geant4.)
    • Agostinelli, S.1
  • 6
    • 11244309250 scopus 로고    scopus 로고
    • Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds
    • F. Ballester, D. Granero, J. Ṕrez-Calatayud, E. Casal, and V. Puchades, " Monte Carlo dosimetric study of Best Industries and Alpha Omega Ir-192 brachytherapy seeds., " Med. Phys. 31, 3298-3305 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 3298-3305
    • Ballester, F.1    Granero, D.2    Ṕrez-Calatayud, J.3    Casal, E.4    Puchades, V.5
  • 7
    • 12144291169 scopus 로고    scopus 로고
    • Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects
    • J. Ṕrez-Calatayud, D. Granero, F. Ballester, V. Puchades, and E. Casal, " Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: Evaluation of applicator attenuation and superposition approximation effects., " Med. Phys. 31, 493-499 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 493-499
    • Ṕrez-Calatayud, J.1    Granero, D.2    Ballester, F.3    Puchades, V.4    Casal, E.5
  • 8
    • 23244458150 scopus 로고    scopus 로고
    • Monte Carlo calculation of TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source
    • D. Granero, J. Ṕrez-Calatayud, and F. Ballester, " Monte Carlo calculation of TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source., " Radiother. Oncol. 76, 79-85 (2005).
    • (2005) Radiother. Oncol. , vol.76 , pp. 79-85
    • Granero, D.1    Ṕrez-Calatayud, J.2    Ballester, F.3
  • 10
    • 0031739032 scopus 로고    scopus 로고
    • Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    • G. M. Daskalov, E. Löffler, and J. F. Williamson, " Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source., " Med. Phys. 25, 2200-2208 (1998).
    • (1998) Med. Phys. , vol.25 , pp. 2200-2208
    • Daskalov, G.M.1    Löffler, E.2    Williamson, J.F.3
  • 11
    • 84864166247 scopus 로고    scopus 로고
    • a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY;
    • National Nuclear Data Center. Nuclear data from NuDat, a web-based database maintained by the National Nuclear Data Center, Brookhaven National Laboratory, Upton, NY; http://www.nndc.bnl.gov/nudat2/.
    • National Nuclear Data Center. Nuclear Data from NuDat
  • 14
    • 0023514509 scopus 로고
    • Monte Carlo evaluation of kerma at a point for photon transport problems
    • J. F. Williamson, " Monte Carlo evaluation of kerma at a point for photon transport problems., " Med. Phys. 14, 567-576 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 567-576
    • Williamson, J.F.1
  • 15
    • 3142677842 scopus 로고    scopus 로고
    • Phantom size in brachytherapy source dosimetric studies
    • J. Ṕrez-Calatayud, D. Granero, and F. Ballester, " Phantom size in brachytherapy source dosimetric studies., " Med. Phys. 31, 2075-2081 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2075-2081
    • Ṕrez-Calatayud, J.1    Granero, D.2    Ballester, F.3
  • 16
    • 0030878671 scopus 로고    scopus 로고
    • Monte Carlo calculation of dose rate distributions around Ir192 wires
    • F. Ballester, C. Hernández, J. Ṕrez-Calatayud, and F. Lliso, " Monte Carlo calculation of dose rate distributions around Ir192 wires., " Med. Phys. 24, 1221-1228 (1997).
    • (1997) Med. Phys. , vol.24 , pp. 1221-1228
    • Ballester, F.1    Hernández, C.2    Ṕrez-Calatayud, J.3    Lliso, F.4
  • 17
    • 0029038383 scopus 로고
    • Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate Ir192 sources
    • J. F. Williamson and Z. Li, " Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate Ir192 sources., " Med. Phys. 22, 809-819 (1995).
    • (1995) Med. Phys. , vol.22 , pp. 809-819
    • Williamson, J.F.1    Li, Z.2
  • 18
    • 0031120968 scopus 로고    scopus 로고
    • ROOT - An object oriented data analysis framework
    • R. Brun and F. Rademakers, " ROOT - An object oriented data analysis framework., " Nucl. Instrum. Methods Phys. Res. A 389, 81-86 (1997). (See also http://root.cern.ch)
    • (1997) Nucl. Instrum. Methods Phys. Res. a , vol.389 , pp. 81-86
    • Brun, R.1    Rademakers, F.2
  • 19
    • 0031120968 scopus 로고    scopus 로고
    • ROOT - An object oriented data analysis framework
    • See also
    • R. Brun and F. Rademakers, " ROOT - An object oriented data analysis framework., " Nucl. Instrum. Methods Phys. Res. A 389, 81-86 (1997). (See also http://root.cern.ch)
    • (1997) Nucl. Instrum. Methods Phys. Res. a , vol.389 , pp. 81-86
    • Brun, R.1    Rademakers, F.2
  • 22
    • 0033679867 scopus 로고    scopus 로고
    • Monte Carlo dosimetry of a new Ir192 high dose rate brachytherapy source
    • A. Angelopoulos, P. Baras, L. Sakelliou, P. Karaiskos, and P. Sandilos, " Monte Carlo dosimetry of a new Ir192 high dose rate brachytherapy source., " Med. Phys. 27, 2521-2526 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 2521-2526
    • Angelopoulos, A.1    Baras, P.2    Sakelliou, L.3    Karaiskos, P.4    Sandilos, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.