-
1
-
-
84890642891
-
The history of urethral catheterization
-
Medicine and Health Rhode Island
-
Patel, S.R. and Caldamone, A.A. (2004) The history of urethral catheterization, Medicine and Health Rhode Island.
-
(2004)
-
-
Patel, S.R.1
Caldamone, A.A.2
-
2
-
-
11144270855
-
Biomedical microsystems for minimally invasive diagnosis and treatment
-
Haga, Y. and Esashi, M. (2004) Biomedical microsystems for minimally invasive diagnosis and treatment, Proceedings of the IEEE, 92, 1, 98-114.
-
(2004)
Proceedings of the IEEE, 92
, vol.1
, pp. 98-114
-
-
Haga, Y.1
Esashi, M.2
-
3
-
-
21344441723
-
Visualization of a blood vessel using a micromotor
-
Salimuzzaman, M., Matani, A., Oshiro, O., et al. (1996) Visualization of a blood vessel using a micromotor, Tech. Dig. 14th Sensor Symp. 279-80.
-
(1996)
Tech. Dig. 14th Sensor Symp.
, pp. 279-280
-
-
Salimuzzaman, M.1
Matani, A.2
Oshiro, O.3
-
4
-
-
0030743664
-
Development of micro and millimotors
-
Lehr, H., Ehrfeld, W., Hagemann, B., et al. (1997) Development of micro and millimotors, Min. Invas. Ther. Allied Technol., 6, 191-4.
-
(1997)
Min. Invas. Ther. Allied Technol.
, vol.6
, pp. 191-194
-
-
Lehr, H.1
Ehrfeld, W.2
Hagemann, B.3
-
5
-
-
0023671936
-
Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope
-
Philadelphia, PA, 24-29 April
-
Ikuta, K., Tsukamoto, M. and Hirose, S. (1988) Shape memory alloy servo actuator system with electric resistance feedback and application for active endoscope, Proceedings of the IEEE International Conference on Robotics and Automation, Philadelphia, PA, 24-29 April 1988, 427-30.
-
(1988)
Proceedings of the IEEE International Conference on Robotics and Automation
, vol.1988
, pp. 427-430
-
-
Ikuta, K.1
Tsukamoto, M.2
Hirose, S.3
-
6
-
-
0345146444
-
Design of a shape memory actuated gastrointestinal intervention system
-
Bremen, Germany, 26-28 Jume
-
Reynaerts, D., Peirs, J. and Brussel, H.V. (1996) Design of a shape memory actuated gastrointestinal intervention system, Proceedings of the 5th International Conference on New Actuators, Bremen, Germany, 26-28 Jume 1996, 409-12.
-
(1996)
Proceedings of the 5th International Conference on New Actuators
, vol.1996
, pp. 409-412
-
-
Reynaerts, D.1
Peirs, J.2
Brussel, H.V.3
-
7
-
-
25144453254
-
Steerable and aimable catheter
-
US Patent 4543 090
-
McCoy, W.C. (1985) Steerable and aimable catheter, US Patent 4543 090.
-
(1985)
-
-
McCoy, W.C.1
-
8
-
-
0030147961
-
Multi freedom tube type manipulator with SMA plate
-
Kaneko, S., Aramaki, S., Arai, K., et al. (1995) Multi freedom tube type manipulator with SMA plate, J, Intell. Mat. Syst. Struc., 7, 3, 331-5.
-
(1995)
J, Intell. Mat. Syst. Struc.
, vol.7
, Issue.3
, pp. 331-335
-
-
Kaneko, S.1
Aramaki, S.2
Arai, K.3
-
9
-
-
0028603795
-
Micro Active Catheter System with Multi Degrees of Freedom
-
San Diego, California
-
Fukuda, T., Guo, S., Kosuge, K., et al. (1994) Micro Active Catheter System with Multi Degrees of Freedom, Proceedings of the IEEE International Conference on Robotic and Automation, San Diego, California, 3, 2290-5.
-
(1994)
Proceedings of the IEEE International Conference on Robotic and Automation
, vol.3
, pp. 2290-2295
-
-
Fukuda, T.1
Guo, S.2
Kosuge, K.3
-
10
-
-
9244241012
-
Artificial muscle technology: physical principles and naval prospects
-
Madden, J.D.W., Vandesteeg, N.A., Anquetil, P.A., et al. (2004) Artificial muscle technology: physical principles and naval prospects; IEEE J. Oceanic Eng., 29, 3, 706-28.
