Volumn 139, Issue 1-3, 2010, Pages 153-158

Effective dose to patients from chest examinations with tomosynthesis

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER SIMULATION; HUMAN; METHODOLOGY; RADIATION DOSE; RADIOMETRY; RELATIVE BIOLOGIC EFFECTIVENESS; STATISTICAL MODEL; THORAX RADIOGRAPHY;

EID: 77953336493     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncq092     Document Type: Article
Times cited : (89)

References (17)
  • 1
    • 0141928682 scopus 로고    scopus 로고
    • Digital X-ray tomosynthesis: current state of the art and clinical potential
    • Dobbins, J. T. and Godfrey, D. J. Digital X-ray tomosynthesis: current state of the art and clinical potential. Phys. Med. Biol. 48, R65-R106 (2003).
    • (2003) Phys. Med. Biol. , vol.48
    • Dobbins, J.T.1    Godfrey, D.J.2
  • 2
    • 66449089773 scopus 로고    scopus 로고
    • Tomosynthesis imaging: at a translational crossroads
    • Dobbins, J. T. Tomosynthesis imaging: at a translational crossroads. Med. Phys. 36, 1956-1967 (2009).
    • (2009) Med. Phys. , vol.36 , pp. 1956-1967
    • Dobbins, J.T.1
  • 3
    • 58149198701 scopus 로고    scopus 로고
    • Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases
    • Vikgren, J., Zachrisson, S., Svalkvist, A., Johnsson, Å. A., Boijsen, M., Flinck, A., Kheddache, S. and Båth, M. Comparison of chest tomosynthesis and chest radiography for detection of pulmonary nodules: human observer study of clinical cases. Radiology 249, 1034-1041 (2008).
    • (2008) Radiology , vol.249 , pp. 1034-1041
    • Vikgren, J.1    Zachrisson, S.2    Svalkvist, A.3    Johnsson, Å.4    Boijsen, M.5    Flinck, A.6    Kheddache, S.7    Båth, M.8
  • 4
    • 44349192079 scopus 로고    scopus 로고
    • Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial
    • Dobbins, J. T., McAdams, H. P., Song, J. W., Li, C. M., Godfrey, D. J., DeLong, D. M., Paik, S. H. and Martinez-Jimenez, S. Digital tomosynthesis of the chest for lung nodule detection: interim sensitivity results from an ongoing NIH-sponsored trial. Med. Phys. 35, 2554-2557 (2008).
    • (2008) Med. Phys. , vol.35 , pp. 2554-2557
    • Dobbins, J.T.1    McAdams, H.P.2    Song, J.W.3    Li, C.M.4    Godfrey, D.J.5    DeLong, D.M.6    Paik, S.H.7    Martinez-Jimenez, S.8
  • 6
    • 72049095305 scopus 로고    scopus 로고
    • A Monte Carlo estimation of effective dose in chest tomosynthesis
    • Sabol, J. M. A Monte Carlo estimation of effective dose in chest tomosynthesis. Med. Phys. 36, 5480-5487 (2009).
    • (2009) Med. Phys. , vol.36 , pp. 5480-5487
    • Sabol, J.M.1
  • 8
    • 84992861239 scopus 로고    scopus 로고
    • Radiological protection and safety in medicine
    • International Commission on Radiological Protection, ICRP Publication 73
    • International Commission on Radiological Protection. Radiological protection and safety in medicine. ICRP Publication 73. Ann. ICRP 26(2) (1996).
    • (1996) Ann. ICRP , vol.26 , Issue.2
  • 9
    • 0003189294 scopus 로고    scopus 로고
    • On health protection of individuals against the dangers of ionising radiation in relation to medical exposure. Council Directive 97/43/Euratom
    • European Commission
    • European Commission. On health protection of individuals against the dangers of ionising radiation in relation to medical exposure. Council Directive 97/43/Euratom. Official J. Eur. Comm. L180, 22-27 (1997).
    • (1997) Official J. Eur. Comm. , vol.L180 , pp. 22-27
  • 10
    • 0003954535 scopus 로고    scopus 로고
    • European Commission, Radiation Protection 109 (Luxembourg: Office for Official Publications of the European Communities)
