메뉴 건너뛰기




Volumn 17, Issue 6, 2010, Pages 761-767

What's the Control in Studies Measuring the Effect of Computer-Aided Detection (CAD) on Observer Performance?

Author keywords

CADe; diagnostic accuracy; MRMC study; ROC analysis

Indexed keywords

ARTICLE; COLON POLYP; COMPUTED TOMOGRAPHIC COLONOGRAPHY; COMPUTER ASSISTED DIAGNOSIS; CONTROLLED STUDY; DATA ANALYSIS; DIAGNOSTIC ACCURACY; HUMAN; IMAGE ANALYSIS; INTERMETHOD COMPARISON; LUNG NODULE; MAJOR CLINICAL STUDY; OBSERVER BIAS; OBSERVER VARIATION; PRIORITY JOURNAL; RADIOLOGIST; RECEIVER OPERATING CHARACTERISTIC; SENSITIVITY AND SPECIFICITY; SEQUENTIAL ANALYSIS; THORAX RADIOGRAPHY;

EID: 77951826596     PISSN: 10766332     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.acra.2010.01.018     Document Type: Article
Times cited : (12)

References (18)
  • 1
    • 12144290346 scopus 로고    scopus 로고
    • Lung Image Database Consortium Research Group. Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: contemporary research topics relevant to the lung image database consortium
    • Dodd L.E., Wagner R.F., Armato S.G., et al. Lung Image Database Consortium Research Group. Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: contemporary research topics relevant to the lung image database consortium. Acad Radiol 11 (2004) 462-475
    • (2004) Acad Radiol , vol.11 , pp. 462-475
    • Dodd, L.E.1    Wagner, R.F.2    Armato, S.G.3
  • 2
    • 34250162528 scopus 로고    scopus 로고
    • Assessment of medical imaging systems and computer aids: a tutorial review
    • Wagner R.F., Metz C.E., and Campbell G. Assessment of medical imaging systems and computer aids: a tutorial review. Acad Radiol 14 (2007) 723-748
    • (2007) Acad Radiol , vol.14 , pp. 723-748
    • Wagner, R.F.1    Metz, C.E.2    Campbell, G.3
  • 3
    • 33750353858 scopus 로고    scopus 로고
    • Small pulmonary nodules: effect of two computer-aided detection systems on radiologists performance
    • Das M., Muhlenbruch G., Mahnken A.H., et al. Small pulmonary nodules: effect of two computer-aided detection systems on radiologists performance. Radiology 241 (2006) 564-571
    • (2006) Radiology , vol.241 , pp. 564-571
    • Das, M.1    Muhlenbruch, G.2    Mahnken, A.H.3
  • 4
    • 33845634872 scopus 로고    scopus 로고
    • Computed tomographic colonography: assessment of radiologists performance with and without computer-aided detection
    • Halligan S., Altman D.G., Mallett S., et al. Computed tomographic colonography: assessment of radiologists performance with and without computer-aided detection. Gastroenterology 131 (2006) 1690-1699
    • (2006) Gastroenterology , vol.131 , pp. 1690-1699
    • Halligan, S.1    Altman, D.G.2    Mallett, S.3
  • 5
    • 34047243811 scopus 로고    scopus 로고
    • Influence of computer-aided detection on performance of screening mammography
    • Fenton J.J., Taplin S.H., Carney P.A., et al. Influence of computer-aided detection on performance of screening mammography. N Engl J Med 356 (2007) 1399-1409
    • (2007) N Engl J Med , vol.356 , pp. 1399-1409
    • Fenton, J.J.1    Taplin, S.H.2    Carney, P.A.3
  • 6
    • 22544470854 scopus 로고    scopus 로고
    • Computer-aided detection with screening mammography in a university hospital setting
    • Birdwell R.L., Bandodkar P., and Ikeda D.M. Computer-aided detection with screening mammography in a university hospital setting. Radiology 236 (2005) 451-457
    • (2005) Radiology , vol.236 , pp. 451-457
    • Birdwell, R.L.1    Bandodkar, P.2    Ikeda, D.M.3
  • 7
    • 1342263571 scopus 로고    scopus 로고
    • Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system
    • Gur D., Sumkin J.H., Rockette H.E., et al. Changes in breast cancer detection and mammography recall rates after the introduction of a computer-aided detection system. J Natl Cancer Inst 96 (2004) 185-190