-
(2004)
IEEE J. Oceanic Eng.
, vol.29
, Issue.3
, pp. 706-728
-
-
Madden, J.D.W.1
Vandesteeg, N.A.2
Anquetil, P.A.3
-
11
-
-
0004224723
-
One-Dimensional Metals
-
Springer-Verlag, New York
-
Siegmar, R. (1995) One-Dimensional Metals, Springer-Verlag, New York.
-
(1995)
-
-
Siegmar, R.1
-
13
-
-
0030145429
-
Steerable microcatheters actuated by embedded conducting polymer structures
-
Della, A. Santa, A. Mazzoldi, D. de Rossi (1996) Steerable microcatheters actuated by embedded conducting polymer structures, J. Intelligent Mat. Syst. Struc., 7, 3, 292-300.
-
(1996)
J. Intelligent Mat. Syst. Struc.
, vol.7
, Issue.3
, pp. 292-300
-
-
Santa, D.A.1
Mazzoldi, A.2
de Rossi, D.3
-
14
-
-
0004070691
-
Conducting polymer actuators
-
PhD thesis
-
Madden, J.D. (2000) Conducting polymer actuators, PhD thesis.
-
(2000)
-
-
Madden, J.D.1
-
15
-
-
0026254046
-
New York: Optical Coherence Tomography
-
Huang, D., Swanson, E.A., Lin, C.P. (1991) New York: Optical Coherence Tomography, Science, 254, 1178.
-
(1991)
Science
, vol.254
, pp. 1178
-
-
Huang, D.1
Swanson, E.A.2
Lin, C.P.3
-
16
-
-
20344408056
-
Endoscopic Doppler optical coherence tomography: first clinical experience with a novel imaging technique
-
Yang, V.X.D., Tang, S.J., Gordon, M.L., et al. (2005) Endoscopic Doppler optical coherence tomography: first clinical experience with a novel imaging technique, Gastrointestinal Endoscopy, 61, 879-90.
-
(2005)
Gastrointestinal Endoscopy
, vol.61
, pp. 879-890
-
-
Yang, V.X.D.1
Tang, S.J.2
Gordon, M.L.3
-
17
-
-
28344431860
-
Micromachined 2-D scanner for 3-D optical coherence tomography
-
Yeow, J.T.W., Yang, V.X.D., Chahwan, A., et al. (2004) Micromachined 2-D scanner for 3-D optical coherence tomography, Sensors and Actuators, A: Physical, 117, 2, 331-40.
-
(2004)
Sensors and Actuators, A: Physical
, vol.117
, Issue.2
, pp. 331-340
-
-
Yeow, J.T.W.1
Yang, V.X.D.2
Chahwan, A.3
-
18
-
-
23044500306
-
Actuators for the cochlear implant
-
Zhou, D., Wallace, G.G., Spinks, G.M., et al. (2003) Actuators for the cochlear implant, Synth. Met., 135-136, 39-40.
-
(2003)
Synth. Met.
, vol.135-136
, pp. 39-40
-
-
Zhou, D.1
Wallace, G.G.2
Spinks, G.M.3
-
19
-
-
0029191842
-
Micro Catheter System with Active Guide Wire
-
Nagoya, Aichi, Japan
-
Gue, S., Fukunda, T., Kosuge, K., et al. (1995) Micro Catheter System with Active Guide Wire, Proceedings of the IEEE International Conference on Robotic and Automation, Nagoya, Aichi, Japan, 1, 79-84.
-
(1995)
Proceedings of the IEEE International Conference on Robotic and Automation
, vol.1
, pp. 79-84
-
-
Gue, S.1
Fukunda, T.2
Kosuge, K.3
-
20
-
-
0030387593
-
Microactive guide wire using ICPF actuator-characteristic evaluation, electrical model and operability evaluation
-
Taipei, ROC
-
Guo, S., Nakamura, T., Fukuda, T. (1996) Microactive guide wire using ICPF actuator-characteristic evaluation, electrical model and operability evaluation, Proceedings of the IEEE IECON 22nd International Conference on Industrial Electronics, Control, and Instrumentation, Taipei, ROC, 1312-7.
