메뉴 건너뛰기




Volumn 46, Issue 4, 2010, Pages 469-478

Effect of regeneration on the thermo-ecological performance analysis and optimization of irreversible air refrigerators

Author keywords

[No Author keywords available]

Indexed keywords

COEFFICIENT OF PERFORMANCE; COMPARATIVE PERFORMANCE ANALYSIS; ECOLOGICAL COEFFICIENT OF PERFORMANCE; ECOLOGICAL DESIGN; ECOLOGICAL PERFORMANCE; EXERGETIC EFFICIENCY; EXPANSION PROCESS; FINITE TEMPERATURE DIFFERENCES; HEAT LEAKS; HEAT RESERVOIRS; HEAT SOURCES; INTERNAL IRREVERSIBILITY; ISENTROPIC COMPRESSION; OBJECTIVE FUNCTIONS; OPTIMAL CONDITIONS; REGENERATIVE LOSS; TEMPERATURE RATIO; THERMAL RESERVOIR;

EID: 77952010923     PISSN: 09477411     EISSN: 14321181     Source Type: Journal    
DOI: 10.1007/s00231-010-0593-7     Document Type: Article
Times cited : (21)

References (35)
  • 1
    • 0021483639 scopus 로고
    • Thermodynamics in finite time
    • 10.1063/1.2916405
    • B Andresen P Salamon RS Berry 1984 Thermodynamics in finite time Phys Today 9 62 70 10.1063/1.2916405
    • (1984) Phys Today , vol.9 , pp. 62-70
    • Andresen, B.1    Salamon, P.2    Berry, R.S.3
  • 2
    • 0000071830 scopus 로고    scopus 로고
    • Entropy generation minimization: The new thermodynamics of finite-size devices and finite-time processes
    • 10.1063/1.362674
    • A Bejan 1996 Entropy generation minimization: the new thermodynamics of finite-size devices and finite-time processes J Appl Phys 79 1191 1218 10.1063/1.362674
    • (1996) J Appl Phys , vol.79 , pp. 1191-1218
    • Bejan, A.1
  • 4
    • 0033282840 scopus 로고    scopus 로고
    • Finite time thermodynamic optimization or entropy generation minimization of energy systems
    • DOI 10.1515/JNETDY.1999.020
    • L Chen C Wu F Sun 1999 Finite time thermodynamic optimization or entropy generation minimization of energy systems J Non-Equil Therm 24 327 359 05156190 10.1515/JNETDY.1999.020 (Pubitemid 32132785)
    • (1999) Journal of Non-Equilibrium Thermodynamics , vol.24 , Issue.4 , pp. 327-359
    • Chen, L.1    Wu, C.2    Sun, F.3
  • 5
    • 1042275381 scopus 로고    scopus 로고
    • Optimization of thermal systems based on finite-time thermodynamics and thermoeconomics
    • 10.1016/j.pecs.2003.10.003
    • A Durmayaz OS Sogut B Sahin H Yavuz 2004 Optimization of thermal systems based on finite-time thermodynamics and thermoeconomics Prog Energy Combust Sci 30 175 217 10.1016/j.pecs.2003.10.003
    • (2004) Prog Energy Combust Sci , vol.30 , pp. 175-217
    • Durmayaz, A.1    Sogut, O.S.2    Sahin, B.3    Yavuz, H.4
  • 6
    • 0009176532 scopus 로고    scopus 로고
    • Progress on the development of miniature turbomachines for low capacity reverse Brayton cryocooler
    • McCormick JA (1996) Progress on the development of miniature turbomachines for low capacity reverse Brayton cryocooler. In: Proceedings of the 9th international cryocooler conference
    • (1996) Proceedings of the 9th International Cryocooler Conference
    • McCormick, J.A.1
  • 7
    • 1042293298 scopus 로고    scopus 로고
    • Heat exchanger effect on a gas refrigeration cycle
    • DOI 10.1016/0196-8904(96)00004-0
    • C Wu 1996 Heat exchanger effect on a gas refrigeration cycle Energy Convers Manag 37 1513 1516 10.1016/0196-8904(96)00004-0 (Pubitemid 126364672)
    • (1996) Energy Conversion and Management , vol.37 , Issue.10 , pp. 1513-1516
    • Wu, C.1
  • 8
    • 0030262482 scopus 로고    scopus 로고
    • Optimization of steady flow refrigeration cycles
    • C Wu L Chen F Sun 1996 Optimization of steady flow refrigeration cycles Int J Ambient Energy 17 199 206
    • (1996) Int J Ambient Energy , vol.17 , pp. 199-206
    • Wu, C.1    Chen, L.2    Sun, F.3
  • 9
    • 0031621853 scopus 로고    scopus 로고
    • Cooling load versus COP characteristics for an irreversible air refrigeration cycle
    • 10.1016/S0196-8904(96)00119-7
