메뉴 건너뛰기




Volumn 37, Issue 5, 2010, Pages 2074-2081

The noise power spectrum in CT with direct fan beam reconstruction

Author keywords

CT; Direct fan beam reconstruction; Noise power spectrum (NPS); Nonstationary noise

Indexed keywords

POWER SPECTRUM;

EID: 77952356186     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3378673     Document Type: Article
Times cited : (68)

References (29)
  • 1
    • 0003444152 scopus 로고    scopus 로고
    • 3rd ed. (Oxford University Press, New York)
    • R. Loudon, The Quantum Theory of Light, 3rd ed. (Oxford University Press, New York, 2000), p. 117.
    • (2000) The Quantum Theory of Light , pp. 117
    • Loudon, R.1
  • 2
    • 0017005599 scopus 로고
    • Statistical limitations in transaxial tomography
    • CBMDAW 0010-4825. 10.1016/0010-4825(76)90068-8
    • H. H. Barrett, S. K. Gordon, and R. S. Hershel, " Statistical limitations in transaxial tomography.," Comput. Biol. Med. CBMDAW 0010-4825 6 (4), 307-323 (1976). 10.1016/0010-4825(76)90068-8
    • (1976) Comput. Biol. Med. , vol.6 , Issue.4 , pp. 307-323
    • Barrett, H.H.1    Gordon, S.K.2    Hershel, R.S.3
  • 4
    • 0042874978 scopus 로고
    • Fan-beam-tomography noise theory
    • JOSAAH 0030-3941. 10.1364/JOSAA.3.000624
    • K. E. Bennett and R. L. Byer, " Fan-beam-tomography noise theory.," J. Opt. Soc. Am. JOSAAH 0030-3941 3 (5), 624-633 (1986). 10.1364/JOSAA.3.000624
    • (1986) J. Opt. Soc. Am. , vol.3 , Issue.5 , pp. 624-633
    • Bennett, K.E.1    Byer, R.L.2
  • 5
    • 0021461353 scopus 로고
    • Optical tomography: Experimental verification of noise theory
    • OPLEDP 0146-9592. 10.1364/OL.9.000270
    • K. E. Bennett and R. L. Byer, " Optical tomography: Experimental verification of noise theory.," Opt. Lett. OPLEDP 0146-9592 9 (7), 270-272 (1984). 10.1364/OL.9.000270
    • (1984) Opt. Lett. , vol.9 , Issue.7 , pp. 270-272
    • Bennett, K.E.1    Byer, R.L.2
  • 6
    • 0021477941 scopus 로고
    • Experimental optical fan beam tomography
    • APOPAI 0003-6935. 10.1364/AO.23.002678
    • K. E. Bennett, G. W. Faris, and R. L. Byer, " Experimental optical fan beam tomography.," Appl. Opt. APOPAI 0003-6935 23 (16), 2678-2685 (1984). 10.1364/AO.23.002678
    • (1984) Appl. Opt. , vol.23 , Issue.16 , pp. 2678-2685
    • Bennett, K.E.1    Faris, G.W.2    Byer, R.L.3
  • 7
    • 2942576194 scopus 로고    scopus 로고
    • Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography
    • ITMID4 0278-0062. 10.1109/TMI.2004.826943
    • G. L. Zeng, " Nonuniform noise propagation by using the ramp filter in fan-beam computed tomography.," IEEE Trans. Med. Imaging ITMID4 0278-0062 23 (6), 690-695 (2004). 10.1109/TMI.2004.826943
    • (2004) IEEE Trans. Med. Imaging , vol.23 , Issue.6 , pp. 690-695
    • Zeng, G.L.1
  • 8
    • 35148870232 scopus 로고    scopus 로고
    • A practical reconstruction algorithm for CT noise variance maps using FBP reconstruction
    • DOI 10.1117/12.713692, Medical Imaging 2007: Physics of Medical Imaging
    • L. Zhu and J. Starlack, " A practical reconstruction algorithm for CT noise variance maps using FBP reconstruction.," Proc. SPIE PSISDG 0277-786X 6510, 651023 (2007). 10.1117/12.713692 (Pubitemid 47550179)
    • (2007) Progress in Biomedical Optics and Imaging - Proceedings of SPIE , vol.6510 , Issue.PART 2 , pp. 651023
    • Lei, Z.1    StarLack, J.2
  • 9
    • 0036122063 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for computed radiography systems
    • DOI 10.1118/1.1449873
    • E. Samei and M. J. Flynn, " An experimental comparison of detector performance for computed radiography systems.," Med. Phys. MPHYA6 0094-2405 29 (4), 447-459 (2002). 10.1118/1.1449873 (Pubitemid 34408759)
