-
1
-
-
78651036121
-
Application of mechanical heart and lung apparatus to cardiac surgery
-
Gibbon JH, Jr. Application of mechanical heart and lung apparatus to cardiac surgery. Minn Med 1954;37:171-80.
-
(1954)
Minn Med
, vol.37
, pp. 171-180
-
-
Gibbon J.H., Jr.1
-
2
-
-
84942489501
-
Artificial heart in the chest and use of polyurethane for making hearts, valves and aortas
-
Kolff WJ, Akutsu T, Dreyer B, Norton H. Artificial heart in the chest and use of polyurethane for making hearts, valves and aortas. Trans Am Soc Artif Intern Organs 1959;5:298-300.
-
(1959)
Trans Am Soc Artif Intern Organs
, vol.5
, pp. 298-300
-
-
Kolff, W.J.1
Akutsu, T.2
Dreyer, B.3
Norton, H.4
-
4
-
-
0000547648
-
High level electromagnetic energy transfer through a closed chest wall
-
Schuder JC, Stephenson HE, Jr., Townsend JF. High level electromagnetic energy transfer through a closed chest wall. IRE International Convention Record 1961;9:part 9, 119-26.
-
(1961)
IRE International Convention Record
, vol.9
, Issue.PART 9
, pp. 119-126
-
-
Schuder, J.C.1
Stephenson H.E., Jr.2
Townsend, J.F.3
-
5
-
-
0011429082
-
Energy transfer into a closed chest by means of stationary coupling coils and a portable high-power oscillator
-
Schuder JC, Stephenson HE, Jr., Townsend JF. Energy transfer into a closed chest by means of stationary coupling coils and a portable high-power oscillator. Trans Am Soc Artif Intern Organs 1961;7:327-31.
-
(1961)
Trans Am Soc Artif Intern Organs
, vol.7
, pp. 327-331
-
-
Schuder, J.C.1
Stephenson H.E., Jr.2
Townsend, J.F.3
-
6
-
-
0011389113
-
Response of dogs and mice to long-term exposure to the electromagnetic field required to power an artificial heart
-
Schuder JC, Owens JH, Stephenson HE, Jr., Mackenzie JW. Response of dogs and mice to long-term exposure to the electromagnetic field required to power an artificial heart. Trans Am Soc Artif Intern Organs 1968;14:291-5.
-
(1968)
Trans Am Soc Artif Intern Organs
, vol.14
, pp. 291-295
-
-
Schuder, J.C.1
Owens, J.H.2
Stephenson H.E., Jr.3
Mackenzie, J.W.4
-
7
-
-
0011386515
-
Life span of mice exposed to radio-frequency electromagnetic fields
-
Silverman HT, Miller IF, Salkind AJ, eds. Princeton, NJ: The Electrochemical Society, Inc.
-
Gold JH, Schuder JC, Townsend JF, Stephenson HE, Jr. Life span of mice exposed to radio-frequency electromagnetic fields. In: Silverman HT, Miller IF, Salkind AJ, eds. Electrochemical Bioscience and Bioengineering. Princeton, NJ: The Electrochemical Society, Inc., 1973:162-77.
-
(1973)
Electrochemical Bioscience and Bioengineering
, pp. 162-177
-
-
Gold, J.H.1
Schuder, J.C.2
Townsend, J.F.3
Stephenson H.E., Jr.4
-
8
-
-
0011488404
-
Energy transport into the closed chest from a set of very-large mutually orthogonal coils
-
Schuder JC, Stephenson HE, Jr. Energy transport into the closed chest from a set of very-large mutually orthogonal coils. Communication Electronics 1963;64:527-34.
-
(1963)
Communication Electronics
, vol.64
, pp. 527-534
-
-
Schuder, J.C.1
Stephenson H.E., Jr.2
-
9
-
-
0015083432
-
An inductively coupled RF system for the transmission of 1 kw of power through the skin
-
Schuder JC, Gold JH, Stephenson HE, Jr. An inductively coupled RF system for the transmission of 1 kw of power through the skin. IEEE Trans Biomed Eng 1971;BME-18:265-73.
-
(1971)
IEEE Trans Biomed Eng
, vol.BME-18
, pp. 265-273
-
-
Schuder, J.C.1
Gold, J.H.2
Stephenson H.E., Jr.3
-
10
-
-
0011477707
-
The use of a magnetic field to remotely power an implantable blood pump. Preliminary report
-
Kusserow BK. The use of a magnetic field to remotely power an implantable blood pump. Preliminary report. Trans Am Soc Artif Intern Organs 1960;6:292-4.
-
(1960)
Trans Am Soc Artif Intern Organs
, vol.6
, pp. 292-294
-
-
Kusserow, B.K.1
-
11
-
-
0014340444
-
The skin tunnel transformer - A new system that permits both high efficiency transfer of power and telemetry of data through the intact skin
-
Andren CF, Fadali MA, Gott VL, Topez SR. The skin tunnel transformer - A new system that permits both high efficiency transfer of power and telemetry of data through the intact skin. IEEE Trans Biomed Eng 1968;BME-15:278-80.
-
(1968)
IEEE Trans Biomed Eng
, vol.BME-15
, pp. 278-280
-
-
Andren, C.F.1
Fadali, M.A.2
Gott, V.L.3
Topez, S.R.4
-
12
-
-
0020971074
-
In vivo evaluation of a compact implantable left ventricular assist system (LVAS)
-
Miller PJ, Green GF, Chen H, Ramassamy DH, LaForge JS, Jassawalla JS, Ream AK, Oyer PE, Portner PM. In vivo evaluation of a compact implantable left ventricular assist system (LVAS). Trans Am Soc Artif Intern Organs 1983;29:551-5.
-
(1983)
Trans Am Soc Artif Intern Organs
, vol.29
, pp. 551-555
-
-
Miller, P.J.1
Green, G.F.2
Chen, H.3
Ramassamy, D.H.4
LaForge, J.S.5
Jassawalla, J.S.6
Ream, A.K.7
Oyer, P.E.8
Portner, P.M.9
-
14
-
-
0034326315
-
Infection and thrombosis in total artificial heart technology: Past and future challenges - A historical review
-
Conger JL, Inman RW, Tamez D, Frazier OH, Radovancevic B. Infection and thrombosis in total artificial heart technology: Past and future challenges - A historical review. ASAIO J 2000;46:S22-7.
-
(2000)
ASAIO J
, vol.46
-
-
Conger, J.L.1
Inman, R.W.2
Tamez, D.3
Frazier, O.H.4
Radovancevic, B.5
-
15
-
-
0034326870
-
Infectious complications associated with ventricular assist systems
-
Myers T J, Khan T, Frazier OH. Infectious complications associated with ventricular assist systems. ASAIO J 2000;46:S28-36.
-
(2000)
ASAIO J
, vol.46
-
-
Myers, T.J.1
Khan, T.2
Frazier, O.H.3
|