메뉴 건너뛰기




Volumn 79, Issue 1, 2010, Pages 147-151

Enzymatic flow injection method for rapid determination of choline in urine with electrochemiluminescence detection

Author keywords

Choline; Electrochemiluminescence; Enzyme reactor; Flow injection; Human urine

Indexed keywords

ABSOLUTE DETECTION LIMITS; AMINOPROPYL; ANALYTICAL RESULTS; CHOLINE OXIDASE; CONCENTRATION OF; CONTROLLED PORE GLASS; DETECTION LIMITS; DOWN STREAM; ELECTROCHEMICAL DETECTION SYSTEMS; ELECTROCHEMILUMINESCENCE; ELECTROCHEMILUMINESCENCE DETECTION; ENZYME REACTORS; FLOW INJECTION; FLOW INJECTION ANALYSIS SYSTEMS; FLOW INJECTION METHOD; HIGH SENSITIVITY; HUMAN URINE; IMMOBILIZED ENZYME REACTORS; MICROCOLUMNS; OPTIMIZED CONDITIONS; PRODUCTION OF HYDROGEN; RAPID DETERMINATION;

EID: 77951878339     PISSN: 15675394     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bioelechem.2009.12.005     Document Type: Article
Times cited : (18)

References (25)
  • 1
    • 34547962614 scopus 로고    scopus 로고
    • Choline: dietary requirements and role in brain development
    • Sanders L.M., and Zeisel S.H. Choline: dietary requirements and role in brain development. Nutr. Today 42 (2007) 181-186
    • (2007) Nutr. Today , vol.42 , pp. 181-186
    • Sanders, L.M.1    Zeisel, S.H.2
  • 4
    • 33749012286 scopus 로고    scopus 로고
    • Application of metabonomics in a compound ranking study in early drug development revealing drug-induced excretion of choline into urine
    • Dieterle F., Schlotterbeck G., Ross A., Niederhauser U., and Senn H. Application of metabonomics in a compound ranking study in early drug development revealing drug-induced excretion of choline into urine. Chem. Res. Toxicol. 19 (2006) 1175-1181
    • (2006) Chem. Res. Toxicol. , vol.19 , pp. 1175-1181
    • Dieterle, F.1    Schlotterbeck, G.2    Ross, A.3    Niederhauser, U.4    Senn, H.5
  • 6
    • 4644344459 scopus 로고    scopus 로고
    • Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode
    • Yang M., Yang Y., Yang Y., Shen G., and Yu R. Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode. Anal. Biochem. 334 (2004) 127-134
    • (2004) Anal. Biochem. , vol.334 , pp. 127-134
    • Yang, M.1    Yang, Y.2    Yang, Y.3    Shen, G.4    Yu, R.5
  • 7
    • 33646228832 scopus 로고    scopus 로고
    • Amperometric aqueous sol-gel biosensor for low-potential stable choline detection at multi-wall carbon nanotube modified platinum electrode
    • Song Z., Huang J.-D., Wu B.-Y., Shi H.-B., Anzai J.-I., and Chen Q. Amperometric aqueous sol-gel biosensor for low-potential stable choline detection at multi-wall carbon nanotube modified platinum electrode. Sens. Actuators B 115 (2006) 626-633
    • (2006) Sens. Actuators B , vol.115 , pp. 626-633
    • Song, Z.1    Huang, J.-D.2    Wu, B.-Y.3    Shi, H.-B.4    Anzai, J.-I.5    Chen, Q.6
  • 8
    • 27644572660 scopus 로고    scopus 로고
    • Amperometric biosensor for choline based on layer-by-layer assembled functionalized carbon nanotube and polyaniline multilayer film
    • Qu F., Yang M., Jiang J., Shen G., and Yu R. Amperometric biosensor for choline based on layer-by-layer assembled functionalized carbon nanotube and polyaniline multilayer film. Anal. Biochem. 344 (2005) 108-114
    • (2005) Anal. Biochem. , vol.344 , pp. 108-114
    • Qu, F.1    Yang, M.2    Jiang, J.3    Shen, G.4    Yu, R.5
  • 9
    • 13444309426 scopus 로고    scopus 로고
    • Microbiosensor for acetylcholine and choline based on electropolymerization/sol-gel derived composite membrane
    • Yang M., Yang Y., Yang Y., Shen G., and Yu R. Microbiosensor for acetylcholine and choline based on electropolymerization/sol-gel derived composite membrane. Anal. Chim. Acta 530 (2005) 205-211
    • (2005) Anal. Chim. Acta , vol.530 , pp. 205-211
    • Yang, M.1    Yang, Y.2    Yang, Y.3    Shen, G.4    Yu, R.5
  • 10
    • 5644228862 scopus 로고    scopus 로고
    • Choline determination based on the intrinsic and the extrinsic (chemically modified) fluorescence of choline oxidase
    • Galbán J., Sánchez-Monreal O., Andreu Y., de Marcos S., and Castillo J.R. Choline determination based on the intrinsic and the extrinsic (chemically modified) fluorescence of choline oxidase. Anal. Biochem. 334 (2004) 207-215
    • (2004) Anal. Biochem. , vol.334 , pp. 207-215
    • Galbán, J.1    Sánchez-Monreal, O.2    Andreu, Y.3    de Marcos, S.4    Castillo, J.R.5
  • 13
    • 0034730889 scopus 로고    scopus 로고
    • Separation methods used in the determination of choline and acetylcholine
    • Tsai T.-H. Separation methods used in the determination of choline and acetylcholine. J. Chromatogr. B 747 (2000) 111-122