-
(1996)
Proceedings of the IEEE IECON 22nd International Conference on Industrial Electronics, Control, and Instrumentation
, pp. 1312-1317
-
-
Guo, S.1
Nakamura, T.2
Fukuda, T.3
-
21
-
-
0033722293
-
Bending Response of Polymer Electrolyte Actuator
-
Onishia, K., Sewa, S., Asaka, K., et al. (2000) Bending Response of Polymer Electrolyte Actuator, Proceedings of SPIE, Smart Structures and Materials, 3987, 121-8.
-
(2000)
Proceedings of SPIE, Smart Structures and Materials
, vol.3987
, pp. 121-128
-
-
Onishia, K.1
Sewa, S.2
Asaka, K.3
-
22
-
-
33846496147
-
Analysis of electro-active polymer bending: A component in a low cost ultra thin scanning endoscope
-
Yoon, W.J.,Reinhall, P.G., Seibel, E.J., Analysis of electro-active polymer bending: A component in a low cost ultra thin scanning endoscope, Sensors and Actuators: A Physical, 133, 2, 506-17, (2007).
-
(2007)
Sensors and Actuators: A Physical
, vol.133
, Issue.2
, pp. 506-517
-
-
Yoon, W.J.1
Reinhall, P.G.2
Seibel, E.J.3
-
23
-
-
0242525567
-
Tailoring actuation of ionic polymer-metal composites through cation combination
-
Nemat-Nasser, S., Wu, Y. (2003) Tailoring actuation of ionic polymer-metal composites through cation combination, Proceedings of SPIE, Smart structures and materials: electroactive polymer actuators and devices (EAPAD), 5051, 245-53.
-
(2003)
Proceedings of SPIE, Smart structures and materials: electroactive polymer actuators and devices (EAPAD)
, vol.5051
, pp. 245-253
-
-
Nemat-Nasser, S.1
Wu, Y.2
-
24
-
-
0035121211
-
The effects of counter ions on characterization and performance of a solid polymer electrolyte actuator
-
Onishi, K., Sewa, S., Asaka, K., et al. (2001) The effects of counter ions on characterization and performance of a solid polymer electrolyte actuator, Electrochim. Acta 46 (8), 1233-41.
-
(2001)
Electrochim. Acta
, vol.46
, Issue.8
, pp. 1233-1241
-
-
Onishi, K.1
Sewa, S.2
Asaka, K.3
-
25
-
-
14644437692
-
Electrostress diffusion coupling model for polyelectrolyte gels
-
Yamaue, T., Mukai, H., Asaka, K. and Doi, M. (2005) Electrostress diffusion coupling model for polyelectrolyte gels, Macromolecules, 38, 1349-56.
-
(2005)
Macromolecules
, vol.38
, pp. 1349-1356
-
-
Yamaue, T.1
Mukai, H.2
Asaka, K.3
Doi, M.4
-
26
-
-
0036030655
-
Design of Nafion actuator with enhanced displacement
-
Proceedings of SPIE 4695, Smart structures and materials 2002: electroactive polymer actuators and devices (EAPAD), 57-66
-
Uchida, M., Xu, C., Guilly, M.L. and Taya, M. (2002) Design of Nafion actuator with enhanced displacement, Proceedings of SPIE 4695, Smart structures and materials 2002: electroactive polymer actuators and devices (EAPAD), 57-66.
-
(2002)
-
-
Uchida, M.1
Xu, C.2
Guilly, M.L.3
Taya, M.4
-
27
-
-
34250193968
-
A new approach to develop ionic polymer-metal composites (IPMC) actuator Fabrication and control for active catheter systems
-
Fang, B.K., Ju, M.S., Lin, C.K. (2007) A new approach to develop ionic polymer-metal composites (IPMC) actuator Fabrication and control for active catheter systems, Sensors and Actuators: A Physical, 137, 321-9.
-
(2007)
Sensors and Actuators: A Physical
, vol.137
, pp. 321-329
-
-
Fang, B.K.1
Ju, M.S.2
Lin, C.K.3
-
28
-
-
12344268878
-
Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography
-
Yuli, W., Bachman, M., Guann-Pyng, L., et al. (2005) Low-voltage polymer-based scanning cantilever for in vivo optical coherence tomography, Optics Letters, 30, 1, 53-5.
