메뉴 건너뛰기




Volumn 35, Issue 9, 2010, Pages 931-938

Craniocervical fixation with occipital condyle screws: Biomechanical analysis of a novel technique

Author keywords

Biomechanics; Condyle screw; Craniocervical instability; Craniocervical junction; Craniovertebral junction; Occipital condyle; Occipitalcondyle cervical fusion; Occipitocervical fusion; Occipitocervical junction

Indexed keywords

ADULT; AGED; ARTICLE; ATLANTOOCCIPITAL JOINT; BIOMECHANICS; BONE PLATE; BONE SCREW; COMPUTER ASSISTED TOMOGRAPHY; CRANIOCERVICAL SPINE FUSION; FEMALE; HUMAN; HUMAN EXPERIMENT; JOINT STIFFNESS; MALE; OCCIPITAL BONE; OCCIPITAL CONDYLE; OCCIPITAL CONDYLE SCREW; PLATE FIXATION; PRIORITY JOURNAL; RANGE OF MOTION; SPINE FUSION;

EID: 77951768553     PISSN: 03622436     EISSN: 15281159     Source Type: Journal    
DOI: 10.1097/BRS.0b013e3181c16f9a     Document Type: Article
Times cited : (52)

References (44)
  • 1
    • 0023684241 scopus 로고
    • Moment-rotation relationships of the ligamentous occipito-atlanto-axial complex
    • Goel VK, Clark CR, Gallaes K, et al. Moment-rotation relationships of the ligamentous occipito-atlanto-axial complex. J Biomech 1988;21:673-680
    • (1988) J Biomech , vol.21 , pp. 673-680
    • Goel, V.K.1    Clark, C.R.2    Gallaes, K.3
  • 2
    • 0030845942 scopus 로고    scopus 로고
    • Craniovertebral junction anomalies: Diagnosis and management
    • Menezes AH. Craniovertebral junction anomalies: diagnosis and management. Semin Pediatr Neurol 1997;4:209-223
    • (1997) Semin Pediatr Neurol , vol.4 , pp. 209-223
    • Menezes, A.H.1
  • 3
    • 34547683567 scopus 로고    scopus 로고
    • Occipitocervical fusion with rigid internal fixation: Long-term follow-up data in 69 patients
    • Nockels RP, Shaffrey CI, Kanter AS, et al. Occipitocervical fusion with rigid internal fixation: long-term follow-up data in 69 patients. J Neurosurg Spine 2007;7:117-123
    • (2007) J Neurosurg Spine , vol.7 , pp. 117-123
    • Nockels, R.P.1    Shaffrey, C.I.2    Kanter, A.S.3
  • 4
    • 21244448815 scopus 로고    scopus 로고
    • Indications for surgery and stabilization techniques of the occipito-cervical junction
    • Vaccaro AR, Lim MR, Lee JY. Indications for surgery and stabilization techniques of the occipito-cervical junction. Injury 2005;36(suppl 2): B44-53.
    • (2005) Injury , vol.36 , Issue.SUPPL. 2
    • Vaccaro, A.R.1    Lim, M.R.2    Lee, J.Y.3
  • 5
    • 0023629793 scopus 로고
    • Occipitocervical fusion. Indications, technique, and long-term results in thirteen patients
    • Wertheim SB, Bohlman HH. Occipitocervical fusion. Indications, technique, and long-term results in thirteen patients. J Bone Joint Surg Am 1987;69: 833-836
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 833-836
    • Wertheim, S.B.1    Bohlman, H.H.2
  • 6
    • 33750621452 scopus 로고    scopus 로고
    • Anatomical, biomechanical, and practical considerations in posterior occipitocervical instrumentation
    • Wolfla CE. Anatomical, biomechanical, and practical considerations in posterior occipitocervical instrumentation. Spine J 2006;6:225S-32S.
    • (2006) Spine J , vol.6
    • Wolfla, C.E.1
  • 8
    • 0028284239 scopus 로고
    • Plate and screw fixation for atlanto-axial subluxation
    • Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 1994;129:47-53.
