메뉴 건너뛰기




Volumn 36, Issue 5, 2010, Pages 756-761

Predictability of ocular spherical aberration after cataract surgery determined using preoperative corneal spherical aberration

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; CALCULATION; CATARACT EXTRACTION; CLINICAL ARTICLE; CORNEA DISEASE; CORNEAL SPHERICAL ABERRATION; FEASIBILITY STUDY; FEMALE; HUMAN; LENS IMPLANTATION; MALE; MATHEMATICAL ANALYSIS; POSTOPERATIVE COMPLICATION; PREDICTION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; REFRACTION ERROR; SYSTEMATIC ERROR;

EID: 77951941507     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2009.11.020     Document Type: Article
Times cited : (6)

References (24)
  • 2
    • 34247529037 scopus 로고    scopus 로고
    • Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values
    • Beiko G.H.H., Haigis W., and Steinmueller A. Distribution of corneal spherical aberration in a comprehensive ophthalmology practice and whether keratometry can predict aberration values. J Cataract Refract Surg 33 (2007) 848-858
    • (2007) J Cataract Refract Surg , vol.33 , pp. 848-858
    • Beiko, G.H.H.1    Haigis, W.2    Steinmueller, A.3
  • 3
    • 59449085428 scopus 로고    scopus 로고
    • Aspheric intraocular lens selection based on corneal wavefront
    • Packer M., Fine I.H., and Hoffman R.S. Aspheric intraocular lens selection based on corneal wavefront. J Refract Surg 25 (2009) 12-20
    • (2009) J Refract Surg , vol.25 , pp. 12-20
    • Packer, M.1    Fine, I.H.2    Hoffman, R.S.3
  • 5
    • 47749138116 scopus 로고    scopus 로고
    • Custom optimization of intraocular lens asphericity
    • Accessed January 20, 2010
    • Koch D.D., and Wang L. Custom optimization of intraocular lens asphericity. Trans Am Ophthalmol Soc 105 (2007) 36-41. http://www.aosonline.org/xactions/2007/1545-6110_v105_p036.pdf Accessed January 20, 2010
    • (2007) Trans Am Ophthalmol Soc , vol.105 , pp. 36-41
    • Koch, D.D.1    Wang, L.2
  • 6
    • 61349154859 scopus 로고    scopus 로고
    • Comparative study of aspheric intraocular lenses with negative spherical aberration or no aberration
    • Denoyer A., Denoyer L., Halfon J., Majzoub S., and Pisella P.-J. Comparative study of aspheric intraocular lenses with negative spherical aberration or no aberration. J Cataract Refract Surg 35 (2009) 496-503
    • (2009) J Cataract Refract Surg , vol.35 , pp. 496-503
    • Denoyer, A.1    Denoyer, L.2    Halfon, J.3    Majzoub, S.4    Pisella, P.-J.5
  • 7
    • 0036581933 scopus 로고    scopus 로고
    • Clinical applications of the OPD-Scan wavefront aberrometer/corneal topographer
    • Buscemi P. Clinical applications of the OPD-Scan wavefront aberrometer/corneal topographer. J Refract Surg 18 (2002) S385-S388
    • (2002) J Refract Surg , vol.18
    • Buscemi, P.1
  • 8
    • 0033782322 scopus 로고    scopus 로고
    • Slit skiascopic-guided ablation using the Nidek laser
    • MacRae S., and Fujieda M. Slit skiascopic-guided ablation using the Nidek laser. J Refract Surg 16 (2000) S576-S580
    • (2000) J Refract Surg , vol.16
    • MacRae, S.1    Fujieda, M.2
  • 9
    • 19344374372 scopus 로고    scopus 로고
    • Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study
    • errata, 1857
    • Bellucci R., Scialdone A., Buratto L., Morselli S., Chierego C., Criscuoli A., Moretti G., and Piers P. Visual acuity and contrast sensitivity comparison between Tecnis and AcrySof SA60AT intraocular lenses: a multicenter randomized study. J Cataract Refract Surg 31 (2005) 712-717 errata, 1857