-
(2005)
Optics Letters, 30
, vol.1
, pp. 53-55
-
-
Yuli, W.1
Bachman, M.2
Guann-Pyng, L.3
-
29
-
-
0036240736
-
Mechanical properties of mechanical actuator for treating ischemic stroke
-
Metzger, M.F., Wilson, T.S., Schumann, D., et al. (2002) Mechanical properties of mechanical actuator for treating ischemic stroke, Biomedical Microdevices, 4, 2, 89-96.
-
(2002)
Biomedical Microdevices
, vol.4
, Issue.2
, pp. 89-96
-
-
Metzger, M.F.1
Wilson, T.S.2
Schumann, D.3
-
30
-
-
0036405213
-
Laser-activated shape memory polymer microactuators for treating stroke
-
Maitland, D.J., Wilson, T., Metzger, M. and Schumann, D.L. (2002) Laser-activated shape memory polymer microactuators for treating stroke, Proceedings of SPIE (The International Society for Optical Engineering), 4626, 394-402.
-
(2002)
Proceedings of SPIE (The International Society for Optical Engineering)
, vol.4626
, pp. 394-402
-
-
Maitland, D.J.1
Wilson, T.2
Metzger, M.3
Schumann, D.L.4
-
31
-
-
3042762904
-
Design of braided composite cardiovascular catheters based on required axial, flexural, and torsional rigidities
-
Carey, J., Fahim, A. and Munro, M., (2004) Design of braided composite cardiovascular catheters based on required axial, flexural, and torsional rigidities, J. Biomed. Mat. Res.: B App, Biomat, 70, 1, 73-81.
-
(2004)
J. Biomed. Mat. Res.: B App, Biomat
, vol.70
, Issue.1
, pp. 73-81
-
-
Carey, J.1
Fahim, A.2
Munro, M.3
-
32
-
-
84890784261
-
Market for Disposable catheters and suppliers market
-
Kalorama Information. New York, NY
-
Kalorama Information. (1996) Market for Disposable catheters and suppliers market. Kalorama Information, New York, NY.
-
(1996)
Kalorama Information
-
-
-
33
-
-
84890582946
-
-
www.FDA.gov.
-
-
-
-
34
-
-
84890681486
-
The worldwide market for catheters
-
Kalorama Information, Kalorama Information, New York, NY
-
Kalorama Information. (2008) The worldwide market for catheters. Kalorama Information, New York, NY.
-
(2008)
-
-
-
35
-
-
0033685635
-
Bending, torsional and extending active catheter assembled using electroplating
-
Haga, Y., Esashi, M. and Maeda, S. (2000) Bending, torsional and extending active catheter assembled using electroplating, Proceedings of the IEEE Micro Electro Mechanical Systems (MEMS), 181-6.
-
(2000)
Proceedings of the IEEE Micro Electro Mechanical Systems (MEMS)
, pp. 181-186
-
-
Haga, Y.1
Esashi, M.2
Maeda, S.3
-
36
-
-
85046064303
-
Safe current limits for electromedical equipment and hazards to patients
-
Levin, M. (1994) Safe current limits for electromedical equipment and hazards to patients, J. Am. Heart Ass., Circulation, 2160.
-
(1994)
J. Am. Heart Ass., Circulation
, pp. 2160
-
-
Levin, M.1
-
37
-
-
0347926364
-
Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode array-a two-dimensional application of finite element analysis
-
Chen, B.K., Clark, G.M., Jones, R. (2003) Evaluation of trajectories and contact pressures for the straight nucleus cochlear implant electrode array-a two-dimensional application of finite element analysis, Medical Eng. Phys, 25 141-7.
-
(2003)
Medical Eng. Phys
, vol.25
, pp. 141-147
-
-
Chen, B.K.1
Clark, G.M.2
Jones, R.3
-
38
-
-
0030662183
-
Simulating the effect of cochlear-implant electrode insertion depth on speech understanding
-
Dormana, M.F., Loizoub, P.C. and Rainey, D. (1997) Simulating the effect of cochlear-implant electrode insertion depth on speech understanding, J. Acoust. Soc. Am., 2993.
