메뉴 건너뛰기




Volumn 115, Issue 3, 2010, Pages 403-412

Three-dimensional analysis of pulmonary nodules: Variability of semiautomated volume measurements between different versions of the same software

Author keywords

3D volumetry; Multidetector CT; Pulmonary nodule

Indexed keywords

ALGORITHM; ARTICLE; AUTOMATED PATTERN RECOGNITION; COMPARATIVE STUDY; COMPUTER ASSISTED DIAGNOSIS; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; HUMAN; LUNG NODULE; LUNG TUMOR; METHODOLOGY; PATHOLOGY; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 77953233890     PISSN: 00338362     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11547-010-0511-6     Document Type: Article
Times cited : (6)

References (23)
  • 1
    • 2142697951 scopus 로고    scopus 로고
    • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?
    • Revel MP, Bissery A, Bienvenu M et al (2004) Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 231:453-458
    • (2004) Radiology , vol.231 , pp. 453-458
    • Revel, M.P.1    Bissery, A.2    Bienvenu, M.3
  • 3
    • 33947122052 scopus 로고    scopus 로고
    • Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters
    • Honda O, Sumikawa H, Johkoh T et al (2007) Computer-assisted lung nodule volumetry from multi-detector row CT: Influence of image reconstruction parameters. Eur J Radiol 62:106-113
    • (2007) Eur. J. Radiol. , vol.62 , pp. 106-113
    • Honda, O.1    Sumikawa, H.2    Johkoh, T.3
  • 4
    • 40749155455 scopus 로고    scopus 로고
    • Automated volumetry of pulmonary nodules on multidetector CT: Influence of slice thickness, reconstruction algorithm and tube current. Preliminary results
    • Larici AR, Storto ML, Torge M et al (2008) Automated volumetry of pulmonary nodules on multidetector CT: influence of slice thickness, reconstruction algorithm and tube current. Preliminary results. Radiol Med 113:29-42
    • (2008) Radiol. Med. , vol.113 , pp. 29-42
    • Larici, A.R.1    Storto, M.L.2    Torge, M.3
  • 5
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
    • de Hoop B, Gietema H, van Ginneken B et al (2008) A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 19:800-808
    • (2008) Eur. Radiol. , vol.19 , pp. 800-808
    • De Hoop, B.1    Gietema, H.2    Van Ginneken, B.3
  • 6
    • 77954457888 scopus 로고    scopus 로고
    • SyngoCT 2007S. Istruzione d'uso, Siemens Medical, Muenchen
    • Siemens Medical (2006) SyngoCT 2007S. Istruzione d'uso. Volume 4. Siemens Medical, Muenchen
    • (2006) , vol.4
    • Medical, S.1
  • 7
    • 0141841669 scopus 로고    scopus 로고
    • Detection of pulmonary nodules by multislice computed tomography: Improved detection rate with reduced slice thickness
    • Fischbach F, Knollmann F, Griesshaber V et al (2003) Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13:2378-2383
    • (2003) Eur. Radiol. , vol.13 , pp. 2378-2383
    • Fischbach, F.1    Knollmann, F.2    Griesshaber, V.3
  • 8
    • 0036190266 scopus 로고    scopus 로고
    • Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers
    • Diederich S, Wormanns D, Semik M et al (2002) Screening for early lung cancer with low-dose spiral CT: prevalence in 817 asymptomatic smokers. Radiology 222:773-781
    • (2002) Radiology , vol.222 , pp. 773-781
    • Diederich, S.1    Wormanns, D.2    Semik, M.3
  • 10
    • 0036159520 scopus 로고    scopus 로고
    • Small pulmonary nodules on CT accompanying surgically resectable lung cancer: Likelihood of malignancy
    • Kim YH, Lee KS, Primack SL et al (2002) Small pulmonary nodules on CT accompanying surgically resectable lung cancer: likelihood of malignancy. J Thorac Imaging 17:40-46
    • (2002) J. Thorac. Imaging , vol.17 , pp. 40-46
    • Kim, Y.H.1    Lee, K.S.2    Primack, S.L.3
  • 11
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: A statement from the fleischner society
    • MacMahon H, Austin J H M, Gamsu G et al (2005) Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology 237:395-400
    • (2005) Radiology , vol.237 , pp. 395-400
    • MacMahon, H.1    Austin, J.H.M.2    Gamsu, G.3
  • 12
    • 33646913058 scopus 로고    scopus 로고
    • Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements
    • Goodman LR, Gulsun M, Washington L et al (2006) Inherent variability of CT lung nodule measurements in vivo using semiautomated volumetric measurements. AJR Am J Roentgenol 186:989-994
    • (2006) AJR Am. J. Roentgenol. , vol.186 , pp. 989-994
    • Goodman, L.R.1    Gulsun, M.2    Washington, L.3
  • 13
    • 4444224070 scopus 로고    scopus 로고
    • Characterization of small pulmonary nodules by CT