    • L Chen C Wu F Sun 1998 Cooling load versus COP characteristics for an irreversible air refrigeration cycle Energy Convers Manage 39 117 126 10.1016/S0196-8904(96)00119-7
    • (1998) Energy Convers Manage , vol.39 , pp. 117-126
    • Chen, L.1    Wu, C.2    Sun, F.3
  • 10
    • 0141802032 scopus 로고    scopus 로고
    • Cooling Load Density Analysis and Optimization for an Endoreversible Air Refrigerator
    • DOI 10.1023/A:1011902616949
    • S Zhou L Chen F Sun C Wu 2001 Cooling load density analysis and optimization for an endoreversible air refrigerator Open Syst Inf Dyn 8 147 155 1009.37019 10.1023/A:1011902616949 (Pubitemid 33678802)
    • (2001) Open Systems and Information Dynamics , vol.8 , Issue.2 , pp. 147-155
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 11
    • 0036572857 scopus 로고    scopus 로고
    • Optimum allocation of heat exchanger inventory of irreversible air refrigeration cycles
    • DOI 10.1238/Physica.Regular.065a00410
    • J Luo L Chen F Sun C Wu 2002 Optimum allocation of heat exchanger inventory of irreversible air refrigeration cycles Phys Scripta 65 410 415 10.1238/Physica.Regular.065a00410 (Pubitemid 34495330)
    • (2002) Physica Scripta , vol.65 , Issue.5 , pp. 410-415
    • Luo, J.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 12
    • 0036694510 scopus 로고    scopus 로고
    • Cooling load density characteristics of an endoreversible variable-temperature heat reservoir air refrigerator
    • 10.1002/er.826
    • S Zhou L Chen F Sun C Wu 2002 Cooling load density characteristics of an endoreversible variable-temperature heat reservoir air refrigerator Int J Energy Res 26 881 892 10.1002/er.826
    • (2002) Int J Energy Res , vol.26 , pp. 881-892
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 13
    • 0141578861 scopus 로고    scopus 로고
    • Cooling load density optimization of an irreversible simple Brayton refrigerator
    • 1014.80500 10.1023/A:1021854217387
    • S Zhou L Chen F Sun C Wu 2002 Cooling load density optimization of an irreversible simple Brayton refrigerator Open Syst Inf Dyn 9 325 337 1014.80500 10.1023/A:1021854217387
    • (2002) Open Syst Inf Dyn , vol.9 , pp. 325-337
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 14
    • 11844256632 scopus 로고    scopus 로고
    • Cooling load density performance of an irreversible simple air refrigerator coupled to variable-temperature heat reservoir
    • Nova Science, New York
    • Zhou S, Chen L, Sun F, Wu C (2004) Cooling load density performance of an irreversible simple air refrigerator coupled to variable-temperature heat reservoir. In: Advances in finite time thermodynamics: analysis and optimization, Nova Science, New York, p 193-206
    • (2004) Advances in Finite Time Thermodynamics: Analysis and Optimization , pp. 193-206
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 15
    • 31144447563 scopus 로고    scopus 로고
    • Performance optimization for an irreversible variable-temperature heat reservoir air refrigerator
    • L Chen S Zhou F Sun C Wu 2005 Performance optimization for an irreversible variable-temperature heat reservoir air refrigerator Int J Ambient Energy 26 180 190
    • (2005) Int J Ambient Energy , vol.26 , pp. 180-190
    • Chen, L.1    Zhou, S.2    Sun, F.3    Wu, C.4
  • 16
    • 12444293832 scopus 로고    scopus 로고
    • Exergetic efficiency optimization for an irreversible Brayton refrigeration cycle
    • DOI 10.1016/j.ijthermalsci.2004.09.003, PII S1290072904001929
    • CK Chen YF Su 2005 Exergetic efficiency optimization for an irreversible Brayton refrigeration cycle Int J Therm Sci 44 303 310 10.1016/j.ijthermalsci. 2004.09.003 (Pubitemid 40146355)
    • (2005) International Journal of Thermal Sciences , vol.44 , Issue.3 , pp. 303-310
    • Chen, C.-K.1    Su, Y.-F.2
  • 17
    • 33748797938 scopus 로고    scopus 로고
    • Cooling load and coefficient of performance optimizations for real air-refrigerators