-
(1997)
J. Acoust. Soc. Am.
, pp. 2993
-
-
Dormana, M.F.1
Loizoub, P.C.2
Rainey, D.3
-
40
-
-
35048840205
-
Polypyrrole actuator operationg voltage limits in aqueous NaPf6
-
Shoa, T., Cole, M., Yang, V. and Madden, J. (2007) Polypyrrole actuator operationg voltage limits in aqueous NaPf6, Proceedings of SPIE, Smart Structures and Materials: Electroactive Polymer Actuators and Devices, 6524, 652421.
-
(2007)
Proceedings of SPIE, Smart Structures and Materials: Electroactive Polymer Actuators and Devices
, vol.6524
, pp. 652421
-
-
Shoa, T.1
Cole, M.2
Yang, V.3
Madden, J.4
-
41
-
-
0036028329
-
Conducting polymer actuators as engineering materials
-
Madden, J.D.W., Peter, G.A. and Hunter, I.W. (2002) Conducting polymer actuators as engineering materials, Proceedings of SPIE, Smart Structures and Materials: Electroactive Polymer Actuators and Devices, 4695, 176-190.
-
(2002)
Proceedings of SPIE, Smart Structures and Materials: Electroactive Polymer Actuators and Devices
, vol.4695
, pp. 176-190
-
-
Madden, J.D.W.1
Peter, G.A.2
Hunter, I.W.3
-
42
-
-
84890656732
-
-
Actuatorweb.org.
-
-
-
-
43
-
-
0034711369
-
Microfabricating Conjugated Polymer Actuators
-
Jager, E.W.H., Smela, E. and Inganas, O. (2000) Microfabricating Conjugated Polymer Actuators, Science, 290, 1540-5.
-
(2000)
Science
, vol.290
, pp. 1540-1545
-
-
Jager, E.W.H.1
Smela, E.2
Inganas, O.3
-
44
-
-
0037450279
-
A conducting polymer artificial muscle with 12% linear strain
-
Bay, L., West, K., Sommer-Larsen, P., et al. (2003) A conducting polymer artificial muscle with 12% linear strain, Adv. Mat., 15, 310-3.
-
(2003)
Adv. Mat.
, vol.15
, pp. 310-313
-
-
Bay, L.1
West, K.2
Sommer-Larsen, P.3
-
45
-
-
14844311255
-
Free-standing polypyrrole actuators with response rate of 10.8%s-1
-
Hara, S., Zama, T., Takashima, W. and Kaneto, K. (2005) Free-standing polypyrrole actuators with response rate of 10.8%s-1, Synth. Met. 149, 199-201.
-
(2005)
Synth. Met.
, vol.149
, pp. 199-201
-
-
Hara, S.1
Zama, T.2
Takashima, W.3
Kaneto, K.4
-
46
-
-
84890659336
-
-
www.americanheart.org.
-
-
-
-
47
-
-
85046113654
-
Catheter-Based Optical Imaging of a Human Coronary Artery
-
Tearney, G.J., Brezinski, M.E., Boppart, S.A., et al. (1996) Catheter-Based Optical Imaging of a Human Coronary Artery, J. Am. Heart Ass., Circulation. 94, 3013.
-
(1996)
J. Am. Heart Ass., Circulation
, vol.94
, pp. 3013
-
-
Tearney, G.J.1
Brezinski, M.E.2
Boppart, S.A.3
-
48
-
-
42449112834
-
Electrostatic Forward-Viewing Scanning Probe for Doppler Optical Coherence Tomography using a Dissipative Polymer Catheter
-
Munce, N.R., Mariampillai, A., Standish, B., et al. (2008) Electrostatic Forward-Viewing Scanning Probe for Doppler Optical Coherence Tomography using a Dissipative Polymer Catheter, Optics Letters, 33, 7, 657-9.
-
(2008)
Optics Letters
, vol.33
, Issue.7
, pp. 657-659
-
-
Munce, N.R.1
Mariampillai, A.2
Standish, B.3
-
49
-
-
0003753264
-
Electroactive Polymer (EAP) Actuators as Artificial Muscles: Reality, Potential, and Challenges
-
2nd edn, SPIE Press Monograph
-
Cohen, Y.B, Electroactive Polymer (EAP) Actuators as Artificial Muscles: Reality, Potential, and Challenges, 2nd edn, SPIE Press Monograph Vol. PM136, (2001).
-
(2001)
, vol.136 PM
-
-
Cohen, Y.B.1
|