    • (1994) Acta Neurochir (Wien) , vol.129 , pp. 47-53
    • Goel, A.1    Laheri, V.2
  • 9
    • 0034005748 scopus 로고    scopus 로고
    • Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities
    • Grob D. Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities. J Orthop Sci 2000;5:82-87
    • (2000) J Orthop Sci , vol.5 , pp. 82-87
    • Grob, D.1
  • 10
    • 0026036180 scopus 로고
    • Posterior occipitocervical fusion. A preliminary report of a new technique
    • Grob D, Dvorak J, Panjabi M, et al. Posterior occipitocervical fusion. A preliminary report of a new technique. Spine 1991;16:S17-24.
    • (1991) Spine , vol.16
    • Grob, D.1    Dvorak, J.2    Panjabi, M.3
  • 11
    • 0032893119 scopus 로고    scopus 로고
    • Occipital screw pullout strength. A biomechanical investigation of occipital morphology
    • Haher TR, Yeung AW, Caruso SA, et al. Occipital screw pullout strength. A biomechanical investigation of occipital morphology. Spine 1999;24:5-9.
    • (1999) Spine , vol.24 , pp. 5-9
    • Haher, T.R.1    Yeung, A.W.2    Caruso, S.A.3
  • 12
    • 0014051192 scopus 로고
    • Occipito-cervical fusion. Indications, technique and results
    • Hamblen DL. Occipito-cervical fusion. Indications, technique and results. J Bone Joint Surg Br 1967;49:33-45.
    • (1967) J Bone Joint Surg Br , vol.49 , pp. 33-45
    • Hamblen, D.L.1
  • 14
    • 85047684471 scopus 로고    scopus 로고
    • Cadaveric study for placement of occipital condyle screws: Technique and effects on surrounding anatomic structures
    • La Marca F, Zubay G, Morrison T, et al. Cadaveric study for placement of occipital condyle screws: technique and effects on surrounding anatomic structures. J Neurosurg Spine 2008;9:347-353
    • (2008) J Neurosurg Spine , vol.9 , pp. 347-353
    • La Marca, F.1    Zubay, G.2    Morrison, T.3
  • 15
    • 0038580619 scopus 로고    scopus 로고
    • Biomechanical evaluation of new posterior occipitocervical instrumentation system
    • Currier BL, Papagelopoulos PJ, Neale PG, et al. Biomechanical evaluation of new posterior occipitocervical instrumentation system. Clin Orthop Relat Res 2003;103-115
    • (2003) Clin Orthop Relat Res , pp. 103-115
    • Currier, B.L.1    Papagelopoulos, P.J.2    Neale, P.G.3
  • 16
    • 0036293816 scopus 로고    scopus 로고
    • Inverted-hook occipital clamp system in occipitocervical fixation. Technical note
    • Faure A, Monteiro R, Hamel O, et al. Inverted-hook occipital clamp system in occipitocervical fixation. Technical note. J Neurosurg 2002;97:135-141
    • (2002) J Neurosurg , vol.97 , pp. 135-141
    • Faure, A.1    Monteiro, R.2    Hamel, O.3
  • 17
    • 0037347296 scopus 로고    scopus 로고
    • Craniovertebral junction fixation with transarticular screws: Biomechanical analysis of a novel technique
    • Gonzalez LF, Crawford NR, Chamberlain RH, et al. Craniovertebral junction fixation with transarticular screws: biomechanical analysis of a novel technique. J Neurosurg 2003;98:202-209
    • (2003) J Neurosurg , vol.98 , pp. 202-209
    • Gonzalez, L.F.1    Crawford, N.R.2    Chamberlain, R.H.3
  • 18
    • 0035868977 scopus 로고    scopus 로고
    • Transarticular screw fixation for atlanto-occipital dislocation
    • Grob D. Transarticular screw fixation for atlanto-occipital dislocation. Spine 2001;26:703-707
    • (2001) Spine , vol.26 , pp. 703-707
    • Grob, D.1
  • 19
    • 0029809933 scopus 로고    scopus 로고
    • Posterior rod system of the cervical spine: A new implant allowing optimal screw insertion
    • Jeanneret B. Posterior rod system of the cervical spine: a new implant allowing optimal screw insertion. Eur Spine J 1996;5:350-356
    • (1996) Eur Spine J , vol.5 , pp. 350-356
    • Jeanneret, B.1
  • 20
    • 2542518588 scopus 로고    scopus 로고
    • Malformation associated with ventral compression and instability: One-stage posterior decompression and fusion with a new instrumentation technique
    • discussion 1434-1435
    • Nishikawa M, Ohata K, Baba M, et al. Malformation associated with ventral compression and instability: one-stage posterior decompression and fusion with a new instrumentation technique. Neurosurgery 2004;54:1430-4; discussion 1434-1435
    • (2004) Neurosurgery , vol.54 , pp. 1430-1434
    • Nishikawa, M.1    Ohata, K.2    Baba, M.3
  • 21
    • 0032950211 scopus 로고    scopus 로고
    • Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: Preliminary results
    • Pait TG, Al-Mefty O, Boop FA, et al. Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg 1999;90:1-7.
