메뉴 건너뛰기




Volumn 20, Issue 4, 2010, Pages 958-966

Development and validation of a low dose simulator for computed tomography

Author keywords

Computed tomography; Computer simulation; Noise; Physics; Radiation; X ray

Indexed keywords

ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; CONTROLLED STUDY; DIAGNOSTIC VALUE; IMAGE QUALITY; PHANTOM; PRIORITY JOURNAL; PROCESS DEVELOPMENT; RADIATION DOSE; RADIATION EXPOSURE; SIMULATOR; VALIDATION PROCESS;

EID: 77952092192     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00330-009-1617-x     Document Type: Article
Times cited : (27)

References (14)
  • 2
    • 36549007486 scopus 로고    scopus 로고
    • Computed tomography - An increasing source of radiation exposure
    • DOI 10.1056/NEJMra072149
    • DJ Brenner EJ Hall 2007 Computed tomography-an increasing source of radiation exposure N Engl J Med 357 2277 2284 10.1056/NEJMra072149 1:CAS:528:DC%2BD2sXhsVSlurfF 18046031 (Pubitemid 350190758)
    • (2007) New England Journal of Medicine , vol.357 , Issue.22 , pp. 2277-2284
    • Brenner, D.J.1    Hall, E.J.2
  • 4
    • 62949173801 scopus 로고    scopus 로고
    • A technique for simulating the effect of dose reduction on image quality in digital chest radiography
    • 10.1007/s10278-008-9104-5 18259814
    • WJ Veldkamp LJ Kroft JP van Delft J Geleijns 2009 A technique for simulating the effect of dose reduction on image quality in digital chest radiography J Digit Imaging 22 114 125 10.1007/s10278-008-9104-5 18259814
    • (2009) J Digit Imaging , vol.22 , pp. 114-125
    • Veldkamp, W.J.1    Kroft, L.J.2    Van Delft, J.P.3    Geleijns, J.4
  • 5
    • 2342640860 scopus 로고    scopus 로고
    • The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: An example application to X-ray CT of the brain
    • DOI 10.1259/bjr/78576048
    • AJ Britten M Crotty H Kiremidjian A Grundy EJ Adam 2004 The addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain Br J Radiol 77 323 328 10.1259/bjr/78576048 1:STN:280:DC%2BD2c3gvFCitA%3D%3D 15107323 (Pubitemid 38579117)
    • (2004) British Journal of Radiology , vol.77 , Issue.916 , pp. 323-328
    • Britten, A.J.1    Crotty, M.2    Kiremidjian, H.3    Grundy, A.4    Adam, E.J.5
  • 10
    • 20744455342 scopus 로고    scopus 로고
    • Multi-detector row CT pulmonary angiography: Comparison of standard-dose and simulated low-dose techniques
    • DOI 10.1148/radiol.2361040190
    • D Tack M De V W Petit P Scillia P Muller C Suess PA Gevenois 2005 Multi-detector row CT pulmonary angiography: comparison of standard-dose and simulated low-dose techniques Radiology 236 318 325 10.1148/radiol.2361040190 15987983 (Pubitemid 40853329)
    • (2005) Radiology , vol.236 , Issue.1 , pp. 318-325
    • Tack, D.1    De Maertelaer, V.2    Petit, W.3    Scillia, P.4    Muller, P.5    Suess, C.6    Gevenois, P.A.7
  • 12
    • 34547272556 scopus 로고    scopus 로고
    • Application of the noise power spectrum in modern diagnostic MDCT: Part I. Measurement of noise power spectra and noise equivalent quanta
    • DOI 10.1088/0031-9155/52/14/002, PII S0031915507361927, 002
    • KL Boedeker VN Cooper MF Nitt-Gray 2007 Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta Phys Med Biol 52 4027 4046 10.1088/0031-9155/52/14/ 002 1:STN:280:DC%2BD2svkslSgsQ%3D%3D 17664593 (Pubitemid 47134624)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.14 , pp. 4027-4046
    • Boedeker, K.L.1    Cooper, V.N.2    McNitt-Gray, M.F.3
  • 13
    • 0019434272 scopus 로고
    • The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities
    • 10.1088/0031-9155/26/1/013 1:STN:280:DyaL3M3isVSqtA%3D%3D 7243862
    • PC Shrimpton BF Wall ES Fisher 1981 The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities Phys Med Biol 26 133 139 10.1088/0031-9155/26/1/013 1:STN:280:DyaL3M3isVSqtA%3D%3D 7243862
    • (1981) Phys Med Biol , vol.26 , pp. 133-139
    • Shrimpton, P.C.1    Wall, B.F.2    Fisher, E.S.3
  • 14
    • 27144559956 scopus 로고    scopus 로고
    • Appendicitis in children: Low-dose CT with a phantom-based simulation technique - Initial observations
    • DOI 10.1148/radiol.2372041642
    • NR Fefferman E Bomsztyk AM Yim R Rivera JB Amodio LP Pinkney NA Strubel ME Noz H Rusinek 2005 Appendicitis in children: low-dose CT with a phantom-based simulation technique-initial observations Radiology 237 641 646 10.1148/radiol.2372041642 16170015 (Pubitemid 41507906)
    • (2005) Radiology , vol.237 , Issue.2 , pp. 641-646
    • Fefferman, N.R.1    Bomsztyk, E.2    Yim, A.M.3    Rivera, R.4    Amodio, J.B.5    Pinkney, L.P.6    Strubel, N.A.7    Noz, M.E.8    Rusinek, H.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.