1
-
-
0023260479
-
Normal pressure hydrocephalus in children and young adults
-
Barnett GH, Hahn JF, Palmer J: Normal pressure hydrocephalus in children and young adults. Neurosurgery 1987; 20: 904-907.
-
(1987)
Neurosurgery
, vol.20
, pp. 904-907
-
-
Barnett, G.H.1
Hahn, J.F.2
Palmer, J.3
-
2
-
-
0028357712
-
The use of the Codman-Medos programmable Hakim valve in the management of patients with hydrocephalus: Illustrative cases
-
Black PM, Hakim R, Bailey NO: The use of the Codman-Medos programmable Hakim valve in the management of patients with hydrocephalus: illustrative cases. Neurosurgery 1994; 34: 1110-1113.
-
(1994)
Neurosurgery
, vol.34
, pp. 1110-1113
-
-
Black, P.M.1
Hakim, R.2
Bailey, N.O.3
-
3
-
-
0018176654
-
Overdrainage phenomena in shunt treated hydrocephalus
-
Faulhauer K, Schmitz P: Overdrainage phenomena in shunt treated hydrocephalus. Acta Neurochir 1978; 45: 89-101.
-
(1978)
Acta Neurochir
, vol.45
, pp. 89-101
-
-
Faulhauer, K.1
Schmitz, P.2
-
4
-
-
0015856726
-
Hydraulic and mechanical mismatching of valve shunts used in the treatment of hydrocephalus: The need for a servovalve shunt
-
Hakim S: Hydraulic and mechanical mismatching of valve shunts used in the treatment of hydrocephalus: the need for a servovalve shunt. Dev Med Child Neurol 1973; 15: 646-653.
-
(1973)
Dev Med Child Neurol
, vol.15
, pp. 646-653
-
-
Hakim, S.1
-
5
-
-
0025529761
-
Ventricular volume in infantile hydrocephalus and its relationship to intracranial pressure and cerebrospinal fluid clearance before and after treatment: A preliminary study
-
Maixner WJ, Morgan MK, Besser M, Johnston IH: Ventricular volume in infantile hydrocephalus and its relationship to intracranial pressure and cerebrospinal fluid clearance before and after treatment: a preliminary study. Pediatr Neurosurg 1990; 16: 191-196.
-
(1990)
Pediatr Neurosurg
, vol.16
, pp. 191-196
-
-
Maixner, W.J.1
Morgan, M.K.2
Besser, M.3
Johnston, I.H.4
-
6
-
-
0028147287
-
The usefulness of mathematical modeling in hydrocephalus research
-
Rekate HL: The usefulness of mathematical modeling in hydrocephalus research. Childs Nerv Syst 1994; 10: 13-18.
-
(1994)
Childs Nerv Syst
, vol.10
, pp. 13-18
-
-
Rekate, H.L.1
-
7
-
-
0031919223
-
Dutch Normal-Pressure Hydrocephalus Study: Randomized comparison of low- and medium-pressure shunts
-
Boon AJ, Tans JT, Delwel EJ, Egeler-Peerdeman SM, Hanlo PW, Wurzer HA, Avezaat CJ, de Jong DA, Gooskens RH, Hermans J: Dutch Normal-Pressure Hydrocephalus Study: randomized comparison of low- and medium-pressure shunts. J Neurosurg 1998; 88: 490-495.
-
(1998)
J Neurosurg
, vol.88
, pp. 490-495
-
-
Boon, A.J.1
Tans, J.T.2
Delwel, E.J.3
Egeler-Peerdeman, S.M.4
Hanlo, P.W.5
Wurzer, H.A.6
Avezaat, C.J.7
De Jong, D.A.8
Gooskens, R.H.9
Hermans, J.10
-
8
-
-
0021160099
-
Treatment of normal pressure hydrocephalus with low versus medium pressure cerebrospinal fluid shunts
-
McQuarrie IG, Saint-Louis L, Scherer PB: Treatment of normal pressure hydrocephalus with low versus medium pressure cerebrospinal fluid shunts. Neurosurgery 1984; 15: 484-488.
-
(1984)
Neurosurgery
, vol.15
, pp. 484-488
-
-
McQuarrie, I.G.1
Saint-Louis, L.2
Scherer, P.B.3
-
9
-
-
0037373558
-
Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus
-
Zemack G, Bellner J, Siesjö P, Strömblad LG, Romner B: Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus. J Neurosurg 2003; 98: 471-476.
-
(2003)
J Neurosurg
, vol.98
, pp. 471-476
-
-
Zemack, G.1
Bellner, J.2
Siesjö, P.3
Strömblad, L.G.4
Romner, B.5
-
10
-
-
0034040516
-
Seven years of clinical experience with the programmable Codman Hakim valve: A retrospective study of 583 patients
-
Zemack G, Romner B: Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients. J Neurosurg 2000; 92: 941-948.
-
(2000)
J Neurosurg
, vol.92
, pp. 941-948
-
-
Zemack, G.1
Romner, B.2
-
11
-
-
0032764025
-
A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus
-
Hakim- Medos Investigator Group discussion 1408-1411
-
Pollack IF, Albright AL, Adelson PD: A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus. Hakim- Medos Investigator Group. Neurosurgery 1999; 45: 1399-1408, discussion 1408-1411.
