메뉴 건너뛰기




Volumn 28, Issue 4, 2010, Pages 574-582

Respiratory noise correction using phase information

Author keywords

FMRI; Phase; Respiratory noise; RETROICOR

Indexed keywords

ARTICLE; BREATHING; BREATHING MECHANICS; CONTROLLED STUDY; DATA ANALYSIS; DIAGNOSTIC PROCEDURE; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; IMAGE PROCESSING; NOISE; PRIORITY JOURNAL; SIGNAL PROCESSING; TIME; TIME SERIES ANALYSIS;

EID: 77952290864     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2009.12.014     Document Type: Article
Times cited : (13)

References (17)
  • 3
    • 0030053163 scopus 로고    scopus 로고
    • Reduction of physiological fluctuations in fMRI using digital filters
    • Biswal B., DeYoe A.E., Hyde J.S. Reduction of physiological fluctuations in fMRI using digital filters. Magn Reson Med 1996, 35:107-113.
    • (1996) Magn Reson Med , vol.35 , pp. 107-113
    • Biswal, B.1    DeYoe, A.E.2    Hyde, J.S.3
  • 4
    • 0029118783 scopus 로고
    • P. E. Retrospective estimation and correction of physiological fluctuation in functional MRI
    • Hu X., Le T.H., Parrish T. P. E. Retrospective estimation and correction of physiological fluctuation in functional MRI. Magn Reson Med 1995, 34:201-212.
    • (1995) Magn Reson Med , vol.34 , pp. 201-212
    • Hu, X.1    Le, T.H.2    Parrish, T.3
  • 5
    • 0033934775 scopus 로고    scopus 로고
    • Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR
    • Glover G.H., Li T.Q., Ress D. Image-based method for retrospective correction of physiological motion effects in fMRI: RETROICOR. Magn Reson Med 2000, 44:162-167.
    • (2000) Magn Reson Med , vol.44 , pp. 162-167
    • Glover, G.H.1    Li, T.Q.2    Ress, D.3
  • 6
    • 0034904235 scopus 로고    scopus 로고
    • IMPACT: Image-Based Physiological Artifacts Estimation and Correction Technique for functional MRI
    • Chuang K.H., Chen J.H. IMPACT: Image-Based Physiological Artifacts Estimation and Correction Technique for functional MRI. Magn Reson Med 2001, 46:344-353.
    • (2001) Magn Reson Med , vol.46 , pp. 344-353
    • Chuang, K.H.1    Chen, J.H.2
  • 7
    • 0036136108 scopus 로고    scopus 로고
    • Postacquisition suppression of large-vessel BOLD signals in high-resolution fMRI
    • Menon R.S. Postacquisition suppression of large-vessel BOLD signals in high-resolution fMRI. Magn Reson Med 2002, 47:1-9.
    • (2002) Magn Reson Med , vol.47 , pp. 1-9
    • Menon, R.S.1
  • 8
    • 34447562908 scopus 로고    scopus 로고
    • Reducing the unwanted draining vein BOLD contribution in fMRI with statistical post-processing methods
    • Nencka A.S., Rowe D.B. Reducing the unwanted draining vein BOLD contribution in fMRI with statistical post-processing methods. Neuroimage 2007, 37:177-188.
    • (2007) Neuroimage , vol.37 , pp. 177-188
    • Nencka, A.S.1    Rowe, D.B.2
  • 9
    • 0008913870 scopus 로고    scopus 로고
    • Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data
    • Le T.H., Hu X. Retrospective estimation and correction of physiological artifacts in fMRI by direct extraction of physiological activity from MR data. Magn Reson Med 1996, 35:290-298.
    • (1996) Magn Reson Med , vol.35 , pp. 290-298
    • Le, T.H.1    Hu, X.2
  • 10
    • 0030701614 scopus 로고    scopus 로고
    • K-Space detection and correction of physiological artifacts in fMRI
    • Wowk B., McIntyre M.C., Saunders J.K. k-Space detection and correction of physiological artifacts in fMRI. Magn Reson Med 1997, 38:1029-1034.
    • (1997) Magn Reson Med , vol.38 , pp. 1029-1034
    • Wowk, B.1    McIntyre, M.C.2    Saunders, J.K.3
  • 11
    • 0035088894 scopus 로고    scopus 로고
    • Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data
    • Frank L.R., Buxton R.B., Wong E.C. Estimation of respiration-induced noise fluctuations from undersampled multislice fMRI data. Magn Reson Med 2001, 45:635-644.
    • (2001) Magn Reson Med , vol.45 , pp. 635-644
    • Frank, L.R.1    Buxton, R.B.2    Wong, E.C.3
  • 12
    • 0035739241 scopus 로고    scopus 로고
    • Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes
    • Raj D., Anderson A.W., Gore J.C. Respiratory effects in human functional magnetic resonance imaging due to bulk susceptibility changes. Phys Med Biol 2001, 46:3331-3340.
    • (2001) Phys Med Biol , vol.46 , pp. 3331-3340
    • Raj, D.1    Anderson, A.W.2    Gore, J.C.3
  • 13
    • 33746852686 scopus 로고    scopus 로고
    • Separating respiratory-variation- related fluctuations from neuronal-activity-related fluctuations in fMRI
    • Birn R.M., Diamond J.B., Smith M.A., Bandettini P.A. Separating respiratory-variation- related fluctuations from neuronal-activity-related fluctuations in fMRI. Neuroimage 2006, 31:1536-1548.
    • (2006) Neuroimage , vol.31 , pp. 1536-1548
    • Birn, R.M.1    Diamond, J.B.2    Smith, M.A.3    Bandettini, P.A.4
  • 14
    • 40649083494 scopus 로고    scopus 로고
    • The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration
    • Birn R.M., Smith M.A., Jones T.B., Bandettini P.A. The respiration response function: The temporal dynamics of fMRI signal fluctuations related to changes in respiration. Neuroimage 2008, 40:644-654.
    • (2008) Neuroimage , vol.40 , pp. 644-654
    • Birn, R.M.1    Smith, M.A.2    Jones, T.B.3    Bandettini, P.A.4
  • 17
    • 0030013529 scopus 로고    scopus 로고
    • The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds
    • Schenck J. The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. Med Phys 1996, 23:815-850.
    • (1996) Med Phys , vol.23 , pp. 815-850
    • Schenck, J.1