    • DOI 10.1016/j.apenergy.2006.03.003, PII S0306261906000419
    • Y Tu L Chen F Sun C Wu 2006 Cooling load and coefficient of performance optimizations for real air-refrigerators Appl Energy 83 1289 1306 10.1016/j.apenergy.2006.03.003 (Pubitemid 44415322)
    • (2006) Applied Energy , vol.83 , Issue.12 , pp. 1289-1306
    • Tu, Y.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 18
    • 0000330242 scopus 로고    scopus 로고
    • Finite time thermodynamic performance of an isentropic closed regenerated Brayton refrigeration cycle
    • L Chen C Wu F Sun 1997 Finite time thermodynamic performance of an isentropic closed regenerated Brayton refrigeration cycle Int J Energy Environ Econ 4 261 274
    • (1997) Int J Energy Environ Econ , vol.4 , pp. 261-274
    • Chen, L.1    Wu, C.2    Sun, F.3
  • 19
    • 0035819827 scopus 로고    scopus 로고
    • Performance of heat-transfer irreversible regenerated Brayton refrigerators
    • DOI 10.1088/0022-3727/34/5/322, PII S0022372701193666
    • L Chen S Zhou F Sun C Wu 2001 Performance of heat-transfer irreversible regenerated Brayton refrigerators J Phys D Appl Phys 34 830 837 10.1088/0022-3727/34/5/322 (Pubitemid 32259389)
    • (2001) Journal of Physics D: Applied Physics , vol.34 , Issue.5 , pp. 830-837
    • Chen, L.1    Zhou, S.2    Sun, F.3    Wu, C.4
  • 20
    • 0141731383 scopus 로고    scopus 로고
    • Theoretical optimization of a regenerated air refrigerator
    • 10.1088/0022-3727/36/18/020
    • S Zhou L Chen F Sun C Wu 2003 Theoretical optimization of a regenerated air refrigerator J Phys D Appl Phys 36 2304 2311 10.1088/0022-3727/36/18/020
    • (2003) J Phys D Appl Phys , vol.36 , pp. 2304-2311
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 21
    • 1942455907 scopus 로고    scopus 로고
    • Cooling-load density optimization for a regenerated air refrigerator
    • DOI 10.1016/j.apenergy.2003.08.008, PII S0306261903001818
    • S Zhou L Chen F Sun C Wu 2004 Cooling-load density optimization for a regenerated air refrigerator Appl Energy 78 315 328 10.1016/j.apenergy.2003.08. 008 (Pubitemid 38522416)
    • (2004) Applied Energy , vol.78 , Issue.3 , pp. 315-328
    • Zhou, S.1    Chen, L.2    Sun, F.3    Wu, C.4
  • 22
    • 20344400370 scopus 로고    scopus 로고
    • Parametric optimum analysis of an irreversible regenerative magnetic Brayton refrigeration cycle
    • DOI 10.1016/j.physb.2005.03.030, PII S0921452605006460
    • Yang Y, Chen J, He J, Brück E (2005) Parametric optimum analysis of an irreversible regenerative magnetic Brayton refrigeration cycle. Physica B 364:33-42 (Pubitemid 40786425)
    • (2005) Physica B: Condensed Matter , vol.364 , Issue.1-4 , pp. 33-42
    • Yang, Y.1    Chen, J.2    He, J.3    Bruck, E.4
  • 23
    • 27944486025 scopus 로고    scopus 로고
    • Influence of regeneration on the performance of a Brayton refrigeration-cycle working with an ideal Bose-gas
    • DOI 10.1016/j.apenergy.2005.01.004, PII S0306261905000061
    • Y Yang B Lin J Chen 2006 Influence of regeneration on the performance of a Brayton refrigeration-cycle working with an ideal Bose-gas Appl Energy 83 99 112 10.1016/j.apenergy.2005.01.004 (Pubitemid 41681944)
    • (2006) Applied Energy , vol.83 , Issue.2 , pp. 99-112
    • Yang, Y.1    Lin, B.2    Chen, J.3
  • 24
    • 33745483132 scopus 로고    scopus 로고
    • The performance characteristics of an irreversible regenerative quantum refrigeration cycle
    • DOI 10.1088/0031-8949/73/1/007, PII S003189490610676007, 007
    • Y Zhang B Lin J Chen 2006 The performance characteristics of an irreversible regenerative quantum refrigeration cycle J Phys D Appl Phys 73 48 55 1117.82022 (Pubitemid 43959039)
    • (2006) Physica Scripta , vol.73 , Issue.1 , pp. 48-55
    • Zhang, Y.1    Lin, B.2    Chen, J.3
  • 25
    • 33748066015 scopus 로고    scopus 로고
    • A new thermoeconomic approach and parametric study of an irreversible regenerative Brayton refrigeration cycle
