Volumn 63, Issue 6, 2010, Pages 1493-1501

Triple repetition time saturation transfer (TRiST) 31P spectroscopy for measuring human creatine kinase reaction kinetics

Author keywords

3 tesla; Creatine kinase; High energy phosphate; Human heart; Metabolism; Reaction rate; Saturation pulses; Saturation transfer

Indexed keywords

ENZYMES; HEART; METABOLISM; METABOLITES; MUSCLE; RATE CONSTANTS; REACTION RATES;

EID: 77952685206     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.22347     Document Type: Article
Times cited : (54)

References (33)
  • 1
    • 33846851242 scopus 로고
    • Study of moderately rapid chemical exchange reactions by means of nuclear magnetic double resonance
    • Forsen S, Hoffman RA. Study of moderately rapid chemical exchange reactions by means of nuclear magnetic double resonance. J Chem Phys 1963;39:2892.
    • (1963) J Chem Phys , vol.39 , pp. 2892
    • Forsen, S.1    Hoffman, R.A.2
  • 2
    • 0001692543 scopus 로고
    • Mapping creatine-kinase reaction-rates in human brain and heart with 4-tesla saturation transfer P-31 NMR
    • Bottomley PA, Hardy CJ. Mapping creatine-kinase reaction-rates in human brain and heart with 4-tesla saturation transfer P-31 NMR. J Magn Reson 1992;99:443-448.
    • (1992) J Magn Reson , vol.99 , pp. 443-448
    • Bottomley, P.A.1    Hardy, C.J.2
  • 3
    • 33846088914 scopus 로고    scopus 로고
    • 31P magnetization transfer approach for noninvasively determining multiple kinetic parameters and metabolic fluxes of ATP metabolism in the human brain
    • DOI 10.1002/mrm.21107
    • Du F, Zhu XH, Qiao H, Zhang X, Chen W. Efficient in vivo 31P magnetization transfer approach for noninvasively determining multiple kinetic parameters and metabolic fluxes of ATP metabolism in the human brain. Magn Reson Med 2007;57:103-114. (Pubitemid 46067941)
    • (2007) Magnetic Resonance in Medicine , vol.57 , Issue.1 , pp. 103-114
    • Du, F.1    Zhu, X.-H.2    Qiao, H.3    Zhang, X.4    Chen, W.5
  • 4
    • 0036236261 scopus 로고    scopus 로고
    • Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo
    • Bottomley PA, Ouwerkerk R, Lee RF, Weiss RG. Four-angle saturation transfer (FAST) method for measuring creatine kinase reaction rates in vivo. Magn Reson Med 2002;47:850-863.
    • (2002) Magn Reson Med , vol.47 , pp. 850-863
    • Bottomley, P.A.1    Ouwerkerk, R.2    Lee, R.F.3    Weiss, R.G.4
  • 5
    • 0033864226 scopus 로고    scopus 로고
    • The relationship between creatine kinase kinetics and exercise intensity in human forearm is unchanged by age
    • Horska A, Fishbein KW, Fleg JL, Spencer RG. The relationship between creatine kinase kinetics and exercise intensity in human forearm is unchanged by age. Am J Physiol 2000;279:E333-339.
    • (2000) Am J Physiol , vol.279
    • Horska, A.1    Fishbein, K.W.2    Fleg, J.L.3    Spencer, R.G.4
  • 7
    • 0030611067 scopus 로고    scopus 로고
    • 31P NMR saturation transfer study of the creatine kinase reaction in human skeletal muscle at rest and during exercise
    • Goudemant JF, Francaux M, Mottet I, Demeure R, Sibomana M, Sturbois X. 31P NMR saturation transfer study of the creatine kinase reaction in human skeletal muscle at rest and during exercise. Magn Reson Med 1997;37:744-753. (Pubitemid 27187815)
    • (1997) Magnetic Resonance in Medicine , vol.37 , Issue.5 , pp. 744-753
    • Goudemant, J.-F.1    Francaux, M.2    Mottet, I.3    Demeure, R.4    Sibomana, M.5    Sturbois, X.6
  • 8
