메뉴 건너뛰기




Volumn 34, Issue 5, 2010, Pages

A novel low temperature transcutaneous energy transfer system suitable for high power implantable medical devices: Performance and validation in sheep

Author keywords

Artificial hearts; Inductive power; Magnetic field; Transcutaneous energy transfer; Ventricular assist device; Wireless power

Indexed keywords

BIOMEDICAL EQUIPMENT; IMPLANTS (SURGICAL); MAGNETIC FIELDS; TEMPERATURE; TISSUE;

EID: 77952273752     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2009.00992.x     Document Type: Article
Times cited : (28)

References (14)
  • 1
    • 0033183867 scopus 로고    scopus 로고
    • A new structure transcutaneous transformer for artificial heart system
    • Zhao L, Foo CF, Tseng KJ. A new structure transcutaneous transformer for artificial heart system. IEEE Trans Magn 1999 35 : 3550 3552.
    • (1999) IEEE Trans Magn , vol.35 , pp. 3550-3552
    • Zhao, L.1    Foo, C.F.2    Tseng, K.J.3
  • 2
    • 33746002273 scopus 로고    scopus 로고
    • Left ventricular assist devices: New hope for patients with end stage heart failure
    • Milano CA, Lodge AJ, Blue LJ, et al. Left ventricular assist devices: new hope for patients with end stage heart failure. N C Med J 2006 67 : 110 115.
    • (2006) N C Med J , vol.67 , pp. 110-115
    • Milano, C.A.1    Lodge, A.J.2    Blue, L.J.3
  • 3
    • 77952275571 scopus 로고    scopus 로고
    • Early infections after MCSD implant in 455 patients: Incidence, location and outcome
    • Holman W, Kirklin J, Naftel D, et al. Early infections after MCSD implant in 455 patients: incidence, location and outcome. J Heart Lung Transplant 2009 28 : S155 S155.
    • (2009) J Heart Lung Transplant , vol.28
    • Holman, W.1    Kirklin, J.2    Naftel, D.3
  • 4
    • 77952245744 scopus 로고    scopus 로고
    • A frequency control method for regulating wireless power to implantable devices
    • Harbin, China
    • Ping S, Hu AP, Malpas S, Budgett D. A frequency control method for regulating wireless power to implantable devices. IEEE ICIEA conference, Harbin, China, 2007.
    • (2007) IEEE ICIEA conference
    • Ping, S.1    Hu, A.P.2    Malpas, S.3
  • 5
    • 34147129619 scopus 로고    scopus 로고
    • Regulation of cytochrome oxidase redox state during umbilical cord occlusion in preterm fetal sheep
    • Bennet L, Roelfsema V, Dean J, et al. Regulation of cytochrome oxidase redox state during umbilical cord occlusion in preterm fetal sheep. Am J Physiol Regul Integr Comp Physiol 2007 292 : R1569 76.
    • (2007) Am J Physiol Regul Integr Comp Physiol , vol.292 , pp. 1569-1576
    • Bennet, L.1    Roelfsema, V.2    Dean, J.3
  • 7
    • 0036429976 scopus 로고    scopus 로고
    • Powering an artificial heart: Birth of the inductively coupled-radio frequency system in 1960
    • Schuder JC. Powering an artificial heart: birth of the inductively coupled-radio frequency system in 1960. Artif Organs 2002 26 : 909 915.
    • (2002) Artif Organs , vol.26 , pp. 909-915
    • Schuder, J.C.1
  • 9
    • 68549132341 scopus 로고    scopus 로고
    • A transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device
    • Okamoto E, Yamamoto Y, Akasaka Y, Motomura T, Mitamura Y, Nosé Y. A transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device. Artif Organs 2009 33 : 622 626.
    • (2009) Artif Organs , vol.33 , pp. 622-626
    • Okamoto, E.1    Yamamoto, Y.2    Akasaka, Y.3    Motomura, T.4    Mitamura, Y.5    Nosé, Y.6
  • 10
    • 17144440033 scopus 로고    scopus 로고
    • The artificial heart - Past, present, and future
    • Zareba KM. The artificial heart - past, present, and future. Med Sci Monitor 2002 8 : RA72 77
    • (2002) Med Sci Monitor , vol.8 , pp. 72-77
    • Zareba, K.M.1
  • 11
    • 0030018063 scopus 로고    scopus 로고
    • Transcutaneous energy transfer with voltage regulation for rotary blood pumps.
    • Mussivand T, Holmes KS, Hum A, Keon WJ. Transcutaneous energy transfer with voltage regulation for rotary blood pumps. J Artificial Organs 1996 20 : 621 624.
    • (1996) J Artificial Organs , vol.20 , pp. 621-624
    • Mussivand, T.1    Holmes, K.S.2    Hum, A.3    Keon, W.J.4
  • 14
    • 13144297791 scopus 로고    scopus 로고
    • Transport lattice models of heat transport in skin with spatially heterogeneous, temperature-dependent perfusion
    • Available at
    • Gowrishankar TR, Stewart DA, Martin GT, Weaver JC. Transport lattice models of heat transport in skin with spatially heterogeneous, temperature-dependent perfusion. Bio Med Eng Online 2004 3. Available at: http://www.biomedical-engineering-online.com/content/3/1/42
    • (2004) Bio Med Eng Online , vol.3-3142
    • Gowrishankar, T.R.1    Stewart, D.A.2    Martin, G.T.3    Weaver, J.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.