메뉴 건너뛰기




Volumn 48, Issue 6, 2010, Pages 795-803

Traceability of values for catalytic activity concentration of enzymes: A certified reference material for aspartate transaminase

(18)  Toussaint, Brigitte a   Emons, Hendrik a   Schimmel, Heinz G a   Bossert Reuther, Steffen b   Canalias, Francesca c   Ceriotti, Ferruccio d   Férard, Georges e   Ferrero, Carlo A d   Franck, Paul F H f   Gella, F Javier g   Henny, Joseph h   Jørgensen, Poul J i   Klauke, Rainer j   Lessinger, Jean Marc k   Mazziotta, Daniel l   Panteghini, Mauro m   Ueda, Shigeru n   Schumann, Gerhard j  


Author keywords

Aspartate aminotransferase; Aspartate transaminase; Certified Reference Material; IFCC reference measurement procedure; Traceability

Indexed keywords

2 OXOGLUTARATE AMINOTRANSFERASE; ASPARTATE AMINOTRANSFERASE; ASPARTIC ACID; BOVINE SERUM ALBUMIN; BUFFER; RECOMBINANT ENZYME; UNCLASSIFIED DRUG;

EID: 77953182130     PISSN: 14346621     EISSN: 14374331     Source Type: Journal    
DOI: 10.1515/CCLM.2010.146     Document Type: Article
Times cited : (8)

