메뉴 건너뛰기




Volumn 115, Issue 2, 2006, Pages 626-633

Amperometric aqueous sol-gel biosensor for low-potential stable choline detection at multi-wall carbon nanotube modified platinum electrode

Author keywords

Choline; Electrocatalysis; Hydrogen peroxide; Multi wall carbon nanotubes; Sol gel

Indexed keywords

CARBON NANOTUBES; CYCLIC VOLTAMMETRY; ELECTROCHEMICAL ELECTRODES; ENZYME IMMOBILIZATION; HYDROGEN PEROXIDE; OXIDATION; PLATINUM; SILICATE MINERALS; SOL-GELS;

EID: 33646228832     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2005.10.030     Document Type: Article
Times cited : (91)

References (39)
  • 1
    • 0024598955 scopus 로고
    • Choline increases acetylcholine release and protects against the stimulation induced decrease in phosphatide levels within membranes of rat corpus striatum
    • Ulus I.H., Wurtman R.J., Mauron C., and Blusztajn J.K. Choline increases acetylcholine release and protects against the stimulation induced decrease in phosphatide levels within membranes of rat corpus striatum. Brain Res. 484 (1989) 217-222
    • (1989) Brain Res. , vol.484 , pp. 217-222
    • Ulus, I.H.1    Wurtman, R.J.2    Mauron, C.3    Blusztajn, J.K.4
  • 2
    • 0038333251 scopus 로고    scopus 로고
    • Concentrations of choline-containing compounds and betaine in common foods
    • Zeisel S.H., Mar M.H., Howe J.C., and Holden J.M. Concentrations of choline-containing compounds and betaine in common foods. J. Nutr. 133 (2003) 1302-1307
    • (2003) J. Nutr. , vol.133 , pp. 1302-1307
    • Zeisel, S.H.1    Mar, M.H.2    Howe, J.C.3    Holden, J.M.4
  • 3
    • 0037307164 scopus 로고    scopus 로고
    • Determination of choline, betaine, and dimethylglycine in plasma by a high-throughput method based on normal-phase chromatography-tandem mass spectrometry
    • Holm P.I., Ueland P.M., Kvalheim G., and Lien E.A. Determination of choline, betaine, and dimethylglycine in plasma by a high-throughput method based on normal-phase chromatography-tandem mass spectrometry. Clin. Chem. 49 (2003) 286-294
    • (2003) Clin. Chem. , vol.49 , pp. 286-294
    • Holm, P.I.1    Ueland, P.M.2    Kvalheim, G.3    Lien, E.A.4
  • 4
    • 0025803731 scopus 로고
    • A postmortem study of brain nicotinic receptors in parkinsons and alzheimers
    • Rinne J.O., Myllykyla T., Lonnberg P., and Marjamaki P. A postmortem study of brain nicotinic receptors in parkinsons and alzheimers. Brain Res. 547 (1991) 167-170
    • (1991) Brain Res. , vol.547 , pp. 167-170
    • Rinne, J.O.1    Myllykyla, T.2    Lonnberg, P.3    Marjamaki, P.4
  • 5
    • 0037145719 scopus 로고    scopus 로고
    • Impairment of cholinergic neurotransmission in adult and aged transgenic Tg2576 mouse brain expressing the Swedish mutation of human b-amyloid precursor protein
    • Jenny A., Ashok K., and Reinhard S. Impairment of cholinergic neurotransmission in adult and aged transgenic Tg2576 mouse brain expressing the Swedish mutation of human b-amyloid precursor protein. Brain Res. 953 (2002) 17-30
    • (2002) Brain Res. , vol.953 , pp. 17-30
    • Jenny, A.1    Ashok, K.2    Reinhard, S.3
  • 6
    • 0242383891 scopus 로고    scopus 로고
    • Alterations in cholinergic and non-cholinergic neurotransmitter receptor densities in transgenic Tg2576 mouse brain with β-amyloid plaque pathology
    • Margrit K., Jenny A., Ashok K., Dietlind S., Osama S., Jörg S., Matthias S., and Reinhard S. Alterations in cholinergic and non-cholinergic neurotransmitter receptor densities in transgenic Tg2576 mouse brain with β-amyloid plaque pathology. Int. J. Dev. Neurosci. 21 (2003) 357-369
