메뉴 건너뛰기




Volumn 98, Issue 3, 2003, Pages 471-476

Clinical experience with the use of a shunt with an adjustable valve in children with hydrocephalus

Author keywords

Adjustable valve; Cerebrospinal fluid shunt; Children; Hydrocephalus

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BRAIN HEMORRHAGE; BRAIN TUMOR; CEREBROSPINAL FLUID SHUNTING; CHILD; HUMAN; HYDROCEPHALUS; IMPLANTATION; INFANT; MAJOR CLINICAL STUDY; MENINGOMYELOCELE; NEUROSURGERY; PRESSURE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SHUNT INFECTION; SURGICAL EQUIPMENT; TREATMENT OUTCOME; VALVE;

EID: 0037373558     PISSN: 00223085     EISSN: None     Source Type: Journal    
DOI: 10.3171/jns.2003.98.3.0471     Document Type: Article
Times cited : (53)

References (30)
  • 1
    • 0028913470 scopus 로고
    • Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices
    • Aschoff A, Kremer P, Benesch C, et al: Overdrainage and shunt technology. A critical comparison of programmable, hydrostatic and variable-resistance valves and flow-reducing devices. Childs Nerv Syst 11:193-202, 1995
    • (1995) Childs Nerv Syst , vol.11 , pp. 193-202
    • Aschoff, A.1    Kremer, P.2    Benesch, C.3
  • 2
    • 0028357712 scopus 로고
    • The use of the Codman-Medos Programmable Hakim valve in the management of patients with hydrocephalus: Illustrative cases
    • Black PM, Hakim R, Bailey NO: The use of the Codman-Medos Programmable Hakim valve in the management of patients with hydrocephalus: illustrative cases. Neurosurgery 34:1110-1113, 1994
    • (1994) Neurosurgery , vol.34 , pp. 1110-1113
    • Black, P.M.1    Hakim, R.2    Bailey, N.O.3
  • 4
    • 0031951739 scopus 로고    scopus 로고
    • Posture-related overdrainage: Comparison of the performance of 10 hydrocephalus shunts in vitro
    • Czosnyka Z, Czosnyka M, Richards HK, et al: Posture-related overdrainage: comparison of the performance of 10 hydrocephalus shunts in vitro. Neurosurgery 42:327-334, 1998
    • (1998) Neurosurgery , vol.42 , pp. 327-334
    • Czosnyka, Z.1    Czosnyka, M.2    Richards, H.K.3
  • 5
    • 7344257733 scopus 로고    scopus 로고
    • Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus
    • Drake JM, Kestle IR, Milner R, et al: Randomized trial of cerebrospinal fluid shunt valve design in pediatric hydrocephalus. Neurosurgery 43:294-305, 1998
    • (1998) Neurosurgery , vol.43 , pp. 294-305
    • Drake, J.M.1    Kestle, I.R.2    Milner, R.3
  • 6
    • 0028308937 scopus 로고
    • Computer modeling of siphoning for CSF shunt design evaluation
    • Drake JM, Tenti G, Sivalsganathan S: Computer modeling of siphoning for CSF shunt design evaluation. Pediatr Neurosurg 21: 6-15, 1994
    • (1994) Pediatr Neurosurg , vol.21 , pp. 6-15
    • Drake, J.M.1    Tenti, G.2    Sivalsganathan, S.3
  • 7
    • 0025810426 scopus 로고
    • Management with a programmable pressure valve of subdural hematomas caused by a ventriculoperitoneal shunt: Case report
    • Kamano S, Nakano Y, Imanishi T, et al: Management with a programmable pressure valve of subdural hematomas caused by a ventriculoperitoneal shunt: case report. Surg Neurol 35:381-383, 1991
    • (1991) Surg Neurol , vol.35 , pp. 381-383
    • Kamano, S.1    Nakano, Y.2    Imanishi, T.3
  • 8
    • 0025779696 scopus 로고
    • Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions
    • Kamiryo T, Fujii Y, Kusaka M, et al: Intracranial pressure monitoring using a programmable pressure valve and a telemetric intracranial pressure sensor in a case of slit ventricle syndrome after multiple shunt revisions. Childs Nerv Syst 7:233-234, 1991
    • (1991) Childs Nerv Syst , vol.7 , pp. 233-234
    • Kamiryo, T.1    Fujii, Y.2    Kusaka, M.3
  • 9
    • 17744397290 scopus 로고    scopus 로고
    • Long-term follow-up data from the Shunt Design Trial
    • Kestle J, Drake J, Milner R, et al: Long-term follow-up data from the Shunt Design Trial. Pediatr Neurosurg 33:230-236, 2000
    • (2000) Pediatr Neurosurg , vol.33 , pp. 230-236
    • Kestle, J.1    Drake, J.2    Milner, R.3
  • 10
    • 0025034338 scopus 로고
    • Clinical experience with a pressure-adjustable valve SOPHY in the management of hydrocephalus
