메뉴 건너뛰기




Volumn 47, Issue 3, 2010, Pages 167-174

An automated cryogenic current comparator resistance ratio bridge for routine resistance measurements

Author keywords

[No Author keywords available]

Indexed keywords

ALLAN DEVIATION; CRYOGENIC CURRENT COMPARATOR; LOW-LOSS LIQUIDS; NATIONAL METROLOGY INSTITUTES; NOISE SOURCE; RESISTANCE MEASUREMENT; RESISTANCE RATIO; SERVO CONTROL; STORAGE VESSEL; TYPE II;

EID: 77951998393     PISSN: 00261394     EISSN: 16817575     Source Type: Journal    
DOI: 10.1088/0026-1394/47/3/007     Document Type: Article
Times cited : (38)

References (16)
  • 1
    • 0015433249 scopus 로고
    • Precise low temperature dc ratio transformer
    • Harvey I K A 1972 Precise low temperature dc ratio transformer Rev. Sci. Instrum. 43 1626-9
    • (1972) Rev. Sci. Instrum. , vol.43 , Issue.11 , pp. 1626-1629
    • Harvey, I.K.A.1
  • 2
    • 0016326439 scopus 로고
    • A low-temperature direct-current comparator bridge
    • Sullivan D B and Dzuiba R F 1974 A low-temperature direct-current comparator bridge IEEE Trans. Instrum. Meas. 23 256-60
    • (1974) IEEE Trans. Instrum. Meas. , vol.23 , Issue.4 , pp. 256-260
    • Sullivan, D.B.1    Dzuiba, R.F.2
  • 3
    • 0026863392 scopus 로고
    • The role of the fundamental constants of physics in metrology
    • Petley B W 1992 The role of the fundamental constants of physics in metrology Metrologia 29 95-112
    • (1992) Metrologia , vol.29 , Issue.2 , pp. 95-112
    • Petley, B.W.1
  • 8
    • 0018060314 scopus 로고
    • Double constant current source for cryogenic current comparators and its applications
    • Delahaye F A 1978 Double constant current source for cryogenic current comparators and its applications IEEE Trans. Instrum. Meas. 27 426-9
    • (1978) IEEE Trans. Instrum. Meas. , vol.27 , Issue.4 , pp. 426-429
    • Delahaye, F.A.1
  • 15
    • 0033707379 scopus 로고    scopus 로고
    • Using power spectra and Allan variances to characterise the noise of Zener-diode voltage standards
    • Witt T J and Reymann D 2000 Using power spectra and Allan variances to characterise the noise of Zener-diode voltage standards IEE Proc.-Sci. Meas. Technol. 147 177-82
    • (2000) IEE Proc.-Sci. Meas. Technol. , vol.147 , Issue.4 , pp. 177-182
    • Witt, T.J.1    Reymann, D.2
  • 16
    • 0029288056 scopus 로고
    • Frequency dependence of 100 Ω standard resistors measured with a CCC-based AC resistance bridge
    • Sepp H, Satrapinski T, Varpula T and Saari J-M 1995 Frequency dependence of 100 Ω standard resistors measured with a CCC-based AC resistance bridge IEEE Trans. Instrum. Meas. 44 276-80
    • (1995) IEEE Trans. Instrum. Meas. , vol.44 , Issue.2 , pp. 276-280
    • Sepp, H.1    Satrapinski, T.2    Varpula, T.3    Saari, J.-M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.