    • (2005) J Cataract Refract Surg , vol.31 , pp. 712-717
    • Bellucci, R.1    Scialdone, A.2    Buratto, L.3    Morselli, S.4    Chierego, C.5    Criscuoli, A.6    Moretti, G.7    Piers, P.8
  • 10
    • 34548713585 scopus 로고    scopus 로고
    • Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes
    • Caporossi A., Martone G., Casprini F., and Rapisarda L. Prospective randomized study of clinical performance of 3 aspheric and 2 spherical intraocular lenses in 250 eyes. J Refract Surg 23 (2007) 639-648
    • (2007) J Refract Surg , vol.23 , pp. 639-648
    • Caporossi, A.1    Martone, G.2    Casprini, F.3    Rapisarda, L.4
  • 11
    • 65349195057 scopus 로고    scopus 로고
    • Objective and subjective outcomes in comparing three different aspheric intraocular lens implants with their spherical counterparts
    • Cuthbertson F.M., Dhingra S., and Benjamin L. Objective and subjective outcomes in comparing three different aspheric intraocular lens implants with their spherical counterparts. Eye 23 (2009) 877-883
    • (2009) Eye , vol.23 , pp. 877-883
    • Cuthbertson, F.M.1    Dhingra, S.2    Benjamin, L.3
  • 12
    • 33846571317 scopus 로고    scopus 로고
    • Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision
    • Denoyer A., Le Lez M.-L., Majzoub S., and Pisella P.-J. Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation: effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision. J Cataract Refract Surg 33 (2007) 210-216
    • (2007) J Cataract Refract Surg , vol.33 , pp. 210-216
    • Denoyer, A.1    Le Lez, M.-L.2    Majzoub, S.3    Pisella, P.-J.4
  • 13
    • 0037387972 scopus 로고    scopus 로고
    • Impact of a modified optic design on visual function: clinical comparative study
    • Mester U., Dillinger P., and Anterist N. Impact of a modified optic design on visual function: clinical comparative study. J Cataract Refract Surg 29 (2003) 652-660
    • (2003) J Cataract Refract Surg , vol.29 , pp. 652-660
    • Mester, U.1    Dillinger, P.2    Anterist, N.3
  • 14
    • 33947595775 scopus 로고    scopus 로고
    • Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens; prospective randomized masked clinical trial
    • Pandita D., Raj S.M., Vasavada V.A., Vasavada V.A., Kazi N.S., and Vasavada A.R. Contrast sensitivity and glare disability after implantation of AcrySof IQ Natural aspherical intraocular lens; prospective randomized masked clinical trial. J Cataract Refract Surg 33 (2007) 603-610
    • (2007) J Cataract Refract Surg , vol.33 , pp. 603-610
    • Pandita, D.1    Raj, S.M.2    Vasavada, V.A.3    Vasavada, V.A.4    Kazi, N.S.5    Vasavada, A.R.6
  • 15
    • 33750084170 scopus 로고    scopus 로고
    • Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study
    • Rocha K.M., Soriano E.S., Chalita M.R., Yamada A.C., Bottós K., Bottós J., Morimoto L., and Nosé W. Wavefront analysis and contrast sensitivity of aspheric and spherical intraocular lenses: a randomized prospective study. Am J Ophthalmol 142 (2006) 750-756
    • (2006) Am J Ophthalmol , vol.142 , pp. 750-756
    • Rocha, K.M.1    Soriano, E.S.2    Chalita, M.R.3    Yamada, A.C.4    Bottós, K.5    Bottós, J.6    Morimoto, L.7    Nosé, W.8
  • 16
    • 57649164703 scopus 로고    scopus 로고
    • Comparison of visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs spherical acrylic lenses
