메뉴 건너뛰기




Volumn 43, Issue 4, 2010, Pages 694-700

Detecting femur-insert collisions to improve precision of fluoroscopic knee arthroplasty analysis

Author keywords

Collision detection; Fluoroscopic analysis; Pose estimation

Indexed keywords

ACCURACY AND PRECISION; CAD MODELS; COLLISION DETECTION; FEMORAL COMPONENT; FLUOROSCOPIC ANALYSIS; IN-VIVO; KNEE ARTHROPLASTY; ORIENTATION PARAMETER; OUT-OF-PLANE; OUT-OF-PLANE DIRECTION; PHANTOM STUDIES; POSE ESTIMATION; RELATIVE POSE; REVERSE ENGINEERED MODELS;

EID: 77952496334     PISSN: 00219290     EISSN: 18732380     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.10.023     Document Type: Article
Times cited : (26)

References (17)
  • 1
    • 0030175447 scopus 로고    scopus 로고
    • Accurate measurements of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    • Banks S., Hodge W. Accurate measurements of three-dimensional knee replacement kinematics using single-plane fluoroscopy. IEEE Transactions on Biomedical Engineering 1996, 43(6):638-649.
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.6 , pp. 638-649
    • Banks, S.1    Hodge, W.2
  • 2
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical assessment
    • Bland J., Altman D. Statistical methods for assessing agreement between two methods of clinical assessment. Lancet 1986, 1(8476):307-310.
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.1    Altman, D.2
  • 4
    • 57049181892 scopus 로고    scopus 로고
    • A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images.
    • Medical & Biological Engineering & Computing.
    • Hirokawa, S., Hossain, M.A., Kihara, Y., Ariyoshi, S., 2008. A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images. Medical & Biological Engineering & Computing.
    • (2008)
    • Hirokawa, S.1    Hossain, M.A.2    Kihara, Y.3    Ariyoshi, S.4
  • 5
    • 0030394237 scopus 로고    scopus 로고
    • Pose estimation of artificial knee implants in fluoroscopy images using a template matching technique
    • Proceedings of the Third IEEE Workshop on Applications of Computer Vision, 1996. WACV'96'
    • Hoff, W., & Komistek, R., Dennis, D., Walker, S., Northcut, E., Spargo, K., 1996. Pose estimation of artificial knee implants in fluoroscopy images using a template matching technique. In: Proceedings of the Third IEEE Workshop on Applications of Computer Vision, 1996. WACV'96', pp. 181-186.
    • (1996) , pp. 181-186
    • Hoff, W.1    Komistek, R.2    Dennis, D.3    Walker, S.4    Northcut, E.5    Spargo, K.6
  • 6
    • 0032189583 scopus 로고    scopus 로고
    • Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy
    • Hoff W., Komistek R., Dennis D., Gabriel S., Walker S. Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy. Clinical Biochemistry (Bristol, Avon) 1998, 13(7):455-472.
    • (1998) Clinical Biochemistry (Bristol, Avon) , vol.13 , Issue.7 , pp. 455-472
    • Hoff, W.1    Komistek, R.2    Dennis, D.3    Gabriel, S.4    Walker, S.5
  • 8
    • 0037692766 scopus 로고    scopus 로고
    • A new model-based RSA method validated using CAD models and models from reversed engineering
    • Kaptein B., Valstar E., Stoel B., Rozing P., Reiber J. A new model-based RSA method validated using CAD models and models from reversed engineering. Journal of Biomechanics 2003, 36(6):873-882.
    • (2003) Journal of Biomechanics , vol.36 , Issue.6 , pp. 873-882
    • Kaptein, B.1    Valstar, E.2    Stoel, B.3    Rozing, P.4    Reiber, J.5
  • 9
    • 0038066801 scopus 로고    scopus 로고
    • In vivo fluoroscopic analysis of the normal human knee: Knee kinematics and total knee replacement design.
    • Clinical orthopaedics and related research 410
    • Komistek, R., Dennis, D., Mahfouz, M., 2003. In vivo fluoroscopic analysis of the normal human knee: Knee kinematics and total knee replacement design. Clinical orthopaedics and related research 410, 69-81.
    • (2003) , pp. 69-81
    • Komistek, R.1    Dennis, D.2    Mahfouz, M.3
  • 11
    • 42749092342 scopus 로고    scopus 로고
    • Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion
    • Li G., Van de Velde S., Bingham J. Validation of a non-invasive fluoroscopic imaging technique for the measurement of dynamic knee joint motion. Journal of Biomechanics 2008, 41(7):1616-1622.
    • (2008) Journal of Biomechanics , vol.41 , Issue.7 , pp. 1616-1622
    • Li, G.1    Van de Velde, S.2    Bingham, J.3
  • 12
    • 0344012667 scopus 로고    scopus 로고
    • A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images
    • Mahfouz M., Hoff W., Komistek R., Dennis D. A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Transactions on Medical Imaging 2003, 22(12):1561-1574.
    • (2003) IEEE Transactions on Medical Imaging , vol.22 , Issue.12 , pp. 1561-1574
    • Mahfouz, M.1    Hoff, W.2    Komistek, R.3    Dennis, D.4
  • 13
    • 84859775332 scopus 로고    scopus 로고
    • OpCode, the collision detection library from the Open Dynamics Engine
    • OpCode, the collision detection library from the Open Dynamics Engine, http://www.ode.org.
  • 15
    • 0037396234 scopus 로고    scopus 로고
    • In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency
    • Tashman S., Anderst W. In-vivo measurement of dynamic joint motion using high speed biplane radiography and CT: application to canine ACL deficiency. Journal of Biomechanical Engineering 2003, 125:238.
    • (2003) Journal of Biomechanical Engineering , vol.125 , pp. 238
    • Tashman, S.1    Anderst, W.2
  • 16
    • 0035354206 scopus 로고    scopus 로고
    • In vivo measurement of 3-D skeletal kinematics from sequences ofbiplane radiographs: application to knee kinematics
    • You B., Siy P., Anderst W., Tashman S. In vivo measurement of 3-D skeletal kinematics from sequences ofbiplane radiographs: application to knee kinematics. IEEE Transactions on Medical Imaging 2001, 20(6):514-525.
    • (2001) IEEE Transactions on Medical Imaging , vol.20 , Issue.6 , pp. 514-525
    • You, B.1    Siy, P.2    Anderst, W.3    Tashman, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.