메뉴 건너뛰기




Volumn 7, Issue 2, 2007, Pages 117-123

Occipitocervical fusion with rigid internal fixation: Long-term follow-up data in 69 patients

Author keywords

Atlantoaxial instability; Craniocervical junction; Occipitocervical instability; Rheumatoid arthritis; Rigid instrumentation; Spinal fusion

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; ATLANTOAXIAL JOINT; ATLANTOOCCIPITAL FUSION; BASILAR MEMBRANE; BONE PLATE; BONE SCREW; CAUSE OF DEATH; FATALITY; FEMALE; FOLLOW UP; GENERAL CONDITION IMPROVEMENT; HUMAN; KYPHOSIS; MAJOR CLINICAL STUDY; MALE; METASTASIS; OCCIPITAL BONE; OSTEOSYNTHESIS; OUTCOME ASSESSMENT; RHEUMATOID ARTHRITIS; SAFETY; SCHOOL CHILD; SPINAL CORD DISEASE; SPINE DISEASE; SPINE FUSION; SURGICAL ANATOMY; SURGICAL MORTALITY; SYMPTOM;

EID: 34547683567     PISSN: 15475654     EISSN: None     Source Type: Journal    
DOI: 10.3171/SPI-07/08/117     Document Type: Article
Times cited : (97)

References (40)
  • 2
    • 0036726887 scopus 로고    scopus 로고
    • Outcome in neurologically impaired patients with craniovertebral junction tuberculosis: Results of combined anteroposterior surgery
    • Arunkumar MJ, Rajshekhar V: Outcome in neurologically impaired patients with craniovertebral junction tuberculosis: results of combined anteroposterior surgery. J Neurosurg 97:166-171, 2002
    • (2002) J Neurosurg , vol.97 , pp. 166-171
    • Arunkumar, M.J.1    Rajshekhar, V.2
  • 4
    • 0036293816 scopus 로고    scopus 로고
    • Inverted-hook occipital clamp system in occipitocervical fixation. Technical note
    • Faure A, Monteiro R, Hamel O, Raoul S, Szapiro J, Alcheikh M, et al: Inverted-hook occipital clamp system in occipitocervical fixation. Technical note. J Neurosurg 97 (1 Suppl):135-141, 2002
    • (2002) J Neurosurg , vol.97 , Issue.1 SUPPL. , pp. 135-141
    • Faure, A.1    Monteiro, R.2    Hamel, O.3    Raoul, S.4    Szapiro, J.5    Alcheikh, M.6
  • 5
    • 0034005748 scopus 로고    scopus 로고
    • Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities
    • Grob D: Posterior occipitocervical fusion in rheumatoid arthritis and other instabilities. J Orthop Sci 5:82-87, 2000
    • (2000) J Orthop Sci , vol.5 , pp. 82-87
    • Grob, D.1
  • 6
    • 0345034762 scopus 로고    scopus 로고
    • Occipitocervical fusion in patients with rheumatoid arthritis
    • Grob D, Schutz U, Plotz G: Occipitocervical fusion in patients with rheumatoid arthritis. Clin Orthop Relat Res 366:46-53, 1999
    • (1999) Clin Orthop Relat Res , vol.366 , pp. 46-53
    • Grob, D.1    Schutz, U.2    Plotz, G.3
  • 7
    • 0036107537 scopus 로고    scopus 로고
    • Radiologic and clinical spectrum of occipital condyle fractures: Retrospective review of 107 consecutive fractures in 95 patients
    • Hanson JA, Deliganis AV, Baxter AB, Cohen WA, Linnau KF, Wilson AJ, et al: Radiologic and clinical spectrum of occipital condyle fractures: retrospective review of 107 consecutive fractures in 95 patients. AJR Am J Roentgenol 178:1261-1268, 2002
    • (2002) AJR Am J Roentgenol , vol.178 , pp. 1261-1268
    • Hanson, J.A.1    Deliganis, A.V.2    Baxter, A.B.3    Cohen, W.A.4    Linnau, K.F.5    Wilson, A.J.6
  • 8
    • 0031685427 scopus 로고    scopus 로고
    • Occipito-cervical fusion with the cervical Cotrel-Dubousset rod system
    • Heidecke V, Rainov NG, Burkert W: Occipito-cervical fusion with the cervical Cotrel-Dubousset rod system. Acta Neurochir (Wien) 140:969-976, 1998