    • (1999) J Neurosurg , vol.90 , pp. 1-7
    • Pait, T.G.1    Al-Mefty, O.2    Boop, F.A.3
  • 22
    • 0027515433 scopus 로고
    • Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique
    • Smith MD, Anderson P, Grady MS. Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique. Spine 1993;18:1984-1990
    • (1993) Spine , vol.18 , pp. 1984-1990
    • Smith, M.D.1    Anderson, P.2    Grady, M.S.3
  • 23
    • 38949133893 scopus 로고    scopus 로고
    • Biomechanical comparison of occipitoatlantal screw fixation techniques
    • Bambakidis NC, Feiz-Erfan I, Horn EM, et al. Biomechanical comparison of occipitoatlantal screw fixation techniques. J Neurosurg Spine 2008;8: 143-152
    • (2008) J Neurosurg Spine , vol.8 , pp. 143-152
    • Bambakidis, N.C.1    Feiz-Erfan, I.2    Horn, E.M.3
  • 24
    • 60849091374 scopus 로고    scopus 로고
    • Feasibility of occipital condyle screw placement for occipitocervical fixation: A cadaveric study and description of a novel technique
    • Uribe JS, Ramos E, Vale F. Feasibility of occipital condyle screw placement for occipitocervical fixation: a cadaveric study and description of a novel technique. J Spinal Disord Tech 2008;21:540-546
    • (2008) J Spinal Disord Tech , vol.21 , pp. 540-546
    • Uribe, J.S.1    Ramos, E.2    Vale, F.3
  • 25
    • 34047115320 scopus 로고    scopus 로고
    • Augmentation of an anterior lumbar interbody fusion with an anterior plate or pedicle screw fixation: A comparative biomechanical in vitro study
    • Nichols TA, Yantzer BK, Alameda S, et al. Augmentation of an anterior lumbar interbody fusion with an anterior plate or pedicle screw fixation: a comparative biomechanical in vitro study. J Neurosurg Spine 2007;6:267-271
    • (2007) J Neurosurg Spine , vol.6 , pp. 267-271
    • Nichols, T.A.1    Yantzer, B.K.2    Alameda, S.3
  • 26
    • 0022354031 scopus 로고
    • Biomechanical time-tolerance of fresh cadaveric human spine specimens
    • Panjabi MM, Krag M, Summers D, et al. Biomechanical time-tolerance of fresh cadaveric human spine specimens. J Orthop Res 1985;3:292-300.
    • (1985) J Orthop Res , vol.3 , pp. 292-300
    • Panjabi, M.M.1    Krag, M.2    Summers, D.3
  • 27
    • 0035890208 scopus 로고    scopus 로고
    • Posterior C1-C2 fusion with polyaxial screw and rod fixation
    • Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine 2001;26:2467-2471
    • (2001) Spine , vol.26 , pp. 2467-2471
    • Harms, J.1    Melcher, R.P.2
  • 28
    • 18044403901 scopus 로고    scopus 로고
    • Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine
    • Shimamoto N, Cunningham BW, Dmitriev AE, et al. Biomechanical evaluation of stand-alone interbody fusion cages in the cervical spine. Spine 2001; 26:E432-6.