    • (2002) Medical Physics , vol.29 , Issue.4 , pp. 447-459
    • Samei, E.1    Flynn, M.J.2
  • 10
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • DOI 10.1118/1.1561285
    • E. Samei and M. J. Flynn, " An experimental comparison of detector performance for direct and indirect digital radiography systems.," Med. Phys. MPHYA6 0094-2405 30 (4), 608-622 (2003). 10.1118/1.1561285 (Pubitemid 36443965)
    • (2003) Medical Physics , vol.30 , Issue.4 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 11
    • 0021812629 scopus 로고
    • SNR and DQE analysis of broad spectrum x-ray imaging
    • DOI 10.1088/0031-9155/30/6/002
    • M. J. Tapiovaara and R. F. Wagner, " SNR and DQE analysis of broad spectrum x-ray imaging.," Phys. Med. Biol. PHMBA7 0031-9155 30 (6), 519-529 (1985). 10.1088/0031-9155/30/6/002 (Pubitemid 15041525)
    • (1985) Physics in Medicine and Biology , vol.30 , Issue.6 , pp. 519-529
    • Tapiovaara, M.J.1    Wagner, R.F.2
  • 13
    • 0017800671 scopus 로고
    • The noise power spectrum in computed x-ray tomography
    • PHMBA7 0031-9155. 10.1088/0031-9155/23/3/008
    • S. J. Riederer, N. J. Pelc, and D. A. Chesler, " The noise power spectrum in computed x-ray tomography.," Phys. Med. Biol. PHMBA7 0031-9155 23 (3), 446-454 (1978). 10.1088/0031-9155/23/3/008
    • (1978) Phys. Med. Biol. , vol.23 , Issue.3 , pp. 446-454
    • Riederer, S.J.1    Pelc, N.J.2    Chesler, D.A.3
  • 14
    • 0018733995 scopus 로고
    • Detectability in computed tomographic images
    • DOI 10.1118/1.594534
    • K. M. Hanson, " Detectability in computed tomographic images.," Med. Phys. MPHYA6 0094-2405 6 (5), 441-451 (1979). 10.1118/1.594534 (Pubitemid 10244108)
    • (1979) Medical Physics , vol.6 , Issue.5 , pp. 441-451
    • Hanson, K.M.1
  • 15
    • 0021736468 scopus 로고
    • Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function
    • PHMBA7 0031-9155. 10.1088/0031-9155/29/11/003
    • K. Faulkner and B. M. Moores, " Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function.," Phys. Med. Biol. PHMBA7 0031-9155 29 (11), 1343-1352 (1984). 10.1088/0031-9155/29/11/003
    • (1984) Phys. Med. Biol. , vol.29 , Issue.11 , pp. 1343-1352
    • Faulkner, K.1    Moores, B.M.2
  • 16
    • 0023199089 scopus 로고
    • The noise power spectrum of CT images
    • PHMBA7 0031-9155. 10.1088/0031-9155/32/5/003
    • M. F. Kijewski and P. F. Judy, " The noise power spectrum of CT images.," Phys. Med. Biol. PHMBA7 0031-9155 32 (5), 565-575 (1987). 10.1088/0031-9155/32/5/003
    • (1987) Phys. Med. Biol. , vol.32 , Issue.5 , pp. 565-575
    • Kijewski, M.F.1    Judy, P.F.2
  • 18
    • 0032912583 scopus 로고    scopus 로고
    • Optimal noise control in and fast reconstruction of fan-beam computed tomography image
    • DOI 10.1118/1.598574
    • X. Pan, " Optimal noise control in and fast reconstruction of fan-beam computed tomography image.," Med. Phys. MPHYA6 0094-2405 26 (5), 689-697 (1999). 10.1118/1.598574 (Pubitemid 29227115)
    • (1999) Medical Physics , vol.26 , Issue.5 , pp. 689-697
    • Pan, X.1
  • 19
    • 0030866638 scopus 로고    scopus 로고
    • Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts
    • DOI 10.1118/1.598026
    • J. Hsieh, " Nonstationary noise characteristics of the helical scan and its impact on image quality and artifacts.," Med. Phys. MPHYA6 0094-2405 24 (9), 1375-1384 (1997). 10.1118/1.598026 (Pubitemid 27415068)
    • (1997) Medical Physics , vol.24 , Issue.9 , pp. 1375-1384
    • Hsieh, J.1
  • 20
    • 42649084336 scopus 로고    scopus 로고
    • Image covariance and lesion detectability in direct fan-beam x-ray computed tomography