    • (2003) Int. J. Dev. Neurosci. , vol.21 , pp. 357-369
    • Margrit, K.1    Jenny, A.2    Ashok, K.3    Dietlind, S.4    Osama, S.5    Jörg, S.6    Matthias, S.7    Reinhard, S.8
  • 7
    • 0031671854 scopus 로고    scopus 로고
    • Determination of choline-containing phospholipids in serum with a fiber-optic biosensor
    • Marazuela M.D., and Moreno-Bondi M.C. Determination of choline-containing phospholipids in serum with a fiber-optic biosensor. Anal. Chim. Acta 374 (1998) 19-29
    • (1998) Anal. Chim. Acta , vol.374 , pp. 19-29
    • Marazuela, M.D.1    Moreno-Bondi, M.C.2
  • 8
    • 0034210581 scopus 로고    scopus 로고
    • Chemiluminescent choline biosensor using histidine-modified peroxidase immobilised on metal-chelate substituted beads and choline oxidase immobilised on anion-exchanger beads co-entrapped in a photocrosslinkable polymer
    • Tsafack C., Christophe A., Marquette, Pizzolato, and Blum J. Chemiluminescent choline biosensor using histidine-modified peroxidase immobilised on metal-chelate substituted beads and choline oxidase immobilised on anion-exchanger beads co-entrapped in a photocrosslinkable polymer. Biosens. Bioelectron. 15 (2000) 125-133
    • (2000) Biosens. Bioelectron. , vol.15 , pp. 125-133
    • Tsafack, C.1    Christophe, A.2    Marquette3    Pizzolato4    Blum, J.5
  • 9
    • 0242586073 scopus 로고    scopus 로고
    • Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue
    • Burmeister J.J., Palmer M., and Gerhardt G.A. Ceramic-based multisite microelectrode array for rapid choline measures in brain tissue. Anal. Chim. Acta 481 (2003) 65-74
    • (2003) Anal. Chim. Acta , vol.481 , pp. 65-74
    • Burmeister, J.J.1    Palmer, M.2    Gerhardt, G.A.3
  • 10
    • 0032310427 scopus 로고    scopus 로고
    • Design and development of an amperometric biosensor for acetylcholine determination in brain microdialysates
    • Larsson N., Ruzgas T., Gorton L., Kokaia M., and Kissingerc P. Design and development of an amperometric biosensor for acetylcholine determination in brain microdialysates. Electrochim. Acta 43 (1998) 3541-3554
    • (1998) Electrochim. Acta , vol.43 , pp. 3541-3554
    • Larsson, N.1    Ruzgas, T.2    Gorton, L.3    Kokaia, M.4    Kissingerc, P.5
  • 11
    • 0029021018 scopus 로고
    • Optimization of amperometric microsensors for monitoring choline in the extracellular fluid of brain tissue
    • Garguilo M.G., and Michail A.J. Optimization of amperometric microsensors for monitoring choline in the extracellular fluid of brain tissue. Anal. Chim. 307 (1995) 291-299
    • (1995) Anal. Chim. , vol.307 , pp. 291-299
    • Garguilo, M.G.1    Michail, A.J.2
  • 12
    • 0029745329 scopus 로고    scopus 로고
    • Clark-type oxidase enzyme-based amperometric microbiosensor for sensing glucose, galactose or choline
    • Peteu S.F., Emerson D., and Worden R.M. Clark-type oxidase enzyme-based amperometric microbiosensor for sensing glucose, galactose or choline. Biosens. Bioelectron. 11 (1996) 1059-1071
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 1059-1071
    • Peteu, S.F.1    Emerson, D.2    Worden, R.M.3
  • 13
    • 4644344459 scopus 로고    scopus 로고
    • Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode
    • Yang M.H., Yang Y.H., Yang Y., Shen G.L., and Yu R.Q. Bienzymatic amperometric biosensor for choline based on mediator thionine in situ electropolymerized within a carbon paste electrode. Anal. Biochem. 334 (2004) 127-134
