메뉴 건너뛰기




Volumn 74, Issue 3, 2010, Pages 500-507

Effect of reconstruction algorithm on image quality and identification of ground-glass opacities and partly solid nodules on low-dose thin-section CT: Experimental study using chest phantom

Author keywords

High resolution CT; Lung; Radiation dose; Reconstruction algorithm

Indexed keywords

AREA UNDER THE CURVES; CHEST CT; CHEST PHANTOM; DATA SETS; EXPERIMENTAL STUDIES; GROUND-GLASS OPACITY; HIGH RESOLUTION; HIGH RESOLUTION CT; KAPPA VALUES; LOW DOSE; LOW-DOSE CT; RADIATION DOSE RECONSTRUCTION; RECONSTRUCTION ALGORITHMS; ROC ANALYSIS; THIN-SECTION CT; TUBE CURRENTS;

EID: 77952877597     PISSN: 0720048X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ejrad.2009.03.013     Document Type: Article
Times cited : (8)

References (20)
  • 1
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • Sone S., Takashima S., Li F., et al. Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 351 9111 (1998) 1242-1245
    • (1998) Lancet , vol.351 , Issue.9111 , pp. 1242-1245
    • Sone, S.1    Takashima, S.2    Li, F.3
  • 2
    • 17744365185 scopus 로고    scopus 로고
    • Early lung cancer action project: a summary of the findings on baseline screening
    • Henschke C.I., McCauley D.I., Yankelevitz D.F., et al. Early lung cancer action project: a summary of the findings on baseline screening. Oncologist 6 2 (2001) 147-152
    • (2001) Oncologist , vol.6 , Issue.2 , pp. 147-152
    • Henschke, C.I.1    McCauley, D.I.2    Yankelevitz, D.F.3
  • 3
    • 0036088169 scopus 로고    scopus 로고
    • Detection of lung cancer on chest radiographs: analysis on the basis of size and extent of ground-glass opacity at thin-section CT
    • Tsubamoto M., Kuriyama K., Kido S., et al. Detection of lung cancer on chest radiographs: analysis on the basis of size and extent of ground-glass opacity at thin-section CT. Radiology 224 1 (2002) 139-144
    • (2002) Radiology , vol.224 , Issue.1 , pp. 139-144
    • Tsubamoto, M.1    Kuriyama, K.2    Kido, S.3
  • 4
    • 0036784139 scopus 로고    scopus 로고
    • CT screening for lung cancer
    • Swensen S.J. CT screening for lung cancer. Am J Roentgenol 179 4 (2002) 833-836
    • (2002) Am J Roentgenol , vol.179 , Issue.4 , pp. 833-836
    • Swensen, S.J.1
  • 5
    • 33750315764 scopus 로고    scopus 로고
    • International early lung cancer action program investigators. Survival of patients with stage I lung cancer detected on CT screening
    • Henschke C.I., Yankelevitz D.F., Libby D.M., et al. International early lung cancer action program investigators. Survival of patients with stage I lung cancer detected on CT screening. N Engl J Med 355 17 (2006) 1763-1771
    • (2006) N Engl J Med , vol.355 , Issue.17 , pp. 1763-1771
    • Henschke, C.I.1    Yankelevitz, D.F.2    Libby, D.M.3
  • 6
    • 27144449606 scopus 로고    scopus 로고
    • Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society
    • MacMahon H., Austin J.H., Gamsu G., et al. Guidelines for management of small pulmonary nodules detected on CT scans: a statement from the Fleischner Society. Radiology 237 2 (2005) 395-400
    • (2005) Radiology , vol.237 , Issue.2 , pp. 395-400
    • MacMahon, H.1    Austin, J.H.2    Gamsu, G.3
  • 7
    • 0032793947 scopus 로고    scopus 로고
    • Ground-glass opacity on thin-section CT: value in differentiating subtypes of adenocarcinoma of the lung
    • Kuriyama K., Seto M., Kasugai T., et al. Ground-glass opacity on thin-section CT: value in differentiating subtypes of adenocarcinoma of the lung. Am J Roentgenol 173 2 (1999) 465-469
    • (1999) Am J Roentgenol , vol.173 , Issue.2 , pp. 465-469
    • Kuriyama, K.1    Seto, M.2    Kasugai, T.3
  • 8
    • 0038037974 scopus 로고    scopus 로고
    • Radiation exposure at chest CT: a statement of the Fleischner society
    • Mayo J.R., Aldrich J., and Müller N.L. Radiation exposure at chest CT: a statement of the Fleischner society. Radiology 228 1 (2003) 15-21
    • (2003) Radiology , vol.228 , Issue.1 , pp. 15-21
    • Mayo, J.R.1    Aldrich, J.2    Müller, N.L.3
  • 9
    • 0141841669 scopus 로고    scopus 로고
    • Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness
    • Fischbach F., Knollmann F., Griesshaber V., et al. Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness. Eur Radiol 13 10 (2003) 2378-2383
    • (2003) Eur Radiol , vol.13 , Issue.10 , pp. 2378-2383
    • Fischbach, F.1    Knollmann, F.2    Griesshaber, V.3
  • 10
    • 0037741079 scopus 로고    scopus 로고
    • The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devices
    • Muramatsu Y., Tsuda Y., Nakamura Y., et al. The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devices. J Comput Assist Tomogr 27 3 (2003) 364-374