    • DOI 10.1088/0031-9155/53/10/002, PII S0031915508643055
    • A. Wunderlich and F. Noo, " Image covariance and lesion detectability in direct fan-beam x-ray computed tomography.," Phys. Med. Biol. PHMBA7 0031-9155 53, 2471-2493 (2008). 10.1088/0031-9155/53/10/002 (Pubitemid 351595089)
    • (2008) Physics in Medicine and Biology , vol.53 , Issue.10 , pp. 2471-2493
    • Wunderlich, A.1    Noo, F.2
  • 21
    • 0037391657 scopus 로고    scopus 로고
    • Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography
    • DOI 10.1118/1.1556608
    • X. Pan and L. Yu, " Image reconstruction with shift-variant filtration and its implication for noise and resolution properties in fan-beam computed tomography.," Med. Phys. MPHYA6 0094-2405 30 (4), 590-600 (2003). 10.1118/1.1556608 (Pubitemid 36443963)
    • (2003) Medical Physics , vol.30 , Issue.4 , pp. 590-600
    • Pan, X.1    Yu, L.2
  • 22
    • 28044455874 scopus 로고    scopus 로고
    • An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction
    • DOI 10.1118/1.2064807
    • J. Wang, H. Lu, T. Li, and Z. Liang, " An alternative solution to the nonuniform noise propagation problem in fan-beam FBP image reconstruction.," Med. Phys. MPHYA6 0094-2405 32 (11), 3389-3394 (2005). 10.1118/1.2064807 (Pubitemid 41689292)
    • (2005) Medical Physics , vol.32 , Issue.11 , pp. 3389-3394
    • Wang, J.1    Lu, H.2    Li, T.3    Liang, Z.4
  • 23
    • 0033017006 scopus 로고    scopus 로고
    • CT image reconstruction from fan-parallel data
    • DOI 10.1118/1.598533
    • G. Besson, " CT image reconstruction from fan-parallel data.," Med. Phys. MPHYA6 0094-2405 26 (3), 415-426 (1999). 10.1118/1.598533 (Pubitemid 29136479)
    • (1999) Medical Physics , vol.26 , Issue.3 , pp. 415-426
    • Besson, G.1
  • 24
    • 56749159109 scopus 로고    scopus 로고
    • Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT
    • MPHYA6 0094-2405. 10.1118/1.3002414
    • D. J. Tward and J. H. Siewerdsen, " Cascaded systems analysis of the 3D noise transfer characteristics of flat-panel cone-beam CT.," Med. Phys. MPHYA6 0094-2405 35 (12), 5510-5529 (2008). 10.1118/1.3002414
    • (2008) Med. Phys. , vol.35 , Issue.12 , pp. 5510-5529
    • Tward, D.J.1    Siewerdsen, J.H.2
  • 25
    • 68149098899 scopus 로고    scopus 로고
    • Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling
    • MPHYA6 0094-2405. 10.1118/1.3166933
    • D. J. Tward and J. H. Siewerdsen, " Noise aliasing and the 3D NEQ of flat-panel cone-beam CT: Effect of 2D/3D apertures and sampling.," Med. Phys. MPHYA6 0094-2405 36 (8), 3830-3843 (2009). 10.1118/1.3166933
    • (2009) Med. Phys. , vol.36 , Issue.8 , pp. 3830-3843
    • Tward, D.J.1    Siewerdsen, J.H.2
  • 27
    • 1842865422 scopus 로고    scopus 로고
    • A framework for noise-power spectrum analysis of multidimensional images
    • DOI 10.1118/1.1513158
    • J. H. Siewerdsen, I. A. Cunningham, and D. A. Jaffray, " A framework for noise-power spectrum analysis of multidimensional images.," Med. Phys. MPHYA6 0094-2405 29 (11), 2655-2671 (2002). 10.1118/1.1513158 (Pubitemid 35375465)
    • (2002) Medical Physics , vol.29 , Issue.11 , pp. 2655-2671
    • Siewerdsen, J.H.1    Cunningham, I.A.2    Jaffray, D.A.3
  • 28
    • 0032692240 scopus 로고    scopus 로고
    • A simple theorem relating noise and patient dose in computed tomography
    • MPHYA6 0094-2405. 10.1118/1.598778
    • M. D. Harpen, " A simple theorem relating noise and patient dose in computed tomography.," Med. Phys. MPHYA6 0094-2405 26 (11), 2231-2234 (1999). 10.1118/1.598778
    • (1999) Med. Phys. , vol.26 , Issue.11 , pp. 2231-2234
    • Harpen, M.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.