T2-enhanced tensor diffusion trace-weighted image in the detection of hyper-acute cerebral infarction: Comparison with isotropic diffusion-weighted image

Author keywords

Acute cerebral infarction; Tensor diffusion trace weighted imaging

Indexed keywords

ACUTE CEREBRAL INFARCTION; ACUTE ISCHEMIC STROKE; ACUTE STROKE; B VALUE; CEREBRAL INFARCTION; CONSPICUITY; CONTRAST TO NOISE RATIO; DIFFUSION WEIGHTED IMAGES; ENHANCED DIFFUSION; ISOTROPIC DIFFUSION; STROKE LESIONS;

EID: 77952881987     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2009.04.023     Document Type: Article
Times cited : (10)

References (24)
  • 1
    • 0344766121 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging: diagnostic accuracy in patients imaged within 6 h of stroke symptom onset
    • Gonzalez R.G., Schaefer P.W., Buonanno F.S., et al. Diffusion-weighted MR imaging: diagnostic accuracy in patients imaged within 6 h of stroke symptom onset. Radiology 210 (1999) 155-162
    • (1999) Radiology , vol.210 , pp. 155-162
    • Gonzalez, R.G.1    Schaefer, P.W.2    Buonanno, F.S.3
  • 3
    • 0026761501 scopus 로고
    • Fast magnetic-resonance diffusion-weighted imaging of acute human stroke
    • Warach S., Chien D., Li W., Ronthal M., and Edelman R.R. Fast magnetic-resonance diffusion-weighted imaging of acute human stroke. Neurology 42 (1992) 1717-1723
    • (1992) Neurology , vol.42 , pp. 1717-1723
    • Warach, S.1    Chien, D.2    Li, W.3    Ronthal, M.4    Edelman, R.R.5
  • 4
    • 33646707301 scopus 로고    scopus 로고
    • MR diffusion-weighted imaging and outcome prediction after ischemic stroke
    • Hand P.J., Wardlaw J.M., Rivers C.S., et al. MR diffusion-weighted imaging and outcome prediction after ischemic stroke. Neurology 66 (2006) 1159-1163
    • (2006) Neurology , vol.66 , pp. 1159-1163
    • Hand, P.J.1    Wardlaw, J.M.2    Rivers, C.S.3
  • 5
    • 12344336382 scopus 로고    scopus 로고
    • Acute and subacute ischemic stroke at high-field-strength (30-T) diffusion-weighted MR imaging: intraindividual comparative study
    • Kuhl C.K., Textor J., Gieseke I., et al. Acute and subacute ischemic stroke at high-field-strength (30-T) diffusion-weighted MR imaging: intraindividual comparative study. Radiology 234 (2005) 509-516
    • (2005) Radiology , vol.234 , pp. 509-516
    • Kuhl, C.K.1    Textor, J.2    Gieseke, I.3
  • 8
    • 0036238190 scopus 로고    scopus 로고
    • Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke
    • Pereira R.S., Harris A.D., Sevick R.J., and Frayne R. Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke. Journal of Magnetic Resonance Imaging 15 (2002) 591-596
    • (2002) Journal of Magnetic Resonance Imaging , vol.15 , pp. 591-596
    • Pereira, R.S.1    Harris, A.D.2    Sevick, R.J.3    Frayne, R.4
  • 9
    • 0031658306 scopus 로고    scopus 로고
    • Mali WPTM. Diffusion-weighted magnetic resonance imaging in acute stroke
    • van Everdingen K.J., van der Grond J., Kappelle L.J., and Ramos L.M.P. Mali WPTM. Diffusion-weighted magnetic resonance imaging in acute stroke. Stroke 29 (1998) 1783-1790
    • (1998) Stroke , vol.29 , pp. 1783-1790
    • van Everdingen, K.J.1    van der Grond, J.2    Kappelle, L.J.3    Ramos, L.M.P.4
  • 10
    • 0028830962 scopus 로고
    • Acute human stroke studied by whole-brain echo-planar diffusion-weighted magnetic-resonance-imaging
    • Warach S., Gaa J., Siewert B., Wielopolski P., and Edelman R.R. Acute human stroke studied by whole-brain echo-planar diffusion-weighted magnetic-resonance-imaging. Annals of Neurology 37 (1995) 231-241
    • (1995) Annals of Neurology , vol.37 , pp. 231-241
    • Warach, S.1    Gaa, J.2    Siewert, B.3    Wielopolski, P.4    Edelman, R.R.5
  • 11
    • 0032470827 scopus 로고    scopus 로고
    • Diffusion-weighted MR of acute cerebral infarction: comparison of data processing methods
    • Chong J.N., Lu D.F., Aragao F., et al. Diffusion-weighted MR of acute cerebral infarction: comparison of data processing methods. American Journal of Neuroradiology 19 (1998) 1733-1739
    • (1998) American Journal of Neuroradiology , vol.19 , pp. 1733-1739
    • Chong, J.N.1    Lu, D.F.2    Aragao, F.3
  • 12
    • 0033824229 scopus 로고    scopus 로고
    • False-negative diffusion-weighted MR findings in acute ischemic stroke
    • Oppenheim C., Stanescu R., Dormont D., et al. False-negative diffusion-weighted MR findings in acute ischemic stroke. American Journal of Neuroradiology 21 (2000) 1434-1440
    • (2000) American Journal of Neuroradiology , vol.21 , pp. 1434-1440
