메뉴 건너뛰기




Volumn 21, Issue 8, 2008, Pages 793-798

A comparison of cardiac 31P MRS at 1.5 and 3 T

Author keywords

Cardiac energetics; Field strength; MRS; Phosphorus

Indexed keywords

CARDIAC ENERGETICS; FIELD STRENGTH; MRS; PHOSPHORUS;

EID: 53849120978     PISSN: 09523480     EISSN: 10991492     Source Type: Journal    
DOI: 10.1002/nbm.1255     Document Type: Article
Times cited : (37)

References (21)
  • 1
    • 0031657280 scopus 로고    scopus 로고
    • Clinical cardiac magnetic resonance spectroscopy: Present state and future directions
    • Neubauer S, Horn M, Hahn D, Kochsiek KT. Clinical cardiac magnetic resonance spectroscopy: present state and future directions. Mol. Cell. Biochem. 1998; 184(1-2): 439-443.
    • (1998) Mol. Cell. Biochem , vol.184 , Issue.1-2 , pp. 439-443
    • Neubauer, S.1    Horn, M.2    Hahn, D.3    Kochsiek, K.T.4
  • 5
    • 0026000171 scopus 로고
    • Detection of low phosphocreatine to ATP ratio in failing hypertrophied human myocardium by P-31 magnetic-resonance spectroscopy
    • Conway MA, Allis J, Ouwerkerk R, Niioka T, Rajagopalan B, Radda GK. Detection of low phosphocreatine to ATP ratio in failing hypertrophied human myocardium by P-31 magnetic-resonance spectroscopy. Lancet 1991; 338(8773): 973-976.
    • (1991) Lancet , vol.338 , Issue.8773 , pp. 973-976
    • Conway, M.A.1    Allis, J.2    Ouwerkerk, R.3    Niioka, T.4    Rajagopalan, B.5    Radda, G.K.6
  • 6
    • 0032485850 scopus 로고    scopus 로고
    • Mitral regurgitation: Impaired systolic function, eccentric hypertrophy, and increased severity are linked to lower phosphocreatine/ATP ratios in humans
    • Conway MA, Bottomley PA, Ouwerkerk R, Radda GK, Rajagopalan B. Mitral regurgitation: impaired systolic function, eccentric hypertrophy, and increased severity are linked to lower phosphocreatine/ATP ratios in humans. Circulation 1998; 97(17): 1716-1723.
    • (1998) Circulation , vol.97 , Issue.17 , pp. 1716-1723
    • Conway, M.A.1    Bottomley, P.A.2    Ouwerkerk, R.3    Radda, G.K.4    Rajagopalan, B.5
  • 9
    • 0001335546 scopus 로고
    • Correcting human heart P-31 NMR-spectra for partial saturation - evidence that saturation factors for PCr ATP are homogeneous in normal and disease states
    • Bottomley PA, Hardy CJ, Weiss RG. Correcting human heart P-31 NMR-spectra for partial saturation - evidence that saturation factors for PCr ATP are homogeneous in normal and disease states. Journal Of Magnetic Resonance 1991; 95(2): 341-355.
    • (1991) Journal Of Magnetic Resonance , vol.95 , Issue.2 , pp. 341-355
    • Bottomley, P.A.1    Hardy, C.J.2    Weiss, R.G.3
  • 11
    • 0026612010 scopus 로고
    • P-31 NMR-spectroscopy of the human heart at 4-T: Detection of substantially uncontaminated cardiac spectra and differentiation of subepicardium and subendocardium
    • Menon RS, Hendrich K, Hu XP, Ugurbil K. P-31 NMR-spectroscopy of the human heart at 4-T: detection of substantially uncontaminated cardiac spectra and differentiation of subepicardium and subendocardium. Magnetic Resonance In Medicine 1992; 26(2): 368-376.
    • (1992) Magnetic Resonance In Medicine , vol.26 , Issue.2 , pp. 368-376
    • Menon, R.S.1    Hendrich, K.2    Hu, X.P.3    Ugurbil, K.4
  • 12
    • 43949147518 scopus 로고
    • The dual-angle method for fast, Sensitive T-1 measurement in-vivo with low-angle adiabatic pulses
    • Bottomley PA, Ouwerkerk R. The dual-angle method for fast, Sensitive T-1 measurement in-vivo with low-angle adiabatic pulses. Journal Of Magnetic Resonance Series B 1994; 104(2): 159-167.
    • (1994) Journal Of Magnetic Resonance Series B , vol.104 , Issue.2 , pp. 159-167
    • Bottomley, P.A.1    Ouwerkerk, R.2
  • 14
    • 0000383044 scopus 로고
    • BIRP, an improved implementation of low-angle adiabatic (BIR-4) excitation pulses
    • Bottomley PA, Ouwerkerk R. BIRP, an improved implementation of low-angle adiabatic (BIR-4) excitation pulses. Journal Of Magnetic Resonance Series A 1993; 103(2): 242-244.
    • (1993) Journal Of Magnetic Resonance Series A , vol.103 , Issue.2 , pp. 242-244
    • Bottomley, P.A.1    Ouwerkerk, R.2
  • 15
    • 0035033455 scopus 로고    scopus 로고
    • Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals
    • Naressi A, Couturier C, Castang I, de Beer R, Uraveron-Demilly D. Java-based graphical user interface for MRUI, a software package for quantitation of in vivo/medical magnetic resonance spectroscopy signals. Computers In Biology And Medicine 2001; 31(4): 269-286.
    • (2001) Computers In Biology And Medicine , vol.31 , Issue.4 , pp. 269-286
    • Naressi, A.1    Couturier, C.2    Castang, I.3    de Beer, R.4    Uraveron-Demilly, D.5
  • 17
    • 0028365711 scopus 로고
    • Optimum flip-angles for exciting NMR with uncertain T-1 values
    • Bottomley PA, Ouwerkerk R. Optimum flip-angles for exciting NMR with uncertain T-1 values. Magnetic Resonance In Medicine 1994; 32(1): 137-141.
    • (1994) Magnetic Resonance In Medicine , vol.32 , Issue.1 , pp. 137-141
    • Bottomley, P.A.1    Ouwerkerk, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.