    • (1998) Acta Neurochir (Wien) , vol.140 , pp. 969-976
    • Heidecke, V.1    Rainov, N.G.2    Burkert, W.3
  • 10
    • 0025719057 scopus 로고
    • Posterior spinal osteosynthesis for cervical fracture/dislocation using a flexible multistrand cable system: Technical note
    • Huhn SL, Wolf AL, Ecklund J: Posterior spinal osteosynthesis for cervical fracture/dislocation using a flexible multistrand cable system: technical note. Neurosurgery 29:943-946, 1991
    • (1991) Neurosurgery , vol.29 , pp. 943-946
    • Huhn, S.L.1    Wolf, A.L.2    Ecklund, J.3
  • 11
    • 0032902986 scopus 로고    scopus 로고
    • A biomechanical evaluation of occipitocervical instrumentation: Screw compared with wire fixation
    • Hurlbert RJ, Crawford NR, Choi WG, Williams D, Kostuik JP: A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. J Neurosurg 90 (1 Suppl): 84-90, 1999
    • (1999) J Neurosurg , vol.90 , Issue.1 SUPPL. , pp. 84-90
    • Hurlbert, R.J.1    Crawford, N.R.2    Choi, W.G.3    Williams, D.4    Kostuik, J.P.5
  • 12
    • 0029866439 scopus 로고    scopus 로고
    • Posterior occipitoaxial fusion for atlantoaxial dislocation associated with occipitalized atlas
    • Jain VK, Mittal P, Banerji D, Behari S, Acharya R, Chhabra DK: Posterior occipitoaxial fusion for atlantoaxial dislocation associated with occipitalized atlas. J Neurosurg 84:559-564, 1996
    • (1996) J Neurosurg , vol.84 , pp. 559-564
    • Jain, V.K.1    Mittal, P.2    Banerji, D.3    Behari, S.4    Acharya, R.5    Chhabra, D.K.6
  • 13
    • 0029809933 scopus 로고    scopus 로고
    • Posterior rod system of the cervical spine: A new implant allowing optimal screw insertion
    • Jeanneret B: Posterior rod system of the cervical spine: a new implant allowing optimal screw insertion. Eur Spine J 5:350-356, 1996
    • (1996) Eur Spine J , vol.5 , pp. 350-356
    • Jeanneret, B.1
  • 14
    • 0026625974 scopus 로고
    • The relationship between myocardial blood flow and glucose uptake in ischemic canine myocardium determined with fluorine-18-deoxyglucose
    • Kalff V, Schwaiger M, Nguyen N, McClanahan TB, Gallagher KP: The relationship between myocardial blood flow and glucose uptake in ischemic canine myocardium determined with fluorine-18-deoxyglucose. J Nucl Med 33:1346-1353, 1992
    • (1992) J Nucl Med , vol.33 , pp. 1346-1353
    • Kalff, V.1    Schwaiger, M.2    Nguyen, N.3    McClanahan, T.B.4    Gallagher, K.P.5
  • 15
    • 0026001468 scopus 로고
    • Incidence of subaxial subluxation in patients with generalized rheumatoid arthritis who have had previous occipital cervical fusions
    • Kraus DR, Peppelman WC, Agarwal AK, DeLeeuw HW, Donaldson WF III: Incidence of subaxial subluxation in patients with generalized rheumatoid arthritis who have had previous occipital cervical fusions. Spine 16 (10 Suppl):486-489, 1991
    • (1991) Spine , vol.16 , Issue.10 SUPPL. , pp. 486-489
    • Kraus, D.R.1    Peppelman, W.C.2    Agarwal, A.K.3    DeLeeuw, H.W.4    Donaldson III, W.F.5
  • 16
    • 0028296584 scopus 로고
    • Treatment of nonrheumatoid occipitocervical instability. Internal fixation with the Hartshill-Ransford loop
    • Malcolm GP, Ransford AO, Crockard HA: Treatment of nonrheumatoid occipitocervical instability. Internal fixation with the Hartshill-Ransford loop. J Bone Joint Surg Br 76:357-366, 1994