    • Oppenheim, C.1    Stanescu, R.2    Dormont, D.3
  • 13
    • 0344175826 scopus 로고    scopus 로고
    • Negative diffusion-weighted MR imaging (DWI) with stroke-like focal deficits
    • Ay H., Buonanno F.S., Sorenson G., et al. Negative diffusion-weighted MR imaging (DWI) with stroke-like focal deficits. Stroke 29 (1998) 307-1307
    • (1998) Stroke , vol.29 , pp. 307-1307
    • Ay, H.1    Buonanno, F.S.2    Sorenson, G.3
  • 14
    • 77952876561 scopus 로고    scopus 로고
    • Early negative diffusion MRI (DWI) in ischemic vertebro-basilar stroke
    • Crozier S., Oppenheim C., Stanescu R., et al. Early negative diffusion MRI (DWI) in ischemic vertebro-basilar stroke. Neurology 54 (2000) A94-A194
    • (2000) Neurology , vol.54
    • Crozier, S.1    Oppenheim, C.2    Stanescu, R.3
  • 16
    • 0037380250 scopus 로고    scopus 로고
    • Acute stroke syndrome with fixed neurological deficit and false-negative diffusion-weighted imaging
    • Wei W., Goldstein S., Scheuer M.L., and Branstetter B.F. Acute stroke syndrome with fixed neurological deficit and false-negative diffusion-weighted imaging. Journal of Neuroimaging 13 (2003) 158-161
    • (2003) Journal of Neuroimaging , vol.13 , pp. 158-161
    • Wei, W.1    Goldstein, S.2    Scheuer, M.L.3    Branstetter, B.F.4
  • 17
    • 0033740222 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of suspected brain infarction
    • Meyer J.R., Gutierrez A., Mock B., et al. High-b-value diffusion-weighted MR imaging of suspected brain infarction. American Journal of Neuroradiology 21 (2000) 1821-1829
    • (2000) American Journal of Neuroradiology , vol.21 , pp. 1821-1829
    • Meyer, J.R.1    Gutierrez, A.2    Mock, B.3
  • 18
    • 0033730472 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of adult brain: image contrast and apparent diffusion coefficient map features
    • DeLano M.C., Cooper T.G., Siebert J.E., Potchen M.J., and Kuppusamy K. High-b-value diffusion-weighted MR imaging of adult brain: image contrast and apparent diffusion coefficient map features. American Journal of Neuroradiology 21 (2000) 1830-1836
    • (2000) American Journal of Neuroradiology , vol.21 , pp. 1830-1836
    • DeLano, M.C.1    Cooper, T.G.2    Siebert, J.E.3    Potchen, M.J.4    Kuppusamy, K.5
  • 20
    • 30144439076 scopus 로고    scopus 로고
    • Early detection of global cerebral anoxia: improved accuracy by high-b-value diffusion-weighted imaging with long echo time
    • Tha K.K., Terae S., Yamamoto T., et al. Early detection of global cerebral anoxia: improved accuracy by high-b-value diffusion-weighted imaging with long echo time. American Journal of Neuroradiology 26 (2005) 1487-1497
    • (2005) American Journal of Neuroradiology , vol.26 , pp. 1487-1497
    • Tha, K.K.1    Terae, S.2    Yamamoto, T.3
  • 21
    • 0031030072 scopus 로고    scopus 로고
    • Spreading of vasogenic edema and cytotoxic edema assessed by quantitative diffusion and T2 magnetic resonance imaging
    • Loubinoux I., Volk A., Borredon J., et al. Spreading of vasogenic edema and cytotoxic edema assessed by quantitative diffusion and T2 magnetic resonance imaging. Stroke 28 (1997) 419-426
    • (1997) Stroke , vol.28 , pp. 419-426
    • Loubinoux, I.1    Volk, A.2    Borredon, J.3
  • 22
    • 34748830370 scopus 로고    scopus 로고
    • 3-Tesla versus 1.5-Tesla magnetic resonance diffusion and perfusion imaging in hyperacute ischemic stroke
    • Kosior R., Wright C., Kosior J., et al. 3-Tesla versus 1.5-Tesla magnetic resonance diffusion and perfusion imaging in hyperacute ischemic stroke. Cerebrovascular Diseases 24 (2007) 361-368
    • (2007) Cerebrovascular Diseases , vol.24 , pp. 361-368
    • Kosior, R.1    Wright, C.2    Kosior, J.3
  • 23
    • 0036238190 scopus 로고    scopus 로고
    • Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke
    • Pereira R., Harris A., Sevick R., et al. Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischemic stroke. Journal of Magnetic Resonance Imaging 5 (2002) 591-596
    • (2002) Journal of Magnetic Resonance Imaging , vol.5 , pp. 591-596
    • Pereira, R.1    Harris, A.2    Sevick, R.3
  • 24
    • 0036314446 scopus 로고    scopus 로고
    • Effect of intravenous gadolinium-DTPA on diffusion-weighted images
    • Yamada K., Kubota H., Kizu O., et al. Effect of intravenous gadolinium-DTPA on diffusion-weighted images. Stroke 33 (2002) 1799-1802
    • (2002) Stroke , vol.33 , pp. 1799-1802
    • Yamada, K.1    Kubota, H.2    Kizu, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.