    • (2004) Anal. Biochem. , vol.334 , pp. 127-134
    • Yang, M.H.1    Yang, Y.H.2    Yang, Y.3    Shen, G.L.4    Yu, R.Q.5
  • 14
    • 0029021018 scopus 로고
    • Optimization of amperometric microsensors monitoring choline in extracellular fluid of brain tissue
    • Garguilo M.G., and Michael A.C. Optimization of amperometric microsensors monitoring choline in extracellular fluid of brain tissue. Anal. Chim. Acta 307 (1995) 291-299
    • (1995) Anal. Chim. Acta , vol.307 , pp. 291-299
    • Garguilo, M.G.1    Michael, A.C.2
  • 15
    • 0342819025 scopus 로고
    • Helical, microtubules of graphitic carbon
    • Iijima S. Helical, microtubules of graphitic carbon. Nature 354 (1991) 56-58
    • (1991) Nature , vol.354 , pp. 56-58
    • Iijima, S.1
  • 16
    • 0038033665 scopus 로고
    • Single shell carbon nanotubes of one nanometer diameter
    • Iijima S., and Ichihashi T. Single shell carbon nanotubes of one nanometer diameter. Nature 363 (1993) 603-605
    • (1993) Nature , vol.363 , pp. 603-605
    • Iijima, S.1    Ichihashi, T.2
  • 17
    • 0036680187 scopus 로고    scopus 로고
    • Review of the doping of carbon nanotubes (multi-walled and single-walled)
    • Duclaux L. Review of the doping of carbon nanotubes (multi-walled and single-walled). Carbon 40 (2002) 1751-1764
    • (2002) Carbon , vol.40 , pp. 1751-1764
    • Duclaux, L.1
  • 18
    • 0036558165 scopus 로고    scopus 로고
    • Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes
    • Wang J., Li M., Shi Z., Li N., and Gu Z. Direct electrochemistry of cytochrome c at a glassy carbon electrode modified with single-wall carbon nanotubes. Anal. Chem. 74 (2002) 1993-1998
    • (2002) Anal. Chem. , vol.74 , pp. 1993-1998
    • Wang, J.1    Li, M.2    Shi, Z.3    Li, N.4    Gu, Z.5
  • 20
    • 0037420379 scopus 로고    scopus 로고
    • Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors
    • Wang J., Musameh M., and Lin Y. Solubilization of carbon nanotubes by nafion toward the preparation of amperometric biosensors. J. Am. Chem. Soc. 125 (2003) 2408-2409
    • (2003) J. Am. Chem. Soc. , vol.125 , pp. 2408-2409
    • Wang, J.1    Musameh, M.2    Lin, Y.3
  • 23
  • 25
    • 0035120680 scopus 로고    scopus 로고
    • Electroanalysis of ascorbate and dopamine at a gold electrode modified with a positively charged self-assembled monolayer
    • Raj C.R., and Ohsaka T. Electroanalysis of ascorbate and dopamine at a gold electrode modified with a positively charged self-assembled monolayer. J. Electroanal. Chem. 496 (2001) 44-49
    • (2001) J. Electroanal. Chem. , vol.496 , pp. 44-49
    • Raj, C.R.1    Ohsaka, T.2
  • 26
    • 0032851128 scopus 로고    scopus 로고
    • A ferric chloride pre-treatment to prevent calcification of nafion membrane used for implantable biosensors
    • Valdes T.I., and Moussy F. A ferric chloride pre-treatment to prevent calcification of nafion membrane used for implantable biosensors. Biosens. Bioelectron. 14 (1999) 579-585
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 579-585
    • Valdes, T.I.1    Moussy, F.2
  • 27
    • 0030579569 scopus 로고    scopus 로고
    • Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide
    • Li H., Tan S.W., and Ge H.L. Silica sol-gel immobilized amperometric biosensor for hydrogen peroxide. Anal. Chim. Acta 335 (1996) 137-145
    • (1996) Anal. Chim. Acta , vol.335 , pp. 137-145
    • Li, H.1    Tan, S.W.2    Ge, H.L.3
  • 28
    • 0038357699 scopus 로고    scopus 로고