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 357-366
    • Malcolm, G.P.1    Ransford, A.O.2    Crockard, H.A.3
  • 17
    • 0034661961 scopus 로고    scopus 로고
    • Results of a longer than 10-year follow-up of patients with rheumatoid arthritis treated by occipitocervical fusion
    • Matsunaga S, Ijiri K, Koga H: Results of a longer than 10-year follow-up of patients with rheumatoid arthritis treated by occipitocervical fusion. Spine 25:1749-1753, 2000
    • (2000) Spine , vol.25 , pp. 1749-1753
    • Matsunaga, S.1    Ijiri, K.2    Koga, H.3
  • 18
    • 0035863473 scopus 로고    scopus 로고
    • Significance of occipitoaxial angle in subaxial lesion after occipitocervical fusion
    • Matsunaga S, Onishi T, Sakou T: Significance of occipitoaxial angle in subaxial lesion after occipitocervical fusion. Spine 26:161-165, 2001
    • (2001) Spine , vol.26 , pp. 161-165
    • Matsunaga, S.1    Onishi, T.2    Sakou, T.3
  • 19
    • 0034100707 scopus 로고    scopus 로고
    • Spine update: Cervical spine internal fixation using screw and screw-plate constructs
    • McCullen GM, Garfin SR: Spine update: cervical spine internal fixation using screw and screw-plate constructs. Spine 25:643-652, 2000
    • (2000) Spine , vol.25 , pp. 643-652
    • McCullen, G.M.1    Garfin, S.R.2
  • 20
    • 0031799170 scopus 로고    scopus 로고
    • 3- to 11-year followup of occipitocervical fusion for rheumatoid arthritis
    • Mori T, Matsunaga S, Sunahara N, Sakou T: 3- to 11-year followup of occipitocervical fusion for rheumatoid arthritis. Clin Orthop Relat Res 351:169-179, 1998
    • (1998) Clin Orthop Relat Res , vol.351 , pp. 169-179
    • Mori, T.1    Matsunaga, S.2    Sunahara, N.3    Sakou, T.4
  • 21
    • 0034014691 scopus 로고    scopus 로고
    • Occipitocervical stabilization for myelopathy in patients with rheumatoid arthritis. Implications of not bone-grafting
    • Moskovich R, Crockard HA, Shott S, Ransford AO: Occipitocervical stabilization for myelopathy in patients with rheumatoid arthritis. Implications of not bone-grafting. J Bone Joint Surg Am 82:349-365, 2000
    • (2000) J Bone Joint Surg Am , vol.82 , pp. 349-365
    • Moskovich, R.1    Crockard, H.A.2    Shott, S.3    Ransford, A.O.4
  • 23
    • 33645308776 scopus 로고    scopus 로고
    • Atlantoaxial fixation: Overview of all techniques
    • Mummaneni PV, Haid RW: Atlantoaxial fixation: overview of all techniques. Neurol India 53:408-415, 2005
    • (2005) Neurol India , vol.53 , pp. 408-415
    • Mummaneni, P.V.1    Haid, R.W.2
  • 24
    • 0032530291 scopus 로고    scopus 로고
    • Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations
    • Naderi S, Crawford NR, Song GS, Sonntag VK, Dickman CA: Biomechanical comparison of C1-C2 posterior fixations. Cable, graft, and screw combinations. Spine 23:1946-1956, 1998
    • (1998) Spine , vol.23 , pp. 1946-1956
    • Naderi, S.1    Crawford, N.R.2    Song, G.S.3    Sonntag, V.K.4    Dickman, C.A.5
  • 25
    • 0033927881 scopus 로고    scopus 로고
    • Occipital screws in occipitocervical fusion and their relation to the venous sinuses: An anatomic and radiographic study
    • Nadim Y, Lu J, Sabry FF, Ebraheim N: Occipital screws in occipitocervical fusion and their relation to the venous sinuses: an anatomic and radiographic study. Orthopedics 23:717-719, 2000
    • (2000) Orthopedics , vol.23 , pp. 717-719
    • Nadim, Y.1    Lu, J.2    Sabry, F.F.3    Ebraheim, N.4