-
(1999)
Neurosurgery
, vol.45
, pp. 1399-1408
-
-
Pollack, I.F.1
Albright, A.L.2
Adelson, P.D.3
-
12
-
-
0028913470
-
Overdrainage and shunt technology: A critical comparison of programmable, hydrostatic and variable resistance valves and flow-reducing devices
-
Aschoff A, Kremer P, Benesch C, Fruh K, Klank A, Kunze S: Overdrainage and shunt technology: a critical comparison of programmable, hydrostatic and variable resistance valves and flow-reducing devices. Childs Nerv Syst 1995; 11: 193-202.
-
(1995)
Childs Nerv Syst
, vol.11
, pp. 193-202
-
-
Aschoff, A.1
Kremer, P.2
Benesch, C.3
Fruh, K.4
Klank, A.5
Kunze, S.6
-
13
-
-
0026329055
-
Testing the hydrocephalus shunt valve: Long-term bench test results of various new and explanted valves. The need for model for testing valves under physiological conditions
-
Trost HA, Heissler HE, Claussen G, Gaab MR: Testing the hydrocephalus shunt valve: long-term bench test results of various new and explanted valves. The need for model for testing valves under physiological conditions. Eur J Pediatr Surg 1991; 1(suppl 1):38-40.
-
(1991)
Eur J Pediatr Surg
, vol.1
, Issue.SUPPL. 1
, pp. 38-40
-
-
Trost, H.A.1
Heissler, H.E.2
Claussen, G.3
Gaab, M.R.4
-
14
-
-
26944442807
-
A multicenter prospective cohort study of the Strata valve for the management of hydrocephalus in pediatric patients
-
Kestle J, Walker M: A multicenter prospective cohort study of the Strata valve for the management of hydrocephalus in pediatric patients. J Neurosurg 2005; 102(suppl 2):141-145.
-
(2005)
J Neurosurg
, vol.102
, Issue.SUPPL. 2
, pp. 141-145
-
-
Kestle, J.1
Walker, M.2
-
15
-
-
0027533060
-
Functional obstruction of an antisiphon device by raised tissue capsule pressure
-
Drake JM, da Silva MC, Rutka JT: Functional obstruction of an antisiphon device by raised tissue capsule pressure. Neurosurgery 1993; 32: 137-139.
-
(1993)
Neurosurgery
, vol.32
, pp. 137-139
-
-
Drake, J.M.1
Da Silva, M.C.2
Rutka, J.T.3
-
16
-
-
0025034338
-
Clinical experience with a pressure-adjustable valve SOPHY in the management of hydrocephalus
-
Lumenta CB, Roosen N, Dietrich U: Clinical experience with a pressure-adjustable valve SOPHY in the management of hydrocephalus. Childs Nerv Syst 1990; 6: 270-274.
-
(1990)
Childs Nerv Syst
, vol.6
, pp. 270-274
-
-
Lumenta, C.B.1
Roosen, N.2
Dietrich, U.3
-
17
-
-
0028805161
-
Cerebrospinal fluid shunt failure: Late is different from early
-
Piatt JH Jr: Cerebrospinal fluid shunt failure: late is different from early. Pediatr Neurosurg 1995; 23: 129-133.
-
(1995)
Pediatr Neurosurg
, vol.23
, pp. 129-133
-
-
Piatt Jr., J.H.1
-
18
-
-
0024840310
-
Quantification of cerebrospinal fluid shunt flow rates: Assessment of the programmable pressure valve
-
Matsumae M, Sato O, Itoh K, Fukuda T, Suzuki Y: Quantification of cerebrospinal fluid shunt flow rates: assessment of the programmable pressure valve. Childs Nerv Syst 1989; 5: 356-360.
-
(1989)
Childs Nerv Syst
, vol.5
, pp. 356-360
-
-
Matsumae, M.1
Sato, O.2
Itoh, K.3
Fukuda, T.4
Suzuki, Y.5
-
19
-
-
0018176654
-
Overdrainage phenomena in shunt treated hydrocephalus
-
Faulhauer K, Schmitz P: Overdrainage phenomena in shunt treated hydrocephalus. Acta Neurochir 1978; 45: 89-101.
-
(1978)
Acta Neurochir
, vol.45
, pp. 89-101
-
-
Faulhauer, K.1
Schmitz, P.2
-
20
-
-
0025959335
-
Hydrocephalus: Overdrainage by ventricular shunts: A review and recommendations
-
Pudenz RH, Foltz EL: Hydrocephalus: overdrainage by ventricular shunts: a review and recommendations. Surg Neurol 1991; 35: 200-212.
-
(1991)
Surg Neurol
, vol.35
, pp. 200-212
-
-
Pudenz, R.H.1
Foltz, E.L.2
-
21
-
-
0025779696
-
Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions
-
Kamiryo T, Fujii Y, Kusaka M, Kashiwagi S, Ito H: Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions. Childs Nerv Syst 1991; 7: 233-234.
-
(1991)
Childs Nerv Syst
, vol.7
, pp. 233-234
-
-
Kamiryo, T.1
Fujii, Y.2
Kusaka, M.3
Kashiwagi, S.4
Ito, H.5
|