    • (2004) J Natl Cancer Inst , vol.96 , pp. 185-190
    • Gur, D.1    Sumkin, J.H.2    Rockette, H.E.3
  • 8
    • 32944481413 scopus 로고    scopus 로고
    • Impact of computer-aided detection in a regional screening mammography program
    • Cupples T.E., Cunningham J.E., and Reynolds J.C. Impact of computer-aided detection in a regional screening mammography program. AJR Am J Radiol 185 (2005) 944-950
    • (2005) AJR Am J Radiol , vol.185 , pp. 944-950
    • Cupples, T.E.1    Cunningham, J.E.2    Reynolds, J.C.3
  • 9
    • 0034194196 scopus 로고    scopus 로고
    • Assessing mammographers' accuracy: a comparison of clinical and test performance
    • Rutter C.M., and Taplin S. Assessing mammographers' accuracy: a comparison of clinical and test performance. J Clin Epidemiol 53 (2000) 443-450
    • (2000) J Clin Epidemiol , vol.53 , pp. 443-450
    • Rutter, C.M.1    Taplin, S.2
  • 10
    • 0037380176 scopus 로고    scopus 로고
    • ROC-type assessment of medical imaging and CAD technologies
    • Gur D. ROC-type assessment of medical imaging and CAD technologies. Acad Radiol 10 (2003) 402-403
    • (2003) Acad Radiol , vol.10 , pp. 402-403
    • Gur, D.1
  • 11
    • 34250213693 scopus 로고    scopus 로고
    • Objectively measuring and comparing performance levels of diagnostic imaging systems and practices
    • Gur D. Objectively measuring and comparing performance levels of diagnostic imaging systems and practices. Acad Radiol 14 (2007) 641-642
    • (2007) Acad Radiol , vol.14 , pp. 641-642
    • Gur, D.1
  • 12
    • 77953663577 scopus 로고    scopus 로고
    • Available at, Accessed February 16, 2010
    • Draft Guidance for Industry and FDA Staff, page 12. Available at www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/ucm187277.htm. Accessed February 16, 2010.
    • Draft Guidance for Industry and FDA Staff, page 12
  • 14
    • 20744456440 scopus 로고    scopus 로고
    • CT colonography reporting and data system: a consensus proposal
    • Zalis M.E., Barish M.A., Choi J.R., et al. CT colonography reporting and data system: a consensus proposal. Radiology 236 (2005) 3-9
    • (2005) Radiology , vol.236 , pp. 3-9
    • Zalis, M.E.1    Barish, M.A.2    Choi, J.R.3
  • 15
    • 77952308429 scopus 로고    scopus 로고
    • Bias, underestimation of risk and loss of statistical power in patient-level analyses of lesion detection
    • Obuchowski N.A., Mazzone P.J., and Dachman A.H. Bias, underestimation of risk and loss of statistical power in patient-level analyses of lesion detection. Eur Radiol 20 (2009) 584-594
    • (2009) Eur Radiol , vol.20 , pp. 584-594
    • Obuchowski, N.A.1    Mazzone, P.J.2    Dachman, A.H.3
  • 16
    • 0023710206 scopus 로고
    • Comparing areas under two or more correlated receiver operating characteristic curves: a nonparametric approach
    • DeLong E., DeLong D., and Clarke-Pearson D. Comparing areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 44 (1988) 837-845
    • (1988) Biometrics , vol.44 , pp. 837-845
    • DeLong, E.1    DeLong, D.2    Clarke-Pearson, D.3
  • 17
    • 0030966854 scopus 로고    scopus 로고
    • Nonparametric analysis of clustered ROC curve data
    • Obuchowski N.A. Nonparametric analysis of clustered ROC curve data. Biometrics 53 (1997) 170-180
    • (1997) Biometrics , vol.53 , pp. 170-180
    • Obuchowski, N.A.1
  • 18
    • 0000889433 scopus 로고
    • Hypothesis testing of the diagnostic accuracy for multiple diagnostic tests: an ANOVA approach with dependent observations
    • Obuchowski N.A., and Rockette H.E. Hypothesis testing of the diagnostic accuracy for multiple diagnostic tests: an ANOVA approach with dependent observations. Commun Stat Simulation Comput 24 (1995) 285-308
    • (1995) Commun Stat Simulation Comput , vol.24 , pp. 285-308
    • Obuchowski, N.A.1    Rockette, H.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.