    • European Commission. Guidance on diagnostic reference levels for medical exposures. Radiation Protection 109 (Luxembourg: Office for Official Publications of the European Communities) (1999).
    • (1999) Guidance on diagnostic reference levels for medical exposures
  • 11
    • 77953353601 scopus 로고    scopus 로고
    • Swedish Radiation Safety Authority. Strålsäkerhetsmyndighetens föreskrifter om diagnostiska standarddoser och referensnivåer inom medicinsk röntgendiagnostik; Strålsäkerhetsmyndighetens allmänna råd om tillämpningen av föreskrifterna (SSMFS 2008: 20) om diagnostiska standarddoser och referensnivåer inom medicinsk röntgendiagnostik (in Swedish). SSMFS 2008: 20 (Stockholm: Swedish Radiation Safety Authority)
    • Swedish Radiation Safety Authority. Strålsäkerhetsmyndighetens föreskrifter om diagnostiska standarddoser och referensnivåer inom medicinsk röntgendiagnostik; Strålsäkerhetsmyndighetens allmänna råd om tillämpningen av föreskrifterna (SSMFS 2008: 20) om diagnostiska standarddoser och referensnivåer inom medicinsk röntgendiagnostik (in Swedish). SSMFS 2008: 20 (Stockholm: Swedish Radiation Safety Authority) (2008).
    • (2008)
  • 12
    • 77953337880 scopus 로고
    • International Commission on Radiological Protection, ICRP Publication 103. Ann. ICRP
    • International Commission on Radiological Protection. Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP 37(2-4) (1991).
    • (1991) Recommendations of the International Commission on Radiological Protection , vol.37 , Issue.2-4
  • 13
    • 66749105800 scopus 로고    scopus 로고
    • Investigation of the dosimetry of chest tomosynthesis
    • 725785X.1-72585X.8
    • Svalkvist, A., Zachrisson, S., Månsson, L. G. and Båth, M. Investigation of the dosimetry of chest tomosynthesis. Proc. SPIE 7258, 725785X.1-72585X.8 (2009).
    • (2009) Proc. SPIE , vol.7258
    • Svalkvist, A.1    Zachrisson, S.2    Månsson, L.G.3    Båth, M.4
  • 14
    • 77953331398 scopus 로고    scopus 로고
    • Monte Carlo simulations of the dosimetry of chest tomosynthesis
    • Epub ahead of print March 3 doi:10.1093/rpd/ncq068
    • Svalkvist, A., Månsson, L. G. and Båth, M. Monte Carlo simulations of the dosimetry of chest tomosynthesis. Radiat. Prot. Dosim. Epub ahead of print March 3 doi:10.1093/rpd/ncq068 (2010).
    • (2010) Radiat. Prot. Dosim.
    • Svalkvist, A.1    Månsson, L.G.2    Båth, M.3
  • 15
    • 73649123166 scopus 로고    scopus 로고
    • Simulation of dose reduction in tomosynthesis
    • Svalkvist, A. and Båth, M. Simulation of dose reduction in tomosynthesis. Med. Phys. 37, 258-269 (2010).
    • (2010) Med. Phys. , vol.37 , pp. 258-269
    • Svalkvist, A.1    Båth, M.2
  • 16
    • 6844240322 scopus 로고    scopus 로고
    • The radiation protection and nuclear safety authorities in Denmark, Finland, Iceland, Norway and Sweden. Report on Nordic radiation protection cooperation no. 5
    • The radiation protection and nuclear safety authorities in Denmark, Finland, Iceland, Norway and Sweden. Nordic guidance levels for patient doses in diagnostic radiology. Report on Nordic radiation protection cooperation no. 5 (1996).
    • (1996) Nordic guidance levels for patient doses in diagnostic radiology
  • 17
    • 47249166093 scopus 로고    scopus 로고
    • Effective doses in radiology and diagnostic nuclear medicine: a catalog
    • Mettler, F. R. Jr., Huda, W., Yoshizumi, T. T. and Mahesh, M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248, 254-263 (2008).
    • (2008) Radiology , vol.248 , pp. 254-263
    • Mettler F.R., Jr.1    Huda, W.2    Yoshizumi, T.T.3    Mahesh, M.4