    • (2001) Spine , vol.26
    • Shimamoto, N.1    Cunningham, B.W.2    Dmitriev, A.E.3
  • 29
    • 0027944270 scopus 로고
    • Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study
    • Sasso RC, Jeanneret B, Fischer K, et al. Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study. Spine 1994;19:2364-2368
    • (1994) Spine , vol.19 , pp. 2364-2368
    • Sasso, R.C.1    Jeanneret, B.2    Fischer, K.3
  • 30
    • 0344211464 scopus 로고    scopus 로고
    • Occipitocervical reconstruction with the Ohio Medical Instruments Loop: Results of a multicenter evaluation in 30 cases
    • Singh SK, Rickards L, Apfelbaum RI, et al. Occipitocervical reconstruction with the Ohio Medical Instruments Loop: results of a multicenter evaluation in 30 cases. J Neurosurg 2003;98:239-246
    • (2003) J Neurosurg , vol.98 , pp. 239-246
    • Singh, S.K.1    Rickards, L.2    Apfelbaum, R.I.3
  • 31
    • 0028242259 scopus 로고
    • Extreme lateral transcondylar approach: Technical improvements and lessons learned
    • Babu RP, Sekhar LN, Wright DC. Extreme lateral transcondylar approach: technical improvements and lessons learned. J Neurosurg 1994; 81:49-59.
    • (1994) J Neurosurg , vol.81 , pp. 49-59
    • Babu, R.P.1    Sekhar, L.N.2    Wright, D.C.3
  • 32
    • 0032724843 scopus 로고    scopus 로고
    • Craniocervical junction venous anatomy on enhanced MR images: The suboccipital cavernous sinus
    • Caruso RD, Rosenbaum AE, Chang JK, et al. Craniocervical junction venous anatomy on enhanced MR images: the suboccipital cavernous sinus. AJNR Am J Neuroradiol 1999;20:1127-1131
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 1127-1131
    • Caruso, R.D.1    Rosenbaum, A.E.2    Chang, J.K.3
  • 33
    • 2642679280 scopus 로고    scopus 로고
    • Microsurgical anatomy of the suboccipital segment of the vertebral artery
    • Castillo C, Vinas FC, Gutikhonda M, et al. Microsurgical anatomy of the suboccipital segment of the vertebral artery. Neurol Res 1998;20:201-208
    • (1998) Neurol Res , vol.20 , pp. 201-208
    • Castillo, C.1    Vinas, F.C.2    Gutikhonda, M.3
  • 34
    • 0021838422 scopus 로고
    • Microsurgical anatomy of the region of the foramen magnum
    • de Oliveira E, Rhoton AL Jr, Peace D. Microsurgical anatomy of the region of the foramen magnum. Surg Neurol 1985;24:293-352.
    • (1985) Surg Neurol , vol.24 , pp. 293-352
    • De Oliveira, E.1    Rhoton Jr., A.L.2    Peace, D.3
  • 35
    • 0031712609 scopus 로고    scopus 로고
    • Microsurgical anatomy for lateral approaches to the foramen magnum with special reference to transcondylar fossa (supracondylar transjugular tubercle) approach
    • Matsushima T, Natori Y, Katsuta T, et al. Microsurgical anatomy for lateral approaches to the foramen magnum with special reference to transcondylar fossa (supracondylar transjugular tubercle) approach. Skull Base Surg 1998;8:119-125
    • (1998) Skull Base Surg , vol.8 , pp. 119-125
    • Matsushima, T.1    Natori, Y.2    Katsuta, T.3
  • 36
    • 23344451443 scopus 로고    scopus 로고
    • A morphometric analysis of the foramen magnum region as it relates to the transcondylar approach
    • Muthukumar N, Swaminathan R, Venkatesh G, Bhanumathy SP. A morphometric analysis of the foramen magnum region as it relates to the transcondylar approach. Acta Neurochir (Wien) 2005;147:889-895
    • (2005) Acta Neurochir (Wien) , vol.147 , pp. 889-895
    • Muthukumar, N.1    Swaminathan, R.2    Venkatesh, G.3    Bhanumathy, S.P.4
  • 37
    • 0032524653 scopus 로고    scopus 로고
    • Quantitative anatomy of the oc- ciput and the biomechanics of occipital screw fixation
    • discussion 7-8
    • Roberts DA, Doherty BJ, Heggeness MH. Quantitative anatomy of the oc- ciput and the biomechanics of occipital screw fixation. Spine 1998;23: 1100-7; discussion 7-8.
