메뉴 건너뛰기




Volumn 42, Issue 5, 2010, Pages 360-364

Completion rate and diagnostic yield of small-bowel capsule endoscopy: 1 vs. 2 frames per second

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL PAIN; ADULT; AGED; ANEMIA; ARTICLE; CAPSULE ENDOSCOPE; CAPSULE ENDOSCOPY; CHRONIC DIARRHEA; CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; GASTROINTESTINAL HEMORRHAGE; HUMAN; IMAGE QUALITY; INTESTINE TUMOR; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; TIME; VIDEORECORDING;

EID: 77951704925     PISSN: 0013726X     EISSN: 14388812     Source Type: Journal    
DOI: 10.1055/s-0029-1243993     Document Type: Article
Times cited : (19)

References (15)
  • 1
    • 33645240408 scopus 로고    scopus 로고
    • Technology Assessment Committee, American Society for Gastrointestinal Endoscopy. ASGE Technology Status Evaluation Report: Wireless capsule endoscopy
    • Mishkin D S., Chuttani R, Croffie J et al. Technology Assessment Committee, American Society for Gastrointestinal Endoscopy. ASGE Technology Status Evaluation Report: wireless capsule endoscopy. Gastrointest Endosc 2006 63 539-545
    • (2006) Gastrointest Endosc , vol.63 , pp. 539-545
    • Mishkin, D.S.1    Chuttani, R.2    Croffie, J.3
  • 2
    • 68549087127 scopus 로고    scopus 로고
    • Capsule enteroscopy of the small intestine
    • Waterman M, Eliakim R. Capsule enteroscopy of the small intestine. Abdom Imaging 2009 34 452-458
    • (2009) Abdom Imaging , vol.34 , pp. 452-458
    • Waterman, M.1    Eliakim, R.2
  • 3
    • 50049092353 scopus 로고    scopus 로고
    • A multicenter randomized comparison of the Endocapsule and the Pillcam SB
    • Cave D R., Fleischer D E., Leighton J A. et al. A multicenter randomized comparison of the Endocapsule and the Pillcam SB. Gastrointest Endosc 2008 68 487-494
    • (2008) Gastrointest Endosc , vol.68 , pp. 487-494
    • Cave, D.R.1    Fleischer, D.E.2    Leighton, J.A.3
  • 4
    • 37449002481 scopus 로고    scopus 로고
    • Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: A randomized study
    • Hartmann D, Eickhoff A, Damian U et al. Diagnosis of small-bowel pathology using paired capsule endoscopy with two different devices: a randomized study. Endoscopy 2007 39 1041-1045
    • (2007) Endoscopy , vol.39 , pp. 1041-1045
    • Hartmann, D.1    Eickhoff, A.2    Damian, U.3
  • 5
    • 54049117745 scopus 로고    scopus 로고
    • Clinical application of OMOM capsule endoscopy in China: A review of 1,068 cases [abstract]
    • Liao Z, Li F, Li Z S. Clinical application of OMOM capsule endoscopy in China: a review of 1,068 cases [abstract]. Gastrointest Endosc 2008 67 AB265
    • (2008) Gastrointest Endosc , vol.67
    • Liao, Z.1    Li, F.2    Li, Z.S.3
  • 6
    • 58649097129 scopus 로고    scopus 로고
    • First clinical trial of the MiRo capsule endoscope by using a novel transmission technology: Electric-field propagation
    • Bang S, Park J Y., Jeong S et al. First clinical trial of the MiRo capsule endoscope by using a novel transmission technology: electric-field propagation. Gastrointest Endosc 2009 69 253-259
    • (2009) Gastrointest Endosc , vol.69 , pp. 253-259
    • Bang, S.1    Park, J.Y.2    Jeong, S.3
  • 7
    • 54049117745 scopus 로고    scopus 로고
    • Complications, completion rate and gastrointestinal transit time of OMOM capsule endoscopy: An analysis with 1,068 cases [abstract]
    • Liao Z, Li F, Li Z S. Complications, completion rate and gastrointestinal transit time of OMOM capsule endoscopy: an analysis with 1,068 cases [abstract]. Gastrointest Endosc 2008 67 AB265
    • (2008) Gastrointest Endosc , vol.67
    • Liao, Z.1    Li, F.2    Li, Z.S.3
  • 8
    • 60149099221 scopus 로고    scopus 로고