    • Sandoval H.P., Fernández de Castro L.E., Vroman D.T., and Solomon K.D. Comparison of visual outcomes, photopic contrast sensitivity, wavefront analysis, and patient satisfaction following cataract extraction and IOL implantation: aspheric vs spherical acrylic lenses. Eye 22 (2008) 1469-1475
    • (2008) Eye , vol.22 , pp. 1469-1475
    • Sandoval, H.P.1    Fernández de Castro, L.E.2    Vroman, D.T.3    Solomon, K.D.4
  • 17
    • 43049138747 scopus 로고    scopus 로고
    • Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study
    • Tzelikis P.F., Akaishi L., Trindade F.C., and Boteon J.E. Spherical aberration and contrast sensitivity in eyes implanted with aspheric and spherical intraocular lenses: a comparative study. Am J Ophthalmol 145 (2008) 827-833
    • (2008) Am J Ophthalmol , vol.145 , pp. 827-833
    • Tzelikis, P.F.1    Akaishi, L.2    Trindade, F.C.3    Boteon, J.E.4
  • 18
    • 69249205437 scopus 로고    scopus 로고
    • Effect of intraocular lens asphericity on quality of vision after cataract removal; an intraindividual comparison
    • Kohnen T., Klaproth O.K., and Bühren J. Effect of intraocular lens asphericity on quality of vision after cataract removal; an intraindividual comparison. Ophthalmology 116 (2009) 1697-1706
    • (2009) Ophthalmology , vol.116 , pp. 1697-1706
    • Kohnen, T.1    Klaproth, O.K.2    Bühren, J.3
  • 19
  • 20
    • 45249108838 scopus 로고    scopus 로고
    • Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses
    • Awwad S.T., Warmerdam D., Bowman R.W., Dwarakanathan S., Cavanagh H.D., and McCulley J.P. Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses. J Refract Surg 24 (2008) 619-625
    • (2008) J Refract Surg , vol.24 , pp. 619-625
    • Awwad, S.T.1    Warmerdam, D.2    Bowman, R.W.3    Dwarakanathan, S.4    Cavanagh, H.D.5    McCulley, J.P.6
  • 21
    • 33644501101 scopus 로고    scopus 로고
    • Monochromatic aberrations in eyes with different intraocular lens optic designs
    • Padmanabhan P., Rao S.K., Jayasree R., Chowdhry M., and Roy J. Monochromatic aberrations in eyes with different intraocular lens optic designs. J Refract Surg 22 (2006) 172-177
    • (2006) J Refract Surg , vol.22 , pp. 172-177
    • Padmanabhan, P.1    Rao, S.K.2    Jayasree, R.3    Chowdhry, M.4    Roy, J.5
  • 22
    • 9444291402 scopus 로고    scopus 로고
    • Corneal aberrations before and after small-incision cataract surgery
    • Accessed January 20, 2010
    • Guirao A., Tejedor J., and Artal P. Corneal aberrations before and after small-incision cataract surgery. Invest Ophthalmol Vis Sci 45 (2004) 4312-4319. http://www.iovs.org/cgi/reprint/45/12/4312 Accessed January 20, 2010
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 4312-4319
    • Guirao, A.1    Tejedor, J.2    Artal, P.3
  • 23
    • 33846644402 scopus 로고    scopus 로고
    • Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses
    • Marcos S., Rosales P., Llorente L., and Jiménez-Alfaro I. Change in corneal aberrations after cataract surgery with 2 types of aspherical intraocular lenses. J Cataract Refract Surg 33 (2007) 217-226
    • (2007) J Cataract Refract Surg , vol.33 , pp. 217-226
    • Marcos, S.1    Rosales, P.2    Llorente, L.3    Jiménez-Alfaro, I.4
  • 24
    • 61349138909 scopus 로고    scopus 로고
    • Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes
    • Mester U., Sauer T., and Kaymak H. Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes. J Cataract Refract Surg 35 (2009) 485-490
    • (2009) J Cataract Refract Surg , vol.35 , pp. 485-490
    • Mester, U.1    Sauer, T.2    Kaymak, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.