    • Wormanns D, Diederich S (2004) Characterization of small pulmonary nodules by CT. Eur Radiol 14:1380-1391
    • (2004) Eur. Radiol. , vol.14 , pp. 1380-1391
    • Wormanns, D.1    Diederich, S.2
  • 14
    • 33748923799 scopus 로고    scopus 로고
    • Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    • Gietema HA, Wang Y, Xu D et al (2006) Pulmonary nodules detected at lung cancer screening: interobserver variability of semiautomated volume measurements. Radiology 241:251-257
    • (2006) Radiology , vol.241 , pp. 251-257
    • Gietema, H.A.1    Wang, Y.2    Xu, D.3
  • 15
    • 2142700841 scopus 로고    scopus 로고
    • Pulmonary nodules: Preliminary experience with three-dimensional evaluation
    • Revel MP, Lefort C, Bissery A et al (2004) Pulmonary nodules: preliminary experience with three-dimensional evaluation. Radiology 231:459-466
    • (2004) Radiology , vol.231 , pp. 459-466
    • Revel, M.P.1    Lefort, C.2    Bissery, A.3
  • 16
    • 2442639078 scopus 로고    scopus 로고
    • Lung tumor growth: Assessment with CT. Comparison of diameter and crosssectional area with volume measurements
    • Jennings SG, Winer-Muram HT, Tarver RD, Farber MO (2004) Lung tumor growth: assessment with CT. Comparison of diameter and crosssectional area with volume measurements. Radiology 231:866-871
    • (2004) Radiology , vol.231 , pp. 866-871
    • Jennings, S.G.1    Winer-Muram, H.T.2    Tarver, R.D.3    Farber, M.O.4
  • 17
    • 33747145292 scopus 로고    scopus 로고
    • Software volumetric evaluation of doubling times for differentiating benign versus malignant pulmonary nodules
    • Revel MP, Merlin A, Peyrard S et al (2006) Software volumetric evaluation of doubling times for differentiating benign versus malignant pulmonary nodules. AJR Am J Roentgenol 187:135-142
    • (2006) AJR Am. J. Roentgenol. , vol.187 , pp. 135-142
    • Revel, M.P.1    Merlin, A.2    Peyrard, S.3
  • 18
    • 77954459533 scopus 로고    scopus 로고
    • Chest Xray Doubling Time Calculator. Published June 2000, revised July 2004. Available at:, Accessed October 2009
    • Chest Xray Doubling Time Calculator. Published June 2000, revised July 2004. Available at: http://www.chestxray.com/SPN/DoublingTime.html. Accessed October 2009
  • 19
    • 36249024875 scopus 로고    scopus 로고
    • Pulmonary nodules: Interscan variability of semiautomated volume measurements with multisection CT - Influence of inspiration level, nodule size, and segmentation performance
    • Gietema HA, Schaefer-Prokop CM, Mali W P T M et al (2007) Pulmonary nodules: interscan variability of semiautomated volume measurements with multisection CT - Influence of inspiration level, nodule size, and segmentation performance. Radiology 245:888-894
    • (2007) Radiology , vol.245 , pp. 888-894
    • Gietema, H.A.1    Schaefer-Prokop, C.M.2    Mali, W.P.T.M.3
  • 20
    • 16544371693 scopus 로고    scopus 로고
    • Volumetric assessment of pulmonary nodules with ECG-gated MDCT
    • Boll DT, Gilkeson RC, Fleiter TR et al (2004) Volumetric assessment of pulmonary nodules with ECG-gated MDCT. AJR Am J Roentgenol 183:1217-1223
    • (2004) AJR Am. J. Roentgenol. , vol.183 , pp. 1217-1223
    • Boll, D.T.1    Gilkeson, R.C.2    Fleiter, T.R.3
  • 21
    • 2142812310 scopus 로고    scopus 로고
    • Small pulmonary nodules: Reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT
    • Kostis WJ, Yankelevitz DF, Reeves AP et al (2004) Small pulmonary nodules: reproducibility of three-dimensional volumetric measurement and estimation of time to follow-up CT. Radiology 231:446-452
    • (2004) Radiology , vol.231 , pp. 446-452
    • Kostis, W.J.1    Yankelevitz, D.F.2    Reeves, A.P.3
  • 22
    • 49049092638 scopus 로고    scopus 로고
    • Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program
    • Wang Y, van Klaveren RJ, van der Zaag-Loonen HJ et al (2008) Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program. Radiology 248:625-631
    • (2008) Radiology , vol.248 , pp. 625-631
    • Wang, Y.1    Van Klaveren, R.J.2    Van Der Zaag-Loonen, H.J.3
  • 23
    • 33846527920 scopus 로고    scopus 로고
    • Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology
    • Petrou M, Quint LE, Nan B, Baker LH (2007) Pulmonary nodule volumetric measurement variability as a function of CT slice thickness and nodule morphology. AJR Am J Roentgenol 188:306-312
    • (2007) AJR Am. J. Roentgenol. , vol.188 , pp. 306-312
    • Petrou, M.1    Quint, L.E.2    Nan, B.3    Baker, L.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.