    • Lumenta CB, Roosen N, Dietrich U: Clinical experience with a pressure-adjustable valve SOPHY in the management of hydrocephalus. Childs Nerv Syst 6:270-274, 1990
    • (1990) Childs Nerv Syst , vol.6 , pp. 270-274
    • Lumenta, C.B.1    Roosen, N.2    Dietrich, U.3
  • 11
    • 85038519462 scopus 로고    scopus 로고
    • Experience of the programmable Codman Medos valve in paediatric hydrocephalus: A 7-year retrospective study
    • Abstract
    • Lundkvist K, Eriksson E, Olsen L: Experience of the programmable Codman Medos valve in paediatric hydrocephalus: a 7-year retrospective study. Eur J Pediatr Surg 11 (Suppl 1):S60, 2001 (Abstract)
    • (2001) Eur J Pediatr Surg , vol.11 , Issue.SUPPL. 1
    • Lundkvist, K.1    Eriksson, E.2    Olsen, L.3
  • 12
    • 0036281845 scopus 로고    scopus 로고
    • Cerebrospinal fluid shunt survival and etiology of failures: A seven-year institutional experience
    • McGirt MJ, Leveque JC, Wellons JC III, et al: Cerebrospinal fluid shunt survival and etiology of failures: a seven-year institutional experience. Pediatr Neurosurg 36:248-255, 2002
    • (2002) Pediatr Neurosurg , vol.36 , pp. 248-255
    • McGirt, M.J.1    Leveque, J.C.2    Wellons J.C. III3
  • 13
    • 0035093703 scopus 로고    scopus 로고
    • Pressure changes observed in Codman-Medos programmable valves following magnetic exposure and filliping
    • Miwa K, Kondo H, Sakai N: Pressure changes observed in Codman-Medos programmable valves following magnetic exposure and filliping. Childs Nerv Syst 17:150-153, 2001
    • (2001) Childs Nerv Syst , vol.17 , pp. 150-153
    • Miwa, K.1    Kondo, H.2    Sakai, N.3
  • 14
    • 0030920286 scopus 로고    scopus 로고
    • A new ventriculoperitoneal shunt with a telemetric intracranial pressure sensor: Clinical experience in 94 patients with hydrocephalus
    • Miyake H, Ohta T, Kajimoto Y, et al: A new ventriculoperitoneal shunt with a telemetric intracranial pressure sensor: clinical experience in 94 patients with hydrocephalus. Neurosurgery 40: 931-935, 1997
    • (1997) Neurosurgery , vol.40 , pp. 931-935
    • Miyake, H.1    Ohta, T.2    Kajimoto, Y.3
  • 15
    • 0027179605 scopus 로고
    • A search for determinants of cerebrospinal fluid shunt survival: Retrospective analysis of a 14-year institutional experience
    • Piatt JH Jr, Carlson CV: A search for determinants of cerebrospinal fluid shunt survival: retrospective analysis of a 14-year institutional experience. Pediatr Neurosurg 19:233-242, 1993
    • (1993) Pediatr Neurosurg , vol.19 , pp. 233-242
    • Piatt J.H., Jr.1    Carlson, C.V.2
  • 16
    • 0032764025 scopus 로고    scopus 로고
    • A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus
    • Hakim-Medos Investigator Group
    • Pollack IF, Albright AL, Adelson PD: A randomized, controlled study of a programmable shunt valve versus a conventional valve for patients with hydrocephalus. Hakim-Medos Investigator Group. Neurosurgery 45:1399-1411, 1999
    • (1999) Neurosurgery , vol.45 , pp. 1399-1411
    • Pollack, I.F.1    Albright, A.L.2    Adelson, P.D.3
  • 17
    • 0029008223 scopus 로고
    • Clinical experience with a new pressure-adjustable shunt valve
    • Reinprecht A, Czech T, Dietrich W: Clinical experience with a new pressure-adjustable shunt valve. Acta Neurochir 134: 119-124, 1995
    • (1995) Acta Neurochir , vol.134 , pp. 119-124
    • Reinprecht, A.1    Czech, T.2    Dietrich, W.3
  • 18
    • 0035198430 scopus 로고    scopus 로고
    • Posthemorrhagic hydrocephalus in preterm infants: Long-term follow-up and shunt-related complications
    • Reinprecht A, Dietrich W, Berger A, et al: Posthemorrhagic hydrocephalus in preterm infants: long-term follow-up and shunt-related complications. Childs Nerv Syst 17:663-669, 2001
    • (2001) Childs Nerv Syst , vol.17 , pp. 663-669
    • Reinprecht, A.1    Dietrich, W.2    Berger, A.3
  • 19
    • 0031457982 scopus 로고    scopus 로고
    • The Medos Hakim programmable valve in the treatment of pediatric hydrocephalus
    • Reinprecht A, Dietrich W, Bertalanffy A, et al: The Medos Hakim programmable valve in the treatment of pediatric hydrocephalus. Childs Nerv Syst 13:588-594, 1997