  • 26
    • 2542518588 scopus 로고    scopus 로고
    • Chiari I malformation associated with ventral compression and instability: One-stage posterior decompression and fusion with a new instrumentation technique
    • Nishikawa M, Ohata K, Baba M, Terakawa Y, Hara M: Chiari I malformation associated with ventral compression and instability: one-stage posterior decompression and fusion with a new instrumentation technique. Neurosurgery 54:1430-1435, 2004
    • (2004) Neurosurgery , vol.54 , pp. 1430-1435
    • Nishikawa, M.1    Ohata, K.2    Baba, M.3    Terakawa, Y.4    Hara, M.5
  • 27
    • 0032750036 scopus 로고    scopus 로고
    • Biomechanical evaluation of five different occipito-atlan-to-axial fixation techniques
    • Oda I, Abumi K, Sell LC, Haggerty CJ, Cunningham BW, McAfee PC: Biomechanical evaluation of five different occipito-atlan-to-axial fixation techniques. Spine 24:2377-2382, 1999
    • (1999) Spine , vol.24 , pp. 2377-2382
    • Oda, I.1    Abumi, K.2    Sell, L.C.3    Haggerty, C.J.4    Cunningham, B.W.5    McAfee, P.C.6
  • 28
    • 0032950211 scopus 로고    scopus 로고
    • Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: Preliminary results
    • Pait TG, Al-Mefty O, Boop FA, Arnautovic KI, Rahman S, Ceola W: Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg 90 (1 Suppl):1-7, 1999
    • (1999) J Neurosurg , vol.90 , Issue.1 SUPPL. , pp. 1-7
    • Pait, T.G.1    Al-Mefty, O.2    Boop, F.A.3    Arnautovic, K.I.4    Rahman, S.5    Ceola, W.6
  • 29
    • 0032961738 scopus 로고    scopus 로고
    • Occipitocervical fixation using hooks and screws for upper cervical instability
    • Paquis P, Breuil V, Lonjon M, Euller-Ziegler L, Grellier P: Occipitocervical fixation using hooks and screws for upper cervical instability. Neurosurgery 44:324-331, 1999
    • (1999) Neurosurgery , vol.44 , pp. 324-331
    • Paquis, P.1    Breuil, V.2    Lonjon, M.3    Euller-Ziegler, L.4    Grellier, P.5
  • 30
    • 0033560816 scopus 로고    scopus 로고
    • Occipitocervical neutral position. Possible surgical implications
    • Phillips FM, Phillips CS, Wetzel FT, Gelinas C: Occipitocervical neutral position. Possible surgical implications. Spine 24:775-778, 1999
    • (1999) Spine , vol.24 , pp. 775-778
    • Phillips, F.M.1    Phillips, C.S.2    Wetzel, F.T.3    Gelinas, C.4
  • 31
    • 0032864882 scopus 로고    scopus 로고
    • Occipitocervical fusions in children. Retrospective analysis and technical considerations
    • Rodgers WB, Coran DL, Emans JB, Hresko MT, Hall JE: Occipitocervical fusions in children. Retrospective analysis and technical considerations. Clin Orthop Relat Res 364:125-133, 1999
    • (1999) Clin Orthop Relat Res , vol.364 , pp. 125-133
    • Rodgers, W.B.1    Coran, D.L.2    Emans, J.B.3    Hresko, M.T.4    Hall, J.E.5
  • 32
    • 0037442332 scopus 로고    scopus 로고
    • Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique
    • Sandhu FA, Pait TG, Benzel E, Henderson FC: Occipitocervical fusion for rheumatoid arthritis using the inside-outside stabilization technique. Spine 28:414-419, 2003
    • (2003) Spine , vol.28 , pp. 414-419
    • Sandhu, F.A.1    Pait, T.G.2    Benzel, E.3    Henderson, F.C.4
  • 33
    • 0034464608 scopus 로고    scopus 로고
    • Role of onlay grafting with minimal internal fixation for occipitocervical fusion in oncologic patients