    • Sol-gel-derived titanium oxide/copolymer composite based glucose biosensor
    • Chen X., and Dong S.J. Sol-gel-derived titanium oxide/copolymer composite based glucose biosensor. Biosens. Bioelectron. 18 (2003) 999-1004
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 999-1004
    • Chen, X.1    Dong, S.J.2
  • 29
    • 2542475503 scopus 로고    scopus 로고
    • Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode
    • Li T., Yao Z.H., and Ding L. Development of an amperometric biosensor based on glucose oxidase immobilized through silica sol-gel film onto Prussian Blue modified electrode. Sens. Actuators B: Chem. 101 (2004) 155-160
    • (2004) Sens. Actuators B: Chem. , vol.101 , pp. 155-160
    • Li, T.1    Yao, Z.H.2    Ding, L.3
  • 30
    • 0036179366 scopus 로고    scopus 로고
    • Some new aspects in biosensors
    • Dong S.J., and Chen X. Some new aspects in biosensors. Rev. Mol. Biotechnol. 82 (2002) 303-323
    • (2002) Rev. Mol. Biotechnol. , vol.82 , pp. 303-323
    • Dong, S.J.1    Chen, X.2
  • 31
    • 0032129145 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material
    • Wang B.Q., Li B., Deng Q., and Dong S.J. Amperometric glucose biosensor based on sol-gel organic-inorganic hybrid material. Anal. Chem. 70 (1998) 3170-3174
    • (1998) Anal. Chem. , vol.70 , pp. 3170-3174
    • Wang, B.Q.1    Li, B.2    Deng, Q.3    Dong, S.J.4
  • 34
    • 0000749090 scopus 로고    scopus 로고
    • Structural and electronic properties of pentagon-heptagon pair defects in carbon nanotubes
    • Charlier J.C., Ebbesen T.W., and Lambin Ph. Structural and electronic properties of pentagon-heptagon pair defects in carbon nanotubes. Phys. Rev. B 53 (1996) 11108-11113
    • (1996) Phys. Rev. B , vol.53 , pp. 11108-11113
    • Charlier, J.C.1    Ebbesen, T.W.2    Lambin, Ph.3
  • 37
    • 0031568945 scopus 로고    scopus 로고
    • A chemiluminescent flow sensing device for determination of choline and phospholipase D activity in biological samples
    • Pavel R., Ferri E.N., Girotti S., Rauchova H., Carrea G., Bovara R., Fini F., and Aldo R. A chemiluminescent flow sensing device for determination of choline and phospholipase D activity in biological samples. Anal. Biochem. 245 (1997) 133-140
    • (1997) Anal. Biochem. , vol.245 , pp. 133-140
    • Pavel, R.1    Ferri, E.N.2    Girotti, S.3    Rauchova, H.4    Carrea, G.5    Bovara, R.6    Fini, F.7    Aldo, R.8
  • 38
    • 0032144910 scopus 로고    scopus 로고
    • Direct bioelectrochemical monitoring of choline oxidase kinetic behaviour in Langmuir-Blodgett nanostructure
    • Girard-Egrot A.P., Morelis R.M., and Coulet P.R. Direct bioelectrochemical monitoring of choline oxidase kinetic behaviour in Langmuir-Blodgett nanostructure. Bioelectrochem. Bioenerg. 46 (1998) 39-44
    • (1998) Bioelectrochem. Bioenerg. , vol.46 , pp. 39-44
    • Girard-Egrot, A.P.1    Morelis, R.M.2    Coulet, P.R.3
  • 39
    • 1842835758 scopus 로고    scopus 로고
    • Amperometric determination of choline released from rat submandibular gland acinar cells using a choline oxidase biosensor
    • Razola S.S., Pochet S., Grosfils K., and Kauffmann J.M. Amperometric determination of choline released from rat submandibular gland acinar cells using a choline oxidase biosensor. Biosens. Bioelectron. 18 (2003) 185-191
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 185-191
    • Razola, S.S.1    Pochet, S.2    Grosfils, K.3    Kauffmann, J.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.