메뉴 건너뛰기




Volumn 26, Issue 1, 2008, Pages 21-27

Identification and characterization of focal ground-glass opacity in the lungs by high-resolution CT using thin-section multidetector helical CT: Experimental study using a chest CT phantom

Author keywords

Ground glass opacity (GGO); High resolution CT; Lung cancer; Phantom

Indexed keywords

ARTICLE; ARTIFACT; DIAGNOSTIC IMAGING; EXPERIMENTAL STUDY; HIGH RESOLUTION COMPUTER TOMOGRAPHY; IMAGE ANALYSIS; IMAGE QUALITY; LUNG CANCER; MULTIDETECTOR COMPUTED TOMOGRAPHY; PHANTOM; RADIATION DOSE; SPIRAL COMPUTER ASSISTED TOMOGRAPHY; THORAX RADIOGRAPHY; ANALYSIS OF VARIANCE; HUMAN; LUNG DISEASE; METHODOLOGY; OBSERVER VARIATION; RADIOGRAPHY; ROC CURVE;

EID: 43249122162     PISSN: 02882043     EISSN: 18625274     Source Type: Journal    
DOI: 10.1007/s11604-007-0190-y     Document Type: Article
Times cited : (10)

References (31)
  • 1
    • 0029894886 scopus 로고    scopus 로고
    • Glossary of terms for CT of the lungs: Recommendations of the Nomenclature Committee of the Fleischner Society
    • Austin JH, Muller NL, Friedman PJ, Hansell DM, Naidich DP, Remy-Jardin, et al. Glossary of terms for CT of the lungs: recommendations of the Nomenclature Committee of the Fleischner Society. Radiology 1996;200:327-331.
    • (1996) Radiology , vol.200 , pp. 327-331
    • Austin, J.H.1    Muller, N.L.2    Friedman, P.J.3    Hansell, D.M.4    Naidich, D.P.5    Remy-Jardin6
  • 2
    • 0034960784 scopus 로고    scopus 로고
    • Prognostic value of ground-glass opacity found in small lung adenocarcinoma on high-resolution CT scanning
    • Kodama K, Higashiyama M, Yokouchi H, Takami K, Kuriyama K, Mano M, et al. Prognostic value of ground-glass opacity found in small lung adenocarcinoma on high-resolution CT scanning. Lung Cancer 2001;33:17-25.
    • (2001) Lung Cancer , vol.33 , pp. 17-25
    • Kodama, K.1    Higashiyama, M.2    Yokouchi, H.3    Takami, K.4    Kuriyama, K.5    Mano, M.6
  • 3
    • 0032793947 scopus 로고    scopus 로고
    • Ground-glass opacity on thin-section CT: Value in differentiating subtypes of adenocarcinoma of the lung
    • Kuriyama K, Seto M, Kasugai T, Higashiyama M, Kido S, Sawai Y, et al. Ground-glass opacity on thin-section CT: value in differentiating subtypes of adenocarcinoma of the lung. AJR Am J Roentgenol 1999;173:465-469.
    • (1999) AJR Am J Roentgenol , vol.173 , pp. 465-469
    • Kuriyama, K.1    Seto, M.2    Kasugai, T.3    Higashiyama, M.4    Kido, S.5    Sawai, Y.6
  • 7
    • 0032565365 scopus 로고    scopus 로고
    • Mass screening for lung cancer with mobile spiral computed tomography scanner
    • Sone S, Takashima S, Li F, Yang Z, Honda T, Maruyama Y, et al. Mass screening for lung cancer with mobile spiral computed tomography scanner. Lancet 1998;351:1242-1245.
    • (1998) Lancet , vol.351 , pp. 1242-1245
    • Sone, S.1    Takashima, S.2    Li, F.3    Yang, Z.4    Honda, T.5    Maruyama, Y.6
  • 8
    • 0036784139 scopus 로고    scopus 로고
    • CT screening for lung cancer
    • Swensen SJ. CT screening for lung cancer. AJR Am J Roentgenol 2002;179:833-836.
    • (2002) AJR Am J Roentgenol , vol.179 , pp. 833-836
    • Swensen, S.J.1
  • 9
    • 0034004916 scopus 로고    scopus 로고
    • Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time