    • Sanpakit S, Mansfield TL, Liebsch J: Role of onlay grafting with minimal internal fixation for occipitocervical fusion in oncologic patients. J Spinal Disord 13:382-390, 2000
    • (2000) J Spinal Disord , vol.13 , pp. 382-390
    • Sanpakit, S.1    Mansfield, T.L.2    Liebsch, J.3
  • 34
    • 0027944270 scopus 로고
    • Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study
    • Sasso RC, Jeanneret B, Fischer K, Magerl F: Occipitocervical fusion with posterior plate and screw instrumentation. A long-term follow-up study. Spine 19:2364-2368, 1994
    • (1994) Spine , vol.19 , pp. 2364-2368
    • Sasso, R.C.1    Jeanneret, B.2    Fischer, K.3    Magerl, F.4
  • 35
    • 0034535165 scopus 로고    scopus 로고
    • Pediatric occipitocervical arthrodesis. A review of current options and early evaluation of rigid internal fixation techniques
    • Schultz KD, Petronio J, Haid RW, Rodts GE, Erwood SC, Alexander J, et al: Pediatric occipitocervical arthrodesis. A review of current options and early evaluation of rigid internal fixation techniques. Pediatr Neurosurg 33:169-181, 2000
    • (2000) Pediatr Neurosurg , vol.33 , pp. 169-181
    • Schultz, K.D.1    Petronio, J.2    Haid, R.W.3    Rodts, G.E.4    Erwood, S.C.5    Alexander, J.6
  • 36
    • 0344211464 scopus 로고    scopus 로고
    • Occipitocervical reconstruction with the Ohio Medical Instruments Loop: Results of a multicenter evaluation in 30 cases
    • Singh SK, Rickards L, Apfelbaum RI, Hurlbert RJ, Maiman D, Fehlings MG: Occipitocervical reconstruction with the Ohio Medical Instruments Loop: results of a multicenter evaluation in 30 cases. J Neurosurg 98 (3 Suppl):239-246, 2003
    • (2003) J Neurosurg , vol.98 , Issue.3 SUPPL. , pp. 239-246
    • Singh, S.K.1    Rickards, L.2    Apfelbaum, R.I.3    Hurlbert, R.J.4    Maiman, D.5    Fehlings, M.G.6
  • 37
    • 0027515433 scopus 로고
    • Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique
    • Smith MD, Anderson P, Grady MS: Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique. Spine 18:1984-1990, 1993
    • (1993) Spine , vol.18 , pp. 1984-1990
    • Smith, M.D.1    Anderson, P.2    Grady, M.S.3
  • 38
    • 0033500282 scopus 로고    scopus 로고
    • Rigid occipitocervical fusion
    • Vale FL, Oliver M, Cahill DW: Rigid occipitocervical fusion. J Neurosurg 91 (2 Suppl):144-150, 1999
    • (1999) J Neurosurg , vol.91 , Issue.2 SUPPL. , pp. 144-150
    • Vale, F.L.1    Oliver, M.2    Cahill, D.W.3
  • 39
    • 0023629793 scopus 로고
    • Occipitocervical fusion. Indications, technique, and long-term results in thirteen patients
    • Wertheim SB, Bohlman HH: Occipitocervical fusion. Indications, technique, and long-term results in thirteen patients. J Bone Joint Surg Am 69:833-836, 1987
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 833-836
    • Wertheim, S.B.1    Bohlman, H.H.2
  • 40
    • 0029052831 scopus 로고
    • Occipito-cervical fixation in rheumatoid arthritis-an analysis of surgical risk factors in 163 patients
    • Zygmunt SC, Christensson D, Saveland H, Rydholm U, Alund M: Occipito-cervical fixation in rheumatoid arthritis-an analysis of surgical risk factors in 163 patients. Acta Neurochir (Wien) 135:25-31, 1995
    • (1995) Acta Neurochir (Wien) , vol.135 , pp. 25-31
    • Zygmunt, S.C.1    Christensson, D.2    Saveland, H.3    Rydholm, U.4    Alund, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.