3
-
-
37849021671
-
Wirksamkeit der manuellen Reinigung von Endoskopen
-
Cronmiller JR, Kim CH, Cuminale SA, Antloga KM, McDonnell GE: Wirksamkeit der manuellen Reinigung von Endoskopen, Zentr Steril 2006; 14(5): 99-104.
-
(2006)
Zentr Steril
, vol.14
, Issue.5
, pp. 99-104
-
-
Cronmiller, J.R.1
Kim, C.H.2
Cuminale, S.A.3
Antloga, K.M.4
McDonnell, G.E.5
-
4
-
-
0031436990
-
Natural bioburden levels detected on rigid lumened medical devices before and after cleaning
-
DOI 10.1016/S0196-6553(97)90070-5
-
Chan-Myers H, McAlister D, Antonoplos P: Natural bioburden levels detected on rigid lumened medical devices before and after cleaning. Am J Infect Control 1997; 25(6): 471-476. (Pubitemid 28023000)
-
(1997)
American Journal of Infection Control
, vol.25
, Issue.6
, pp. 471-476
-
-
Chan-Myers, H.1
McAlister, D.2
Antonoplos, P.3
-
5
-
-
0032862918
-
Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning
-
DOI 10.1016/S0196-6553(99)70004-0
-
Alfa MJ, Degagne P, Olson N: Worst-case soiling levels for patient-used flexible endoscopes before and after cleaning. Am J Infect Control 1999; 27(5): 392-401. (Pubitemid 29480630)
-
(1999)
American Journal of Infection Control
, vol.27
, Issue.5
, pp. 392-401
-
-
Alfa, M.J.1
Degagne, P.2
Olson, N.3
-
6
-
-
0025856705
-
What standards should we use for the disinfection of large equipment?
-
Miles RS: What standards should we use for the disinfection of large equipment? J Hosp Infect 1991; 18 Suppl A: 264-273.
-
(1991)
J Hosp Infect
, vol.18
, Issue.SUPPL. A
, pp. 264-273
-
-
Miles, R.S.1
-
7
-
-
77952000603
-
Health Technical Memorandum 2030
-
The Stationery Office, London. ISBN 0-11-322071-322075
-
Health Technical Memorandum 2030, Washer-disinfectors - Validation and verification - The Stationery Office, London. 1997 ISBN 0-11-322071-322075
-
(1997)
Washer-disinfectors - Validation and Verification
-
-
-
8
-
-
0034980934
-
A new hydrogen peroxide-based medical-device detergent with germicidal properties: Comparison with enzymatic cleaners
-
Alfa MJ, Jackson M: A new hydrogen peroxide-based medical-device detergent with germicidal properties: comparison with enzymatic cleaners. Am J Infect Control 2001; 29(3): 168-177.
-
(2001)
Am J Infect Control
, vol.29
, Issue.3
, pp. 168-177
-
-
Alfa, M.J.1
Jackson, M.2
-
9
-
-
77952007333
-
Ein Vergleich der in ISO/TS 15883-5 veröffentlichten Prüfanschmutzungen für chirurgische Instrumente
-
Crutwell M: Ein Vergleich der in ISO/TS 15883-5 veröffentlichten Prüfanschmutzungen für chirurgische Instrumente. Zentr Steril 2008; 16(4): 261-265.
-
(2008)
Zentr Steril
, vol.16
, Issue.4
, pp. 261-265
-
-
Crutwell, M.1
-
10
-
-
71849104860
-
Protein measurement with the Folin phenol reagent
-
Lowry OR, Roserbrough N H, Farr AL, Randall RJ: Protein measurement with the Folin phenol reagent. J Biol Chem 1951; 193(1): 256-275.
-
(1951)
J Biol Chem
, vol.193
, Issue.1
, pp. 256-275
-
-
Lowry, O.R.1
Roserbrough, N.H.2
Farr, A.L.3
Randall, R.J.4
-
11
-
-
33749946901
-
Colorimetric method for determination of sugar and related substance
-
Dubois M, Gilles KA, Hamilton JK, Rebers PA, Smith F: Colorimetric method for determination of sugar and related substance. Anal Chem 1956; 28(3): 350-356.
-
(1956)
Anal Chem
, vol.28
, Issue.3
, pp. 350-356
-
-
Dubois, M.1
Gilles, K.A.2
Hamilton, J.K.3
Rebers, P.A.4
Smith, F.5
-
12
-
-
77951984981
-
Human Medicines Evaluation Unit. Validation of Analytical Procedures ICH Topic Q2B Validation of Analytical Procedures: Methodology
-
European Agency for the Evaluation of Medicinal Products. November
-
European Agency for the Evaluation of Medicinal Products. Human Medicines Evaluation Unit. Validation of Analytical Procedures ICH Topic Q2B Validation of Analytical Procedures: Methodology. Step 4, Consensus Guideline, 6. November 1996.