References (28)
  • 2
    • 18444416347 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic concentrations of enzymes: The new concept
    • Lorentz K. IFCC primary reference procedures for the measurement of catalytic concentrations of enzymes: the new concept. Clin Chem Lab Med 2002;40:549.
    • (2002) Clin Chem Lab Med , vol.40 , pp. 549
    • Lorentz, K.1
  • 3
    • 33644820364 scopus 로고    scopus 로고
    • Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration material
    • Canalias F, Camprubí S, Sánchez M, Gella FJ. Metrological traceability of values for catalytic concentration of enzymes assigned to a calibration material. Clin Chem Lab Med 2006; 44:333-339
    • (2006) Clin Chem Lab Med , vol.44 , pp. 333-339
    • Canalias, F.1    Camprubí, S.2    Sánchez, M.3    Gella, F.J.4
  • 6
    • 0032146055 scopus 로고    scopus 로고
    • Impact of reference materials on accuracy in clinical chemistry
    • Franzini C, Ceriotti F. Impact of reference materials on accuracy in clinical chemistry. Clin Biochem 1998;31:449-457
    • (1998) Clin Biochem , vol.31 , pp. 449-457
    • Franzini, C.1    Ceriotti, F.2
  • 7
    • 60949093988 scopus 로고    scopus 로고
    • Traceability as a unique tool to improve standardization in laboratory medicine
    • Panteghini M. Traceability as a unique tool to improve standardization in laboratory medicine. Clin Biochem 2009;42: 236-240
    • (2009) Clin Biochem , vol.42 , pp. 236-240
    • Panteghini, M.1
  • 9
    • 18444372349 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes
    • Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 1. The concept of reference procedures for the measurement of catalytic activity concentrations of enzymes. Clin Chem Lab Med 2002;40:631-634
    • (2002) Clin Chem Lab Med , vol.40 , pp. 631-634
    • Siekmann, L.1    Bonora, R.2    Burtis, C.A.3    Ceriotti, F.4    Clerc-Renaud, P.5    Férard, G.6
  • 10
    • 1842857644 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 5. Reference procedure for the measurement of catalytic activity concentration of aspartate aminotransferase
    • Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Franck PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 5. Reference procedure for the measurement of catalytic activity concentration of aspartate aminotransferase. Clin Chem Lab Med 2002;40:725-733
    • (2002) Clin Chem Lab Med , vol.40 , pp. 725-733
    • Schumann, G.1    Bonora, R.2    Ceriotti, F.3    Férard, G.4    Ferrero, C.A.5    Franck, P.F.6
  • 11
    • 0036367977 scopus 로고    scopus 로고
    • IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 7. Certification of four reference materials for the determination of enzymatic activity of g-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase according to IFCC reference procedures at 378C
    • Siekmann L, Bonora R, Burtis CA, Ceriotti F, Clerc-Renaud P, Férard G, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 378C. Part 7. Certification of four reference materials for the determination of enzymatic activity of g-glutamyltransferase, lactate dehydrogenase, alanine aminotransferase and creatine kinase according to IFCC reference procedures at 378C. Clin Chem Lab Med 2002;40:739-745
    • (2002) Clin Chem Lab Med , vol.40 , pp. 739-745
    • Siekmann, L.1    Bonora, R.2    Burtis, C.A.3    Ceriotti, F.4    Clerc-Renaud, P.5    Férard, G.6
  • 14
    • 4244182254 scopus 로고    scopus 로고
    • Commutability of two AST candidate reference materials: An essential property for their use as calibrators
    • Férard G, Ceriotti F, Schumann G, Lessinger JM, Panteghini M, Ferrero C. Commutability of two AST candidate reference materials: an essential property for their use as calibrators. Clin Chem Lab Med 1999;37(Suppl):S113.
    • (1999) Clin Chem Lab Med , vol.37 , Issue.SUPPL.
    • Férard, G.1    Ceriotti, F.2    Schumann, G.3    Lessinger, J.M.4    Panteghini, M.5    Ferrero, C.6
  • 17
    • 67650890638 scopus 로고    scopus 로고
    • Evaluation of measurement data - Guide to the expression of uncertainty in measurement
    • available at
    • Evaluation of measurement data - guide to the expression of uncertainty in measurement, JCGM 100:2008 (available at www.bipm.org).
    • (2008) JCGM , vol.100
  • 18
    • 0032145170 scopus 로고    scopus 로고
    • Interassay calibration as a major contribution to the comparability of results in clinical enzymology
    • Férard G, Edwards J, Kanno T, Lessinger JM, Moss DW, Schiele F, et al. Interassay calibration as a major contribution to the comparability of results in clinical enzymology. Clin Biochem 1998;31:489-494
    • (1998) Clin Biochem , vol.31 , pp. 489-494
    • Férard, G.1    Edwards, J.2    Kanno, T.3    Lessinger, J.M.4    Moss, D.W.5    Schiele, F.6
  • 19
    • 17144394483 scopus 로고    scopus 로고
    • Standardization in laboratory medicine: New challenges
    • Panteghini M, Forest JC. Standardization in laboratory medicine: new challenges. Clin Chim Acta 2005;355:1-12.
    • (2005) Clin Chim Acta , vol.355 , pp. 1-12
    • Panteghini, M.1    Forest, J.C.2
  • 20
    • 77953228306 scopus 로고    scopus 로고
    • ISO 15195:2003. Laboratory medicine - requirements for reference measurements laboratories. Geneva, Switzerland: ISO
    • ISO 15195:2003. Laboratory medicine - requirements for reference measurements laboratories. Geneva, Switzerland: ISO.
  • 21
    • 0027418257 scopus 로고
    • Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol
    • Eckfeldt JH, Copeland KR. Accuracy verification and identification of matrix effects. The College of American Pathologists' Protocol. Arch Pathol Lab Med 1993;117:381-386
    • (1993) Arch Pathol Lab Med , vol.117 , pp. 381-386
    • Eckfeldt, J.H.1    Copeland, K.R.2
  • 23
    • 0001573172 scopus 로고    scopus 로고
    • Mechanisms of protein stabilization during freezedrying and storage: The relative importance of thermodynamic stabilization and glassy state relaxation dynamics
    • Rey L, May JC, editors. New York: Marcel Dekker
    • Pikal MJ. Mechanisms of protein stabilization during freezedrying and storage: the relative importance of thermodynamic stabilization and glassy state relaxation dynamics. In: Rey L, May JC, editors. Freeze-drying/lyophilisation of pharmaceutical and biological products. New York: Marcel Dekker, 1999:161-198
    • (1999) Freeze-drying/lyophilisation of Pharmaceutical and Biological Products , pp. 161-198
    • Pikal, M.J.1
  • 27
    • 0032145967 scopus 로고    scopus 로고
    • Criteria for the certification of internationally acceptable reference materials
    • Pauwels J, Schimmel H, Lamberty A. Criteria for the certification of internationally acceptable reference materials. Clin Biochem 1998;31:437-439
    • (1998) Clin Biochem , vol.31 , pp. 437-439
    • Pauwels, J.1    Schimmel, H.2    Lamberty, A.3
  • 28
    • 77953188274 scopus 로고    scopus 로고
    • Certification of the catalytic activity concentration of aspartate transaminase, Certified Reference Material ERM-AD457/IFCC
    • European Communities, Luxembourg, ISBN 978-92-79-12206-4
    • Toussaint B, Schumann G, Klauke R, Meeus N, Zeleny R, Trapmann S, et al. Certification of the catalytic activity concentration of aspartate transaminase, Certified Reference Material ERM-AD457/IFCC. EUR 23808 EN, European Communities, Luxembourg, 2009, ISBN 978-92-79-12206-4.
    • (2009) EUR 23808 en
    • Toussaint, B.1    Schumann, G.2    Klauke, R.3    Meeus, N.4    Zeleny, R.5    Trapmann, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.