    • DOI 10.1016/j.ijrefrig.2006.01.003, PII S0140700706000338
    • SK Tyagi GM Chen Q Wang SC Kaushik 2006 A new thermoeconomic approach and parametric study of an irreversible regenerative Brayton refrigeration cycle Int J Refrigeration 29 1167 1174 10.1016/j.ijrefrig.2006.01.003 (Pubitemid 44301475)
    • (2006) International Journal of Refrigeration , vol.29 , Issue.7 , pp. 1167-1174
    • Tyagi, S.K.1    Chen, G.M.2    Wang, Q.3    Kaushik, S.C.4
  • 26
    • 33749660843 scopus 로고    scopus 로고
    • Comparison on the optimum performances of the irreversible Brayton refrigeration cycles with regeneration and non-regeneration
    • DOI 10.1016/j.applthermaleng.2006.07.012, PII S1359431106002584
    • Y Zhang J Chen J He C Wu 2007 Comparison on the optimum performances of the irreversible Brayton refrigeration cycles with regeneration and non-regeneration Appl Therm Eng 27 401 407 1150.93352 10.1016/j.applthermaleng. 2006.07.012 (Pubitemid 44557157)
    • (2007) Applied Thermal Engineering , vol.27 , Issue.2-3 , pp. 401-407
    • Zhang, Y.1    Chen, J.2    He, J.3    Wu, C.4
  • 27
    • 0033871941 scopus 로고    scopus 로고
    • Ecological optimization criterion for an irreversible three-heat-source refrigerator
    • DOI 10.1016/S0306-2619(99)00134-8
    • Z Yan G Lin 2000 Ecological optimization criterion for an irreversible three-heat-source refrigerator Appl Energy 66 213 224 10.1016/S0306-2619(99) 00134-8 (Pubitemid 30585798)
    • (2000) Applied Energy , vol.66 , Issue.3 , pp. 213-224
    • Yan, Z.1    Lin, G.2
  • 28
    • 0036832881 scopus 로고    scopus 로고
    • Ecological optimization of a multi-stage irreversible combined refrigeration system
    • DOI 10.1016/S0196-8904(01)00176-5, PII S0196890401001765
    • J Chen X Chen C Wu 2002 Ecological optimization of a multi-stage irreversible combined refrigeration system Energy Convers Manage 43 2379 2393 10.1016/S0196-8904(01)00176-5 (Pubitemid 34772399)
    • (2002) Energy Conversion and Management , vol.43 , Issue.17 , pp. 2379-2393
    • Chen, J.1    Chen, X.2    Wu, C.3
  • 29
    • 33847128973 scopus 로고
    • An ecological optimization criterion for finite-time heat engines
    • 10.1063/1.347562
    • F Angulo-Brown 1991 An ecological optimization criterion for finite-time heat engines J Appl Phys 69 7465 10.1063/1.347562
    • (1991) J Appl Phys , vol.69 , pp. 7465
    • Angulo-Brown, F.1
  • 30
    • 33847149643 scopus 로고    scopus 로고
    • Performance optimization of irreversible refrigerators based on a new thermo-ecological criterion
    • DOI 10.1016/j.ijrefrig.2006.07.002, PII S0140700706001447
    • Y Ust B Sahin 2007 Performance optimization of irreversible refrigerators based on a new thermo-ecological criterion Int J Refrigeration 30 527 534 10.1016/j.ijrefrig.2006.07.002 (Pubitemid 46281321)
    • (2007) International Journal of Refrigeration , vol.30 , Issue.3 , pp. 527-534
    • Ust, Y.1    Sahin, B.2
  • 31
    • 53549103589 scopus 로고    scopus 로고
    • Performance analysis and optimization of irreversible air refrigeration cycles based on ecological coefficient of performance criterion
    • 10.1016/j.applthermaleng.2008.01.024
    • Y Ust 2009 Performance analysis and optimization of irreversible air refrigeration cycles based on ecological coefficient of performance criterion Appl Therm Eng 29 47 55 10.1016/j.applthermaleng.2008.01.024
    • (2009) Appl Therm Eng , vol.29 , pp. 47-55
    • Ust, Y.1
  • 34
    • 0024029323 scopus 로고
    • Theory of heat transfer-irreversible power plants
    • DOI 10.1016/0017-9310(88)90064-6
    • A Bejan 1988 Theory of heat transfer-irreversible power plants Int JHeat Mass Transf 31 1211 1219 10.1016/0017-9310(88)90064-6 (Pubitemid 18650670)
    • (1988) International Journal of Heat and Mass Transfer , vol.31 , Issue.6 , pp. 1211-1219
    • Bejan, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.