    • Aoki T, Nakata H, Watanabe H, Nakamura K, Kasai T, Hashimoto H, et al. Evolution of peripheral lung adenocarcinomas: CT findings correlated with histology and tumor doubling time. AJR Am J Roentgenol 2000;174:763-768.
    • (2000) AJR Am J Roentgenol , vol.174 , pp. 763-768
    • Aoki, T.1    Nakata, H.2    Watanabe, H.3    Nakamura, K.4    Kasai, T.5    Hashimoto, H.6
  • 11
    • 0034867875 scopus 로고    scopus 로고
    • Peripheral lung adenocarcinoma: Correlation of thin-section CT findings with histologic prognostic factors and survival
    • Aoki T, Tomoda Y, Watanabe H, Nakata H, Kasai T, Hashimoto H, et al. Peripheral lung adenocarcinoma: correlation of thin-section CT findings with histologic prognostic factors and survival. Radiology 2001;220:803-809.
    • (2001) Radiology , vol.220 , pp. 803-809
    • Aoki, T.1    Tomoda, Y.2    Watanabe, H.3    Nakata, H.4    Kasai, T.5    Hashimoto, H.6
  • 12
    • 0034032027 scopus 로고    scopus 로고
    • Prognostic significance of the size of central fibrosis in peripheral adenocarcinoma of the lung
    • Suzuki K, Yokose T, Yoshida J, Nishimura M, Takahashi K, Nagai K, et al. Prognostic significance of the size of central fibrosis in peripheral adenocarcinoma of the lung. Ann Thorac Surg 2000;69:893-897.
    • (2000) Ann Thorac Surg , vol.69 , pp. 893-897
    • Suzuki, K.1    Yokose, T.2    Yoshida, J.3    Nishimura, M.4    Takahashi, K.5    Nagai, K.6
  • 13
    • 0025799886 scopus 로고
    • Low-dose high-resolution CT of lung parenchyma
    • Zwirewich CV, Mayo JR, Muller NL. Low-dose high-resolution CT of lung parenchyma. Radiology 1991;180:413-417.
    • (1991) Radiology , vol.180 , pp. 413-417
    • Zwirewich, C.V.1    Mayo, J.R.2    Muller, N.L.3
  • 14
    • 0037741079 scopus 로고    scopus 로고
    • The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devices
    • Muramatsu Y, Tsuda Y, Nakamura Y, Kubo M, Takayama T, Hanai K. The development and use of a chest phantom for optimizing scanning techniques on a variety of low-dose helical computed tomography devices. J Comput Assist Tomogr 2003;27:364-374.
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 364-374
    • Muramatsu, Y.1    Tsuda, Y.2    Nakamura, Y.3    Kubo, M.4    Takayama, T.5    Hanai, K.6
  • 15
    • 0035161046 scopus 로고    scopus 로고
    • A consensus statement of the Society of Thoracic Radiology: Screening for lung cancer with helical computed tomography
    • Aberle DR, Gamsu G, Henschke CI, Naidich DP, Swensen SJ. A consensus statement of the Society of Thoracic Radiology: screening for lung cancer with helical computed tomography. J Thorac Imaging 2001;16:65-68.
    • (2001) J Thorac Imaging , vol.16 , pp. 65-68
    • Aberle, D.R.1    Gamsu, G.2    Henschke, C.I.3    Naidich, D.P.4    Swensen, S.J.5
  • 16
    • 0024459172 scopus 로고
    • Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic
    • Svanholm H, Starklint H, Gundersen HJ, Fabricius J, Barlebo H, Olsen S. Reproducibility of histomorphologic diagnoses with special reference to the kappa statistic. APMIS 1989;97:689-698.
    • (1989) APMIS , vol.97 , pp. 689-698
    • Svanholm, H.1    Starklint, H.2    Gundersen, H.J.3    Fabricius, J.4    Barlebo, H.5    Olsen, S.6
  • 17
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 18
    • 0141518516 scopus 로고    scopus 로고
