메뉴 건너뛰기




Volumn 26, Issue 6, 2005, Pages 1487-1497

Early detection of global cerebral anoxia: Improved accuracy by high-b-value diffusion-weighted imaging with long echo time

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AREA UNDER THE CURVE; ARTICLE; BRAIN HYPOXIA; CARDIOPULMONARY ARREST; CONTROLLED STUDY; DEMOGRAPHY; DIAGNOSTIC ACCURACY; DIFFUSION COEFFICIENT; DIFFUSION WEIGHTED IMAGING; EARLY DIAGNOSIS; FEMALE; HUMAN; MALE; PARENCHYMA; PROGNOSIS; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; SIGNAL TRANSDUCTION; MIDDLE AGED; REPRODUCIBILITY;

EID: 30144439076     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (29)

References (27)
  • 3
    • 0036270176 scopus 로고    scopus 로고
    • S-100 protein as early predictor of regaining consciousness after out of hospital cardiac arrest
    • Hachini-Idrissi S, der Auwera MV, Schiettecatte J, et al. S-100 protein as early predictor of regaining consciousness after out of hospital cardiac arrest. Resuscitation 2002;53:251-257
    • (2002) Resuscitation , vol.53 , pp. 251-257
    • Hachini-Idrissi, S.1    Der Auwera, M.V.2    Schiettecatte, J.3
  • 4
    • 1442309702 scopus 로고    scopus 로고
    • Is this patient dead, vegetative, or severely neurologically impaired? Assessing outcome for comatose survivors of cardiac arrest
    • Booth CM, Boone RH, Tomlinson G, Detsky AS. Is this patient dead, vegetative, or severely neurologically impaired? Assessing outcome for comatose survivors of cardiac arrest. JAMA 2004;291:870-879
    • (2004) JAMA , vol.291 , pp. 870-879
    • Booth, C.M.1    Boone, R.H.2    Tomlinson, G.3    Detsky, A.S.4
  • 5
    • 0034542077 scopus 로고    scopus 로고
    • Does diffusion-weighted magnetic resonance imaging enable detection of early ischaemic change following transient cerebral ischemia?
    • Kawahara H, Takeda Y, Tanaka A, et al. Does diffusion-weighted magnetic resonance imaging enable detection of early ischaemic change following transient cerebral ischemia? J Neurol Sci 2000;181:73-81
    • (2000) J Neurol Sci , vol.181 , pp. 73-81
    • Kawahara, H.1    Takeda, Y.2    Tanaka, A.3
  • 6
    • 0033752102 scopus 로고    scopus 로고
    • Diffusion-weighted MR imaging of the brain
    • Schafer PW, Grant PE, Gonzalez RG. Diffusion-weighted MR imaging of the brain. Radiology 2000;217:331-345
    • (2000) Radiology , vol.217 , pp. 331-345
    • Schafer, P.W.1    Grant, P.E.2    Gonzalez, R.G.3
  • 7
    • 0035034310 scopus 로고    scopus 로고
    • Highly diffusion-sensitized MRI of brain: Dissociation of gray and white matter
    • Yoshiura T, Wu O, Zaheer A, et al. Highly diffusion-sensitized MRI of brain: dissociation of gray and white matter. Magn Reson Med 2001;45:734-740
    • (2001) Magn Reson Med , vol.45 , pp. 734-740
    • Yoshiura, T.1    Wu, O.2    Zaheer, A.3
  • 8
    • 0033730472 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of adult brain: Image contrast and apparent diffusion coefficient map features
    • DeLano MC, Cooper TG, Siebert JE, et al. High-b-value diffusion-weighted MR imaging of adult brain: image contrast and apparent diffusion coefficient map features. AJNR Am J Neuroradiol 2000;21:1830-1836
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1830-1836
    • DeLano, M.C.1    Cooper, T.G.2    Siebert, J.E.3
  • 10
    • 0035957106 scopus 로고    scopus 로고
    • MRI identification of early white matter injury in anoxic-ischemic encephalopathy
    • Chalela JA, Wolf RL, Maldjian JA, Kasner SE. MRI identification of early white matter injury in anoxic-ischemic encephalopathy. Neurology 2001;56:481-485
    • (2001) Neurology , vol.56 , pp. 481-485
    • Chalela, J.A.1    Wolf, R.L.2    Maldjian, J.A.3    Kasner, S.E.4
  • 11
    • 3342959131 scopus 로고    scopus 로고
    • Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence
    • Tyler DJ, Moore RJ, Marciani L, Gowland PA. Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence. Magn Reson Imaging 2004;22:1031-1037
    • (2004) Magn Reson Imaging , vol.22 , pp. 1031-1037
    • Tyler, D.J.1    Moore, R.J.2    Marciani, L.3    Gowland, P.A.4
  • 12
    • 0034025729 scopus 로고    scopus 로고
    • Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: Comparison of echo-planar, HASTE, and spin-echo sequences
    • Abe Y, Yamashita Y, Tang Y, et al. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: comparison of echo-planar, HASTE, and spin-echo sequences. Radiat Med 2000;18:7-14
    • (2000) Radiat Med , vol.18 , pp. 7-14
    • Abe, Y.1    Yamashita, Y.2    Tang, Y.3
  • 15