    • (1997) Childs Nerv Syst , vol.13 , pp. 588-594
    • Reinprecht, A.1    Dietrich, W.2    Bertalanffy, A.3
  • 20
    • 0031785844 scopus 로고    scopus 로고
    • Four-year experience with the routine use of the programmable Hakim valve in the management of children with hydrocephalus
    • Rohde V, Mayfrank L, Ramakers VT, et al: Four-year experience with the routine use of the programmable Hakim valve in the management of children with hydrocephalus. Acta Neurochir 140:1127-1134, 1998
    • (1998) Acta Neurochir , vol.140 , pp. 1127-1134
    • Rohde, V.1    Mayfrank, L.2    Ramakers, V.T.3
  • 22
    • 0025501575 scopus 로고
    • Die therapie des normaldruckhydrocephalus mit dem transcutan magnetisch verstellbaren ventil
    • Schmitt J, Spring A: Die Therapie des Normaldruckhydrocephalus mit dem transcutan magnetisch verstellbaren ventil. Neurochirurgia 33 (Suppl 1):23-26, 1990
    • (1990) Neurochirurgia , vol.33 , Issue.SUPPL. 1 , pp. 23-26
    • Schmitt, J.1    Spring, A.2
  • 23
    • 0036125899 scopus 로고    scopus 로고
    • Electromagnetic field hazards involving adjustable shunt valves in hydrocephalus
    • Schneider T, Knauff U, Nitsch J, et al: Electromagnetic field hazards involving adjustable shunt valves in hydrocephalus. J Neurosurg 96:331-334, 2002
    • (2002) J Neurosurg , vol.96 , pp. 331-334
    • Schneider, T.1    Knauff, U.2    Nitsch, J.3
  • 24
    • 0027316383 scopus 로고
    • Transcutaneous pressure adjustable valve for the treatment of hydrocephalus and arachnoid cysts in adults. Experiences with 75 cases
    • Sindou M, Guyotat-Pelissou I, Chidiac A, et al: Transcutaneous pressure adjustable valve for the treatment of hydrocephalus and arachnoid cysts in adults. Experiences with 75 cases. Acta Neurochir 121:135-139, 1993
    • (1993) Acta Neurochir , vol.121 , pp. 135-139
    • Sindou, M.1    Guyotat-Pelissou, I.2    Chidiac, A.3
  • 26
    • 0026329055 scopus 로고
    • Testing the hydrocephalus shunt valve: Long-term bench test results of various new and explanted valves. The need for model for testing valves under physiological conditions
    • Trost HA, Heissler HE, Claussen G, et al: Testing the hydrocephalus shunt valve: long-term bench test results of various new and explanted valves. The need for model for testing valves under physiological conditions. Eur J Pediatr Surg 1 (Suppl 1):38-40, 1991
    • (1991) Eur J Pediatr Surg , vol.1 , Issue.SUPPL. 1 , pp. 38-40
    • Trost, H.A.1    Heissler, H.E.2    Claussen, G.3
  • 27
    • 0033980922 scopus 로고    scopus 로고
    • Risk factors for repeated cerebrospinal shunt failures in pediatric patients with hydrocephalus
    • Tuli S, Drake J, Lawless J, et al: Risk factors for repeated cerebrospinal shunt failures in pediatric patients with hydrocephalus. J Neurosurg 92:31-38, 2000
    • (2000) J Neurosurg , vol.92 , pp. 31-38
    • Tuli, S.1    Drake, J.2    Lawless, J.3
  • 28
    • 0032699035 scopus 로고    scopus 로고
    • Experience with a programmable valve shunt system
    • Yamashita N, Kamiya K, Yamada K: Experience with a programmable valve shunt system. J Neurosurg 91:26-31, 1999
    • (1999) J Neurosurg , vol.91 , pp. 26-31
    • Yamashita, N.1    Kamiya, K.2    Yamada, K.3
  • 29
    • 0034943362 scopus 로고    scopus 로고
    • Do adjustable shunt valves pressure our budget? A retrospective analysis of 541 implanted Codman Hakim programmable valves
    • Zemack G, Romner B: Do adjustable shunt valves pressure our budget? A retrospective analysis of 541 implanted Codman Hakim programmable valves. Br J Neurosurg 15:221-227, 2001
    • (2001) Br J Neurosurg , vol.15 , pp. 221-227
    • Zemack, G.1    Romner, B.2
  • 30
    • 0034040516 scopus 로고    scopus 로고
    • Seven years of clinical experience with the programmable Codman Hakim valve: A retrospective study of 583 patients
    • Zemack G, Romner B: Seven years of clinical experience with the programmable Codman Hakim valve: a retrospective study of 583 patients. J Neurosurg 92:941-948, 2000
    • (2000) J Neurosurg , vol.92 , pp. 941-948
    • Zemack, G.1    Romner, B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.