메뉴 건너뛰기




Volumn 86, Issue 10, 2005, Pages 2066-2070

A self-contained, mechanomyography-driven externally powered prosthesis

Author keywords

Amputees; Arm; Classification; Linear regression; Prostheses and implants; Prosthesis design; Rehabilitation

Indexed keywords

ACCURACY; ADULT; AGED; ARM AMPUTATION; ARTICLE; CASE REPORT; COMPUTER PROGRAM; ELECTROMYOGRAPHY; ELECTRONICS; ENVIRONMENT; HAND PROSTHESIS; HUMAN; MECHANOMYOGRAPHY; MYOGRAPHY; NOISE; NOISE REDUCTION; QUANTITATIVE ANALYSIS; RECORDING; SENSOR; SIGNAL DETECTION; VOLUNTARY MOVEMENT;

EID: 26444583925     PISSN: 00039993     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.apmr.2005.03.034     Document Type: Article
Times cited : (109)

References (9)
  • 1
    • 0032005810 scopus 로고    scopus 로고
    • MMG measurement: A high sensitivity microphone-based sensor for clinical use
    • A. Courteville, T. Gharbi, J.Y. Cornu MMG measurement a high sensitivity microphone-based sensor for clinical use IEEE Trans Biomed Eng 45 1998 145 150
    • (1998) IEEE Trans Biomed Eng , vol.45 , pp. 145-150
    • Courteville, A.1    Gharbi, T.2    Cornu, J.Y.3
  • 2
    • 0027155822 scopus 로고
    • Muscle sound: Bases for the introduction of a mechanomyographic signal in muscle studies
    • C. Orizio Muscle sound bases for the introduction of a mechanomyographic signal in muscle studies Crit Rev Biomed Eng 21 1993 201 243
    • (1993) Crit Rev Biomed Eng , vol.21 , pp. 201-243
    • Orizio, C.1
  • 3
    • 3042518876 scopus 로고    scopus 로고
    • Mechanomyography versus electromyography, in monitoring the muscular fatigue
    • M.T. Tarata Mechanomyography versus electromyography, in monitoring the muscular fatigue Biomed Eng Online 2 2003 3
    • (2003) Biomed Eng Online , vol.2 , pp. 3
    • Tarata, M.T.1
  • 4
    • 0032862320 scopus 로고    scopus 로고
    • Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration
    • M. Ouamer, M. Boiteux, M. Petitjean, L. Travens, A. Sales Acoustic myography during voluntary isometric contraction reveals non-propagative lateral vibration J Biomech 32 1999 1279 1285
    • (1999) J Biomech , vol.32 , pp. 1279-1285
    • Ouamer, M.1    Boiteux, M.2    Petitjean, M.3    Travens, L.4    Sales, A.5
  • 5
    • 0022587670 scopus 로고
    • Acoustic myography as a control signal for an externally powered prosthesis
    • D.T. Barry, J.A. Leonard, A.J. Gitter, R.D. Ball Acoustic myography as a control signal for an externally powered prosthesis Arch Phys Med Rehabil 67 1986 267 269
    • (1986) Arch Phys Med Rehabil , vol.67 , pp. 267-269
    • Barry, D.T.1    Leonard, J.A.2    Gitter, A.J.3    Ball, R.D.4
  • 6
    • 0142185498 scopus 로고    scopus 로고
    • Coupled microphone-accelerometer sensor pair for dynamic noise reduction in MMG signal recording
    • J. Silva, T. Chau Coupled microphone-accelerometer sensor pair for dynamic noise reduction in MMG signal recording Electron Lett 39 2003 1496 1498
    • (2003) Electron Lett , vol.39 , pp. 1496-1498
    • Silva, J.1    Chau, T.2
  • 9
    • 85081433579 scopus 로고    scopus 로고
    • A mathematical model for source separation of MMG signals recorded with a coupled microphone-accelerometer sensor pair
    • In press.
    • Silva J, Chau T. A mathematical model for source separation of MMG signals recorded with a coupled microphone-accelerometer sensor pair. IEEE Trans Biomed Eng. In press.
    • IEEE Trans Biomed Eng
    • Silva, J.1    Chau, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.