    • Reduction of capture rate in the stomach increases small bowel complete examination rate: A prospective randomized, controlled trial
    • Liao Z, Li Z S., Xu C. Reduction of capture rate in the stomach increases small bowel complete examination rate: a prospective randomized, controlled trial. Gastrointest Endosc 2009 69 418-425
    • (2009) Gastrointest Endosc , vol.69 , pp. 418-425
    • Liao, Z.1    Li, Z.S.2    Xu, C.3
  • 9
    • 36849014055 scopus 로고    scopus 로고
    • Shortened duration video capsule endoscopy leads to significantly reduced rate of complete small bowel transit [abstract]
    • Pattullo V, Hansen R, Heap T R. Shortened duration video capsule endoscopy leads to significantly reduced rate of complete small bowel transit [abstract]. Gastrointest Endosc 2007 65 AB176
    • (2007) Gastrointest Endosc , vol.65
    • Pattullo, V.1    Hansen, R.2    Heap, T.R.3
  • 10
    • 75749129045 scopus 로고    scopus 로고
    • Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: A systematic review
    • In press. DOI information: 10.1016/j.gie.2009.09.031
    • Liao Z, Gao R, Li Z S., Xu C. Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review. Gastrointest Endosc 2010 In press. DOI information: 10.1016/j.gie.2009.09.031
    • (2010) Gastrointest Endosc
    • Liao, Z.1    Gao, R.2    Li, Z.S.3    Xu, C.4
  • 11
    • 36549074148 scopus 로고    scopus 로고
    • Initial experience of real-time capsule endoscopy in monitoring progress of the video capsule through the upper GI tract
    • Lai L H., Wong G L., Lau J Y. et al. Initial experience of real-time capsule endoscopy in monitoring progress of the video capsule through the upper GI tract. Gastrointest Endosc 2007 66 1211-1214
    • (2007) Gastrointest Endosc , vol.66 , pp. 1211-1214
    • Lai, L.H.1    Wong, G.L.2    Lau, J.Y.3
  • 12
    • 41749088690 scopus 로고    scopus 로고
    • Clinical impact of a newly developed capsule endoscope: Usefulness of a real-time image viewer for gastric transit abnormality
    • Ogata H, Kumai K, Imaeda H et al. Clinical impact of a newly developed capsule endoscope: usefulness of a real-time image viewer for gastric transit abnormality. J Gastroenterol 2008 43 186-192
    • (2008) J Gastroenterol , vol.43 , pp. 186-192
    • Ogata, H.1    Kumai, K.2    Imaeda, H.3
  • 13
    • 0035074301 scopus 로고    scopus 로고
    • Management of Crohns disease in adults
    • Practice Parameters Committee of the American College of Gastroenterology
    • Hanauer S B., Sandborn W, Practice Parameters Committee of the American College of Gastroenterology. Management of Crohns disease in adults. Am J Gastroenterol 2001 96 635-643
    • (2001) Am J Gastroenterol , vol.96 , pp. 635-643
    • Hanauer, S.B.1    Sandborn, W.2
  • 14
    • 33646742147 scopus 로고    scopus 로고
    • The yield of capsule endoscopy in patients with abdominal pain or diarrhea
    • Fry L C., Carey E J., Shiff A D. et al. The yield of capsule endoscopy in patients with abdominal pain or diarrhea. Endoscopy 2006 38 498-502
    • (2006) Endoscopy , vol.38 , pp. 498-502
    • Fry, L.C.1    Carey, E.J.2    Shiff, A.D.3
  • 15
    • 34547105551 scopus 로고    scopus 로고
    • Prospective multicenter trial of capsule endoscopy in patients with chronic abdominal pain, diarrhea and other signs and symptoms (CEDAP-Plus Study)
    • May A, Manner H, Schneider M et al. Prospective multicenter trial of capsule endoscopy in patients with chronic abdominal pain, diarrhea and other signs and symptoms (CEDAP-Plus Study). Endoscopy 2007 39 606-612
    • (2007) Endoscopy , vol.39 , pp. 606-612
    • May, A.1    Manner, H.2    Schneider, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.