    • 0034886764 scopus 로고    scopus 로고
    • Creatine loading and resting skeletal muscle phosphocreatine flux: A saturation-transfer NMR study
    • Wiedermann D, Schneider J, Fromme A, Thorwesten L, Moller HE. Creatine loading and resting skeletal muscle phosphocreatine flux: a saturation-transfer NMR study. MAGMA 2001;13:118-126.
    • (2001) MAGMA , vol.13 , pp. 118-126
    • Wiedermann, D.1    Schneider, J.2    Fromme, A.3    Thorwesten, L.4    Moller, H.E.5
  • 10
    • 65549089030 scopus 로고    scopus 로고
    • Reduced myocardial creatine kinase flux in human myocardial infarction: An in vivo phosphorus magnetic resonance spectroscopy study
    • Bottomley PA, Wu KC, Gerstenblith G, Schulman SP, Steinberg A, Weiss RG. Reduced myocardial creatine kinase flux in human myocardial infarction: an in vivo phosphorus magnetic resonance spectroscopy study. Circulation 2009;119:1918-1924.
    • (2009) Circulation , vol.119 , pp. 1918-1924
    • Bottomley, P.A.1    Wu, K.C.2    Gerstenblith, G.3    Schulman, S.P.4    Steinberg, A.5    Weiss, R.G.6
  • 11
    • 33748668461 scopus 로고    scopus 로고
    • Altered creatine kinase adenosine triphosphate kinetics in failing hypertrophied human myocardium
    • DOI 10.1161/CIRCULATIONAHA.106.613646, PII 0000301720060912000007
    • Smith CS, Bottomley PA, Schulman SP, Gerstenblith G, Weiss RG. Altered creatine kinase adenosine triphosphate kinetics in failing hypertrophied human myocardium. Circulation 2006;114:1151-1158. (Pubitemid 44386479)
    • (2006) Circulation , vol.114 , Issue.11 , pp. 1151-1158
    • Smith, C.S.1    Bottomley, P.A.2    Schulman, S.P.3    Gerstenblith, G.4    Weiss, R.G.5
  • 12
    • 76349093379 scopus 로고    scopus 로고
    • (31)P magnetic resonance spectroscopy to measure in vivo cardiac energetics in normal myocardium and hypertrophic cardiomyopathy: Experiences at 3 T
    • doi:10.1016/j.ejrad.2008. 10.018
    • Shivu GN, Abozguia K, Phan TT, Ahmed I, Henning A, Frenneaux M. (31)P magnetic resonance spectroscopy to measure in vivo cardiac energetics in normal myocardium and hypertrophic cardiomyopathy: experiences at 3 T. Eur J Radiol 2008 [doi:10.1016/j.ejrad.2008. 10.018].
    • (2008) Eur J Radiol
    • Shivu, G.N.1    Abozguia, K.2    Phan, T.T.3    Ahmed, I.4    Henning, A.5    Frenneaux, M.6
  • 15
    • 0031254249 scopus 로고    scopus 로고
    • Off-Resonance Irradiation Effect in Steady-State NMR Saturation Transfer
    • Baguet E, Roby C. Off-resonance irradiation effect in steady-state NMR saturation transfer. J Magn Reson 1997;128:149-160. (Pubitemid 127452798)
    • (1997) Journal of Magnetic Resonance , vol.128 , Issue.2 , pp. 149-160
    • Baguet, E.1    Roby, C.2
  • 16
    • 0019463054 scopus 로고
    • The activity of creatine kinase in frog skeletal muscle studied by saturation-transfer nuclear magnetic resonance
    • Gadian DG, Radda GK, Brown TR, Chance EM, Dawson MJ, Wilkie DR. The activity of creatine kinase in frog skeletal muscle studied by saturation-transfer nuclear magnetic resonance. Biochem J 1981;194: 215-228.
    • (1981) Biochem J , vol.194 , pp. 215-228
    • Gadian, D.G.1    Radda, G.K.2    Brown, T.R.3    Chance, E.M.4    Dawson, M.J.5    Wilkie, D.R.6
  • 17
    • 0030744497 scopus 로고    scopus 로고
    • Correctly accounting for radiofrequency spill-over in saturation transfer experiments: Application to measurement of the creatine kinase reaction rate in human forearm muscle