    • (2000) J. Chromatogr. B , vol.747 , pp. 111-122
    • Tsai, T.-H.1
  • 14
    • 0032502869 scopus 로고    scopus 로고
    • Disposable, enzymatically modified printed film carbon electrodes for use in the high-performance liquid chromatographic -electrochemical detection of glucose or hydrogen peroxide from immobilized enzyme reactors
    • Osborne P.G., and Yamamoto K. Disposable, enzymatically modified printed film carbon electrodes for use in the high-performance liquid chromatographic -electrochemical detection of glucose or hydrogen peroxide from immobilized enzyme reactors. J. Chromatogr. B 707 (1998) 3-8
    • (1998) J. Chromatogr. B , vol.707 , pp. 3-8
    • Osborne, P.G.1    Yamamoto, K.2
  • 15
    • 34250651709 scopus 로고    scopus 로고
    • Flow injection determination of choline in milk hydrolysates by an immobilized enzyme reactor coupled to a selective hydrogen peroxide amperometric sensor
    • Pati S., Quinto M., and Palmisano F. Flow injection determination of choline in milk hydrolysates by an immobilized enzyme reactor coupled to a selective hydrogen peroxide amperometric sensor. Anal. Chim. Acta 594 (2007) 234-239
    • (2007) Anal. Chim. Acta , vol.594 , pp. 234-239
    • Pati, S.1    Quinto, M.2    Palmisano, F.3
  • 16
    • 0037173517 scopus 로고    scopus 로고
    • Internal standard method for the measurement of choline and acetylcholine by capillary electrophoresis with electrochemical detection
    • Wise D.D., Barkhimer T.V., Brault P.-A., Kirchhoff J.R., Messer Jr. W.S., and Hudson R.A. Internal standard method for the measurement of choline and acetylcholine by capillary electrophoresis with electrochemical detection. J. Chromatogr. B 775 (2002) 49-56
    • (2002) J. Chromatogr. B , vol.775 , pp. 49-56
    • Wise, D.D.1    Barkhimer, T.V.2    Brault, P.-A.3    Kirchhoff, J.R.4    Messer Jr., W.S.5    Hudson, R.A.6
  • 18
    • 0032967364 scopus 로고    scopus 로고
    • Luminol electrochemiluminescence-based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples
    • Marquette C.A., and Blum L.J. Luminol electrochemiluminescence-based fibre optic biosensors for flow injection analysis of glucose and lactate in natural samples. Anal. Chim. Acta 381 (1999) 1-10
    • (1999) Anal. Chim. Acta , vol.381 , pp. 1-10
    • Marquette, C.A.1    Blum, L.J.2
  • 19
    • 0035871657 scopus 로고    scopus 로고
    • Screen-printed electrodes as disposable or reusable optical devices for luminol electrochemiluminescence
    • Leca B.D., Verdier A.M., and Blum L.J. Screen-printed electrodes as disposable or reusable optical devices for luminol electrochemiluminescence. Sens. Actuators B 74 (2001) 190-193
    • (2001) Sens. Actuators B , vol.74 , pp. 190-193
    • Leca, B.D.1    Verdier, A.M.2    Blum, L.J.3
  • 20
    • 0242583647 scopus 로고    scopus 로고
    • Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate
    • Marquette C.A., Degiuli A., and Blum L.J. Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate. Biosens. Bioelectron. 19 (2003) 433-439
    • (2003) Biosens. Bioelectron. , vol.19 , pp. 433-439
    • Marquette, C.A.1    Degiuli, A.2    Blum, L.J.3
  • 21
    • 33745495994 scopus 로고    scopus 로고
    • Microscale electrochemiluminescence analysis with an ultrasonic vibration electrode
    • Hiroi T., Inui A., Jin J., and Takeuchi T. Microscale electrochemiluminescence analysis with an ultrasonic vibration electrode. Microchim. Acta 158 (2006) 269-274
    • (2006) Microchim. Acta , vol.158 , pp. 269-274
    • Hiroi, T.1    Inui, A.2    Jin, J.3    Takeuchi, T.4
  • 22
    • 0025239799 scopus 로고
    • Sensitive biosensor for choline and acetylcholine involving fast immobilization of a bienzyme system on a disposable membrane
    • Morelis R.M., and Coulet P.R. Sensitive biosensor for choline and acetylcholine involving fast immobilization of a bienzyme system on a disposable membrane. Anal. Chim. Acta 231 (1990) 27-32
    • (1990) Anal. Chim. Acta , vol.231 , pp. 27-32
    • Morelis, R.M.1    Coulet, P.R.2
  • 24
    • 43049148964 scopus 로고    scopus 로고
    • An electrochemiluminescent biosensor for vitamin C based on inhibition of luminol electrochemiluminescence on graphite/poly(methylmethacrylate) composite electrode
    • Daia H., Wua X., Wanga Y., Zhoua W., and Chen G. An electrochemiluminescent biosensor for vitamin C based on inhibition of luminol electrochemiluminescence on graphite/poly(methylmethacrylate) composite electrode. Electrochim. Acta 53 (2008) 5113-5117
    • (2008) Electrochim. Acta , vol.53 , pp. 5113-5117
    • Daia, H.1    Wua, X.2    Wanga, Y.3    Zhoua, W.4    Chen, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.