    • (2003) J Comput Assist Tomogr , vol.27 , Issue.3 , pp. 364-374
    • Muramatsu, Y.1    Tsuda, Y.2    Nakamura, Y.3
  • 11
    • 36148973512 scopus 로고    scopus 로고
    • Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom
    • Ohno Y., Koyama H., Kono A., et al. Influence of detector collimation and beam pitch for identification and image quality of ground-glass attenuation and nodules on 16- and 64-detector row CT systems: experimental study using chest phantom. Eur J Radiol 64 3 (2007) 406-413
    • (2007) Eur J Radiol , vol.64 , Issue.3 , pp. 406-413
    • Ohno, Y.1    Koyama, H.2    Kono, A.3
  • 12
    • 34247468808 scopus 로고    scopus 로고
    • Pulmonary nodules: sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT data
    • Peloschek P., Sailer J., Weber M., et al. Pulmonary nodules: sensitivity of maximum intensity projection versus that of volume rendering of 3D multidetector CT data. Radiology 243 2 (2007) 561-569
    • (2007) Radiology , vol.243 , Issue.2 , pp. 561-569
    • Peloschek, P.1    Sailer, J.2    Weber, M.3
  • 13
    • 43249122162 scopus 로고    scopus 로고
    • Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT: experimental study using a chest CT phantom
    • Liu D., Awai K., Funama Y., Oda S., et al. Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT: experimental study using a chest CT phantom. Radiat Med 26 1 (2008) 21-27
    • (2008) Radiat Med , vol.26 , Issue.1 , pp. 21-27
    • Liu, D.1    Awai, K.2    Funama, Y.3    Oda, S.4
  • 14
    • 31444447203 scopus 로고    scopus 로고
    • Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices
    • Valencia R., Denecke T., Lehmkuhl L., Fischbach F., Felix R., and Knollmann F. Value of axial and coronal maximum intensity projection (MIP) images in the detection of pulmonary nodules by multislice spiral CT: comparison with axial 1-mm and 5-mm slices. Eur Radiol 16 2 (2006) 325-332
    • (2006) Eur Radiol , vol.16 , Issue.2 , pp. 325-332
    • Valencia, R.1    Denecke, T.2    Lehmkuhl, L.3    Fischbach, F.4    Felix, R.5    Knollmann, F.6
  • 15
    • 0036280811 scopus 로고    scopus 로고
    • Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT
    • Gruden J.F., Ouanounou S., Tigges S., Norris S.D., and Klausner T.S. Incremental benefit of maximum-intensity-projection images on observer detection of small pulmonary nodules revealed by multidetector CT. Am J Roentgenol 179 1 (2002) 149-157
    • (2002) Am J Roentgenol , vol.179 , Issue.1 , pp. 149-157
    • Gruden, J.F.1    Ouanounou, S.2    Tigges, S.3    Norris, S.D.4    Klausner, T.S.5
  • 16
    • 33947122052 scopus 로고    scopus 로고
    • Computer-assisted lung nodule volumetry from multi-detector row CT: influence of image reconstruction parameters
    • Honda O., Sumikawa H., Johkoh T., et al. Computer-assisted lung nodule volumetry from multi-detector row CT: influence of image reconstruction parameters. Eur J Radiol 62 1 (2007) 106-113
    • (2007) Eur J Radiol , vol.62 , Issue.1 , pp. 106-113
    • Honda, O.1    Sumikawa, H.2    Johkoh, T.3
  • 17
    • 0028892010 scopus 로고
    • CT reconstruction algorithm selection in the evaluation of solitary pulmonary nodules
    • Swensen S.J., Morin R.L., Aughenbaugh G.L., et al. CT reconstruction algorithm selection in the evaluation of solitary pulmonary nodules. J Comput Assist Tomogr 19 6 (1995) 932-935
    • (1995) J Comput Assist Tomogr , vol.19 , Issue.6 , pp. 932-935
    • Swensen, S.J.1    Morin, R.L.2    Aughenbaugh, G.L.3
  • 18
    • 0036831529 scopus 로고    scopus 로고
    • AAPM/RSNA physics tutorial for residents: topics in CT-radiation dose in CT
    • McNitt-Gray M.F. AAPM/RSNA physics tutorial for residents: topics in CT-radiation dose in CT. Radiographics 22 6 (2002) 1541-1553
    • (2002) Radiographics , vol.22 , Issue.6 , pp. 1541-1553
    • McNitt-Gray, M.F.1
  • 19
    • 0024459172 scopus 로고
    • Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
    • Svanholm H., Starklint H., Gundersen H.J., et al. Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic. APMIS 97 8 (1989) 689-698
    • (1989) APMIS , vol.97 , Issue.8 , pp. 689-698
    • Svanholm, H.1    Starklint, H.2    Gundersen, H.J.3
  • 20
    • 0038287738 scopus 로고    scopus 로고
    • Pulmonary nodule detection using chest CT images
    • Kim D.Y., Kim J.H., Noh S.M., et al. Pulmonary nodule detection using chest CT images. Acta Radiol 44 3 (2003) 252-257
    • (2003) Acta Radiol , vol.44 , Issue.3 , pp. 252-257
    • Kim, D.Y.1    Kim, J.H.2    Noh, S.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.