    • (1998) Spine , vol.23 , pp. 1100-1107
    • Roberts, D.A.1    Doherty, B.J.2    Heggeness, M.H.3
  • 38
    • 0030883350 scopus 로고    scopus 로고
    • Microsurgical anatomy of the transcondylar, supracondylar, and paracondylar extensions of the far-lateral approach
    • Wen HT, Rhoton AL, Jr., Katsuta T, et al. Microsurgical anatomy of the transcondylar, supracondylar, and paracondylar extensions of the far-lateral approach. J Neurosurg 1997;87:555-585
    • (1997) J Neurosurg , vol.87 , pp. 555-585
    • Wen, H.T.1    Rhoton Jr., A.L.2    Katsuta, T.3
  • 39
    • 0027483469 scopus 로고
    • Occipitocervical fusion with a fivemillimeter malleable rod and segmental fixation
    • discussion -8
    • Fehlings MG, Errico T, Cooper P, et al. Occipitocervical fusion with a fivemillimeter malleable rod and segmental fixation. Neurosurgery 1993;32: 198-207; discussion -8.
    • (1993) Neurosurgery , vol.32 , pp. 198-207
    • Fehlings, M.G.1    Errico, T.2    Cooper, P.3
  • 40
    • 0032961738 scopus 로고    scopus 로고
    • Occipitocervical fixation usinghooksandscrews for upper cervical instability
    • discussion 30-31
    • Paquis P, Breuil V,LonjonM,et al. Occipitocervical fixation usinghooksandscrews for upper cervical instability. Neurosurgery 1999;44:324-30; discussion 30-31
    • (1999) Neurosurgery , vol.44 , pp. 324-330
    • Paquis, P.1    Breuil, V.2    Lonjon, M.3
  • 41
    • 0347969557 scopus 로고    scopus 로고
    • Development of the spine
    • Herkowitz H. Eismont F. BR ed. Philadelphia: Saunders
    • Bono CP WG. Development of the spine. In Herkowitz H. Eismont F. BR ed. Rothman-Simeone The Spine. Philadelphia: Saunders, 2006:3-15.
    • (2006) Rothman-Simeone the Spine , pp. 3-15
    • Bono Cp, W.G.1
  • 42
    • 0034014213 scopus 로고    scopus 로고
    • Trajectory of the hypoglossal nerve in the hypoglossal canal: Significance for the transcondylar approach
    • discussion 10
    • Katsuta T, Matsushima T, Wen HT, et al. Trajectory of the hypoglossal nerve in the hypoglossal canal: significance for the transcondylar approach. Neurol Med Chir (Tokyo) 2000;40:206-9; discussion 10.
    • (2000) Neurol Med Chir (Tokyo) , vol.40 , pp. 206-209
    • Katsuta, T.1    Matsushima, T.2    Wen, H.T.3
  • 43
    • 0032530291 scopus 로고    scopus 로고
    • Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations
    • discussion 55-56
    • Naderi S, Crawford NR, Song GS, et al. Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations. Spine 1998;23:1946-55; discussion 55-56
    • (1998) Spine , vol.23 , pp. 1946-1955
    • Naderi, S.1    Crawford, N.R.2    Song, G.S.3
  • 44
    • 33645773918 scopus 로고    scopus 로고
    • Biomechanics of occipitocervical fixation
    • Anderson PA, Oza AL, Puschak TJ, et al. Biomechanics of occipitocervical fixation. Spine 2006;31:755-761
    • (2006) Spine , vol.31 , pp. 755-761
    • Anderson, P.A.1    Oza, A.L.2    Puschak, T.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.