-
(1996)
Step 4, Consensus Guideline
, vol.6
-
-
-
13
-
-
0345304084
-
Désinfection d'un biofilm mixte: Efficacité compare du chlore, du formol, de l'acide peracétique, du peroxide d'hydrogène et de l'association acide peracétique/peroxide d'hydrogène
-
Alasri A, Moal JF, Roques C, Michel G, Cabassud C, Aptel P: Désinfection d'un biofilm mixte: efficacité compare du chlore, du formol, de l'acide peracétique, du peroxide d'hydrogène et de l'association acide peracétique/peroxide d'hydrogène. Sci Tech Eau 1992; 25: 461-467
-
(1992)
Sci Tech Eau
, vol.25
, pp. 461-467
-
-
Alasri, A.1
Moal, J.F.2
Roques, C.3
Michel, G.4
Cabassud, C.5
Aptel, P.6
-
14
-
-
0030880501
-
Automatic washer disinfector for flexible endoscopes: A new evaluation process
-
Pineau L, Roques C, Luc J, Michel G: Automatic washer disinfector for flexible endoscopes: a new evaluation process. Endoscopy 1997; 29: 372-379. (Pubitemid 27370856)
-
(1997)
Endoscopy
, vol.29
, Issue.5
, pp. 372-379
-
-
Pineau, L.1
Roques, C.2
Luc, J.3
Michel, G.4
-
15
-
-
0034012397
-
Comparative investigations of the molecular properties of detergents and protein-detergent complexes
-
Durchschlag H, Tiefenbach KJ, Weber R, Kuchenmüller B, Jaenicke R: Comparative investigations of the molecular properties of detergents and protein-detergent complexes. Colloid Polym Sci 2000; 278: 312-320. (Pubitemid 30229753)
-
(2000)
Colloid and Polymer Science
, vol.278
, Issue.4
, pp. 312-320
-
-
Durchschlag, H.1
Tiefenbach, K.-J.2
Weber, R.3
Kuchenmuller, B.4
Jaenicke, R.5
-
16
-
-
10444275571
-
Electrochemical impedance spectroscopy study of the adsorption behaviour of a-lactalbumin and b-casein at stainless steel
-
Cosman NP, Fatih K, Roscoe JD: Electrochemical impedance spectroscopy study of the adsorption behaviour of a-lactalbumin and b-casein at stainless steel. J Electroanal Chem 2005; 574: 261-271.
-
(2005)
J Electroanal Chem
, vol.574
, pp. 261-271
-
-
Cosman, N.P.1
Fatih, K.2
Roscoe, J.D.3
-
17
-
-
0002106145
-
Beta-lactoglobulin fouling and its removal upon rinsing and by SDS as influenced by surface characteristics, temperature and adsorption time
-
Karlsson CAC, Wahlgreen MC, Trägardh AC: Beta-lactoglobulin fouling and its removal upon rinsing and by SDS as influenced by surface characteristics, temperature and adsorption time. J Food Eng 1996; 30: 43-60.
-
(1996)
J Food Eng
, vol.30
, pp. 43-60
-
-
Karlsson, C.A.C.1
Wahlgreen, M.C.2
Trägardh, A.C.3
-
18
-
-
3142753539
-
Platinium oxidation and its effect on concanavalin a adsorption
-
Diniz FB, Ueta RR: Platinium oxidation and its effect on concanavalin A adsorption. Electrochim Acta 2004; 49: 4281-4286.
-
(2004)
Electrochim Acta
, vol.49
, pp. 4281-4286
-
-
Diniz, F.B.1
Ueta, R.R.2
-
19
-
-
37849012629
-
Wirksame Reinigungsverfahren zur Verringerung des Risikos einer Prionenübertragung durch chirurgische Instrumente
-
Fichet G, Harrison J, McDonnell G: Wirksame Reinigungsverfahren zur Verringerung des Risikos einer Prionenübertragung durch chirurgische Instrumente. Zentr Steril 2007; 15(6): 418-437.
-
(2007)
Zentr Steril
, vol.15
, Issue.6
, pp. 418-437
-
-
Fichet, G.1
Harrison, J.2
McDonnell, G.3
-
20
-
-
85102482584
-
-
Wiley-Blackwell
-
McDonnell GE: Antisepsis, Disinfection, and Sterilization: Types, Action, and Resistance. Wiley-Blackwell, 2007: 361ff.
-
(2007)
Antisepsis, Disinfection, and Sterilization: Types, Action, and Resistance
-
-
McDonnell, G.E.1
-
21
-
-
1942516366
-
Reprocessing endoscopes: National recommendations with a special emphasis on cleaning - The German perspective
-
Heeg P: Reprocessing endoscopes: national recommendations with a special emphasis on cleaning - the German perspective. J Hosp Infect 2004; 56(Suppl. 2): S23-S26.
-
(2004)
J Hosp Infect
, vol.56
, Issue.SUPPL. 2
-
-
Heeg, P.1
-
22
-
-
1942516358
-
Reprocessing endoscopes: United States perspectives
-
Rutala BD, Weber DJ: Reprocessing endoscopes: United States perspectives. J Hosp Infect 2004; 56(suppl2): S27-S39.
-
(2004)
J Hosp Infect
, vol.56
, Issue.SUPPL. 2
-
-
Rutala, B.D.1
Weber, D.J.2
-
23
-
-
33744810095
-
A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure
-
DOI 10.1016/j.ajic.2005.08.007, PII S0196655305008448
-
Bisset L, Cossart YE, Selby W et al: A prospective study of the efficacy of routine decontamination for gastrointestinal endoscopes and the risk factors for failure. Am J Infect Control 2006; 34(5), 5: 274-280.. (Pubitemid 43833469)
-
(2006)
American Journal of Infection Control
, vol.34
, Issue.5
, pp. 274-280
-
-
Bisset, L.1
Cossart, Y.E.2
Selby, W.3
West, R.4
Catterson, D.5
O'Hara, K.6
Vickery, K.7
|