    • Receiver operating characteristic curves and their use in radiology
    • Obuchowski NA. Receiver operating characteristic curves and their use in radiology. Radiology 2003;229:3-8.
    • (2003) Radiology , vol.229 , pp. 3-8
    • Obuchowski, N.A.1
  • 19
    • 0032525017 scopus 로고    scopus 로고
    • Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data
    • Metz CE, Herman BA, Shen JH. Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. Stat Med 1998;17:1033-1053.
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 22
    • 0036308385 scopus 로고    scopus 로고
    • Lung cancer screening using low-dose spiral CT: Results of baseline and 1-year follow-up studies
    • Nawa T, Nakagawa T, Kusano S, Kawasaki Y, Sugawara Y, Nakata H. Lung cancer screening using low-dose spiral CT: results of baseline and 1-year follow-up studies. Chest 2002;122:15-20.
    • (2002) Chest , vol.122 , pp. 15-20
    • Nawa, T.1    Nakagawa, T.2    Kusano, S.3    Kawasaki, Y.4    Sugawara, Y.5    Nakata, H.6
  • 23
    • 0036892529 scopus 로고    scopus 로고
    • Lung cancers missed at low-dose helical CT screening in a general population: Comparison of clinical, histopathologic, and imaging findings
    • Li F, Sone S, Abe H, MacMahon H, Armato SG 3rd, Doi K. Lung cancers missed at low-dose helical CT screening in a general population: comparison of clinical, histopathologic, and imaging findings. Radiology 2002;225:673-683.
    • (2002) Radiology , vol.225 , pp. 673-683
    • Li, F.1    Sone, S.2    Abe, H.3    MacMahon, H.4    Armato III, S.G.5    Doi, K.6
  • 24
    • 27144445835 scopus 로고    scopus 로고
    • Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: Initial experience
    • Kim KG, Goo JM, Kim JH, Lee HJ, Min BG, Bae KT, et al. Computer-aided diagnosis of localized ground-glass opacity in the lung at CT: initial experience. Radiology 2005;237:657-661.
    • (2005) Radiology , vol.237 , pp. 657-661
    • Kim, K.G.1    Goo, J.M.2    Kim, J.H.3    Lee, H.J.4    Min, B.G.5    Bae, K.T.6
  • 25
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys 1999;26:5-18.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 26
    • 34147215960 scopus 로고    scopus 로고
    • CT screening for lung cancer: Diagnoses resulting from the New York Early Lung Cancer Action Project
    • New York Early Lung Cancer Action Project Investigators.
    • New York Early Lung Cancer Action Project Investigators. CT screening for lung cancer: diagnoses resulting from the New York Early Lung Cancer Action Project. Radiology 2007;243:239-29.
    • (2007) Radiology , vol.243 , pp. 239-29
  • 30
    • 2142695134 scopus 로고    scopus 로고
    • Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer
    • Brenner DJ. Radiation risks potentially associated with low-dose CT screening of adult smokers for lung cancer. Radiology 2004;231:440-445.
    • (2004) Radiology , vol.231 , pp. 440-445
    • Brenner, D.J.1
  • 31
    • 4143081306 scopus 로고    scopus 로고
    • Estimated radiation risks potentially associated with full-body CT screening
    • Brenner DJ, Elliston CD. Estimated radiation risks potentially associated with full-body CT screening. Radiology 2004;232:735-738.
    • (2004) Radiology , vol.232 , pp. 735-738
    • Brenner, D.J.1    Elliston, C.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.