    • Horska A, Spencer GS. Correctly accounting for radiofrequency spill-over in saturation transfer experiments: application to measurement of the creatine kinase reaction rate in human forearm muscle. MAGMA 1997;5:159-163.
    • (1997) MAGMA , vol.5 , pp. 159-163
    • Horska, A.1    Spencer, G.S.2
  • 18
    • 43949147518 scopus 로고
    • The dual-angle method for fast, sensitive T-1 measurement in-vivo with low-angle adiabatic pulses
    • Bottomley PA, Ouwerkerk R. The dual-angle method for fast, sensitive T-1 measurement in-vivo with low-angle adiabatic pulses. J Magn Reson B 1994;104:159-167.
    • (1994) J Magn Reson B , vol.104 , pp. 159-167
    • Bottomley, P.A.1    Ouwerkerk, R.2
  • 19
    • 44949273876 scopus 로고
    • Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets
    • Garwood M, Ke Y. Symmetric pulses to induce arbitrary flip angles with compensation for RF inhomogeneity and resonance offsets. J Magn Reson Med 1991;94:511-525.
    • (1991) J Magn Reson Med , vol.94 , pp. 511-525
    • Garwood, M.1    Ke, Y.2
  • 20
    • 0000383044 scopus 로고
    • BIRP: An improved implementation of low-angle adiabatic (BIR-4) excitation pulses
    • Bottomley PA, Ouwerkerk R. BIRP: an improved implementation of low-angle adiabatic (BIR-4) excitation pulses. J Magn Reson A 1993; 103:242-244.
    • (1993) J Magn Reson A , vol.103 , pp. 242-244
    • Bottomley, P.A.1    Ouwerkerk, R.2
  • 22
    • 0000224420 scopus 로고
    • Simple pulse sequence for selective excitation in Fourier-transform NMR
    • Bodenhausen G, Freeman R, Morris GA. Simple pulse sequence for selective excitation in Fourier-transform NMR. J Magn Reson 1976; 23:171-175.
    • (1976) J Magn Reson , vol.23 , pp. 171-175
    • Bodenhausen, G.1    Freeman, R.2    Morris, G.A.3
  • 23
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • Fischer SE, Wickline SA, Lorenz CH. Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions. Magn Reson Med 1999;42:361-370.
    • (1999) Magn Reson Med , vol.42 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3
  • 27
    • 40949105909 scopus 로고    scopus 로고
    • Correcting reaction rates measured by saturation-transfer magnetic resonance spectroscopy
    • Gabr RE, Weiss RG, Bottomley PA. Correcting reaction rates measured by saturation-transfer magnetic resonance spectroscopy. J Magn Reson 2008;191:248-258.
    • (2008) J Magn Reson , vol.191 , pp. 248-258
    • Gabr, R.E.1    Weiss, R.G.2    Bottomley, P.A.3
  • 28
    • 0029928495 scopus 로고    scopus 로고
    • Heart rate variability: Standards of measurement, physiological interpretation and clinical use
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology
    • Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. Heart rate variability: standards of measurement, physiological interpretation and clinical use. Circulation 1996;93:1043-1065.
    • (1996) Circulation , vol.93 , pp. 1043-1065
  • 33
    • 0022499150 scopus 로고
    • Measurement of an individual rate constant in the presence of multiple exchanges: Application to myocardial creatine kinase reaction
    • Ugurbil K, Petein M, Maidan R, Michurski S, From AH. Measurement of an individual rate constant in the presence of multiple exchanges: application to myocardial creatine kinase reaction. Biochemistry 1986;25:100-107. (Pubitemid 16053085)
    • (1986) Biochemistry , vol.25 , Issue.1 , pp. 100-107
    • Ugurbil, K.1    Petein, M.2    Maidan, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.