    • 0033740222 scopus 로고    scopus 로고
    • High-b-value diffusion-weighted MR imaging of suspected brain infarction
    • Meyer RJ, Gutierrez A, Mock B, et al. High-b-value diffusion-weighted MR imaging of suspected brain infarction. AJNR Am J Neuroradiol 2000;21:1821-1829
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 1821-1829
    • Meyer, R.J.1    Gutierrez, A.2    Mock, B.3
  • 16
    • 0036656564 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of cerebral infarctions: Are higher B values better?
    • Burdette JH, Elster AD. Diffusion-weighted imaging of cerebral infarctions: are higher B values better? J Comput Assist Tomogr 2002;26:622-627
    • (2002) J Comput Assist Tomogr , vol.26 , pp. 622-627
    • Burdette, J.H.1    Elster, A.D.2
  • 18
    • 0036238190 scopus 로고    scopus 로고
    • Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischaemic stroke
    • Pereira RS, Harris AD, Sevick RJ, Frayne R. Effect of b value on contrast during diffusion-weighted magnetic resonance imaging assessment of acute ischaemic stroke. J Magn Reson Imaging 2002;15:591-596
    • (2002) J Magn Reson Imaging , vol.15 , pp. 591-596
    • Pereira, R.S.1    Harris, A.D.2    Sevick, R.J.3    Frayne, R.4
  • 19
    • 33646711346 scopus 로고    scopus 로고
    • Comparison of apparent diffusion coefficients (ADCs) between two-point and multi-point analyses using high-b-value diffusion MR imaging
    • Kubo H, Maeda M, Araki A. Comparison of apparent diffusion coefficients (ADCs) between two-point and multi-point analyses using high-b-value diffusion MR imaging. Jpn J Radiol Technol 2001;57:634-638
    • (2001) Jpn J Radiol Technol , vol.57 , pp. 634-638
    • Kubo, H.1    Maeda, M.2    Araki, A.3
  • 20
    • 0036135414 scopus 로고    scopus 로고
    • High b-value q-space analyzed diffusion-weighted MRI: Application to multiple sclerosis
    • Assaf Y, Ben-Bashat D, Chapman J, et al. High b-value q-space analyzed diffusion-weighted MRI: application to multiple sclerosis. Magn Reson Med 2002;47:115-126
    • (2002) Magn Reson Med , vol.47 , pp. 115-126
    • Assaf, Y.1    Ben-Bashat, D.2    Chapman, J.3
  • 21
    • 0037445195 scopus 로고    scopus 로고
    • Early detection of response to radiation therapy in patients with brain malignancies using conventional and high b-value diffusion-weighted magnetic resonance imaging
    • Mardor Y, Pfeffer R, Spiegelmann R, et al. Early detection of response to radiation therapy in patients with brain malignancies using conventional and high b-value diffusion-weighted magnetic resonance imaging. J Clin Oncol 2003;21:1094-1100
    • (2003) J Clin Oncol , vol.21 , pp. 1094-1100
    • Mardor, Y.1    Pfeffer, R.2    Spiegelmann, R.3
  • 23
    • 10744231603 scopus 로고    scopus 로고
    • The existence of biexponential signal decay in magnetic resonance diffusion-weighted imaging appears to be independent of compartmentalization
    • Schwarcz A, Bogner P, Meric P, et al. The existence of biexponential signal decay in magnetic resonance diffusion-weighted imaging appears to be independent of compartmentalization. Magn Reson Med 2004;51:278-285
    • (2004) Magn Reson Med , vol.51 , pp. 278-285
    • Schwarcz, A.1    Bogner, P.2    Meric, P.3
  • 24
    • 3042740598 scopus 로고    scopus 로고
    • Extracellular superoxide concentration increases following cerebral hypoxia but does not affect cerebral blood flow
    • Fabian RH, Perez-Polo JR, Kent TA. Extracellular superoxide concentration increases following cerebral hypoxia but does not affect cerebral blood flow. Int J Devl Neurosci 2004;22:225-230
    • (2004) Int J Devl Neurosci , vol.22 , pp. 225-230
    • Fabian, R.H.1    Perez-Polo, J.R.2    Kent, T.A.3
  • 26
    • 0031595078 scopus 로고    scopus 로고
    • Diffusional anisotropy of T2 components in bovine optic nerve
    • Stanisz GJ, Henkelman RM. Diffusional anisotropy of T2 components in bovine optic nerve. Magn Reson Med 1998;40:405-410
    • (1998) Magn Reson Med , vol.40 , pp. 405-410
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 27
    • 0036087970 scopus 로고    scopus 로고
    • Biexponential T2 relaxation time analysis of the brain: Correlation with magnetization transfer ratio
    • Papanikolaou N, Maniatis V, Pappas J, et al. Biexponential T2 relaxation time analysis of the brain: correlation with magnetization transfer ratio. Invest Radiol 2002;37:363-367
    • (2002) Invest Radiol , vol.37 , pp. 363-367
    • Papanikolaou, N.1    Maniatis, V.2    Pappas, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.