메뉴 건너뛰기




Volumn 35, Issue 2, 2010, Pages 81-87

Dose distribution near thin titanium plate for skull fixation irradiated by a 4-MV photon beam

Author keywords

Monte Carlo simulation; Photon beam; Radiation treatment planning system; Scattered radiation; Titanium plate

Indexed keywords

TITANIUM;

EID: 77951696749     PISSN: 09716203     EISSN: 19983913     Source Type: Journal    
DOI: 10.4103/0971-6203.62199     Document Type: Article
Times cited : (13)

References (25)
  • 2
    • 0024370472 scopus 로고
    • Backscatter dose perturbation at high atomic number interfaces in megavoltage photon beams
    • Das I.J., Khan FM. Backscatter dose perturbation at high atomic number interfaces in megavoltage photon beams. Med Phys 1989;16:367-75.
    • (1989) Med Phys , vol.16 , pp. 367-75
    • Das, I.J.1    Khan, F.M.2
  • 3
    • 10744226022 scopus 로고    scopus 로고
    • Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation: Report of the AAPM radiation therapy committee task group 63
    • Reft C., Alecu R, Das IJ, Gerbi BJ, Keall P, Lief E, et al. Dosimetric considerations for patients with HIP prostheses undergoing pelvic irradiation: Report of the AAPM Radiation Therapy Committee Task Group 63. Med Phys 2003;30:1162-82.
    • (2003) Med Phys , vol.30 , pp. 1162-82
    • Reft, C.1    Alecu, R.2    Das, I.J.3    Gerbi, B.J.4    Keall, P.5    Lief, E.6
  • 4
    • 0037833706 scopus 로고    scopus 로고
    • Calibration of CT hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: The use of the extended CT-scale
    • Coolens C., Childs PJ. Calibration of CT Hounsfield units for radiotherapy treatment planning of patients with metallic hip prostheses: The use of the extended CT-scale. Phys Med Biol 2003;48:1591-603.
    • (2003) Phys Med Biol , vol.48 , pp. 1591-603
    • Coolens, C.1    Childs, P.J.2
  • 5
    • 0035889273 scopus 로고    scopus 로고
    • A study on beams passing through hip prosthesis for pelvic radiation treatment
    • Ding G.X., Yu C. A study on beams passing through hip prosthesis for pelvic radiation treatment. Int J Radiat Oncol Biol Phys 2001;51:1167-75.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 1167-75
    • Ding, G.X.1    Yu, C.2
  • 6
    • 0038510218 scopus 로고    scopus 로고
    • Radiotherapy dose calculations in the presence of hip prostheses
    • Keall P.J., Siebers J V, Jeraj R, Mohan R. Radiotherapy dose calculations in the presence of hip prostheses. Med Dosim 2003;28:107-12.
    • (2003) Med Dosim , vol.28 , pp. 107-12
    • Keall, P.J.1    Siebers, J.V.2    Jeraj, R.3    Mohan, R.4
  • 7
    • 0346218242 scopus 로고    scopus 로고
    • Monte Carlo dose calculations in the treatment of a pelvis with implant and comparison with pencil-beam calculations
    • Laub W., Nüsslin F. Monte Carlo dose calculations in the treatment of a pelvis with implant and comparison with pencil-beam calculations. Med Dosim 2003;28:229-33.
    • (2003) Med Dosim , vol.28 , pp. 229-33
    • Laub, W.1    Nüsslin, F.2
  • 8
    • 0036103853 scopus 로고    scopus 로고
    • The effect of metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations
    • Lin S.Y., Chu TC, Lin J P, Liu M T. The effect of metal hip prosthesis on the radiation dose in therapeutic photon beam irradiations. Appl Radiat Isot 2002;57:17-23.
    • (2002) Appl Radiat Isot , vol.57 , pp. 17-23
    • Lin, S.Y.1    Chu, T.C.2    Lin, J.P.3    Liu, M.T.4
  • 9
    • 0142182110 scopus 로고    scopus 로고
    • Dose perturbation in the presence of metallic implants: Treatment planning system versus Monte Carlo simulations
    • Wieslander E., Knöös T. Dose perturbation in the presence of metallic implants: Treatment planning system versus Monte Carlo simulations. Phys Med Biol 2003;48:3295-305.
    • (2003) Phys Med Biol , vol.48 , pp. 3295-305
    • Wieslander, E.1    Knöös, T.2
  • 10
    • 32544456357 scopus 로고    scopus 로고
    • Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy
    • Beyzadeoglu M., Dirican B, Oysul K, Ozen J, Ucok O. Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy. Dentomaxillofac Radiol 2006;35:14-7.
    • (2006) Dentomaxillofac Radiol , vol.35 , pp. 14-7
    • Beyzadeoglu, M.1    Dirican, B.2    Oysul, K.3    Ozen, J.4    Ucok, O.5
  • 11
    • 0025067377 scopus 로고
    • Measurement of absorbed dose near metal and dental material interfaces irradiated by x-and gamma-ray therapy beams
    • Farahani M., Eichmiller FC, McLaughlin WL. Measurement of absorbed dose near metal and dental material interfaces irradiated by x-and gamma-ray therapy beams. Phys Med Biol 1990;35:369-85.
    • (1990) Phys Med Biol , vol.35 , pp. 369-85
    • Farahani, M.1    Eichmiller, F.C.2    McLaughlin, W.L.3
  • 13
    • 0036516426 scopus 로고    scopus 로고
    • Evaluation of a device for attenuation of electron release from dental restorations in a therapeutic radiation field
    • Reitemeier B., Reitemeier G, Schmidt A, Schaal W, Blochberger P, Lehmann D. Evaluation of a device for attenuation of electron release from dental restorations in a therapeutic radiation field. J Prosthet Dent 2002;87:323-7.
    • (2002) J Prosthet Dent , vol.87 , pp. 323-7
    • Reitemeier, B.1    Reitemeier, G.2    Schmidt, A.3    Schaal, W.4    Blochberger, P.5    Lehmann, D.6
  • 14
    • 33845229491 scopus 로고    scopus 로고
    • High density dental materials and radiotherapy planning: Comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements
    • Spirydovich S., Papiez L, Langer M, Sandison G, Thai V. High density dental materials and radiotherapy planning: Comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements, Radiother Oncol 2006;81:309-14.
    • (2006) Radiother Oncol , vol.81 , pp. 309-14
    • Spirydovich, S.1    Papiez, L.2    Langer, M.3    Sandison, G.4    Thai, V.5
  • 16
    • 77951682082 scopus 로고    scopus 로고
    • Lecture notes of EGS4 course at KEK
    • Hirayama H., Namito Y. Lecture Notes of EGS4 Course at KEK. KEK Internal 99-5; 1999. p. 41-2.
    • (1999) KEK Internal 99-5 , pp. 41-2
    • Hirayama, H.1    Namito, Y.2
  • 17
    • 0036130665 scopus 로고    scopus 로고
    • Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code
    • Sheikh-Bagheri D, Rogers DW. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med Phys 2002;29:391-402.
    • (2002) Med Phys , vol.29 , pp. 391-402
    • Sheikh-Bagheri, D.1    Rogers, D.W.2
  • 18
    • 26244462962 scopus 로고    scopus 로고
    • Post-irradiation colouration of gafchromic EBT radiochromic film
    • Cheung T., Butson MJ, Yu PK. Post-irradiation colouration of Gafchromic EBT radiochromic film. Phys Med Biol 2005;50:N281-5.
    • (2005) Phys Med Biol , vol.50
    • Cheung, T.1    Butson, M.J.2    Yu, P.K.3
  • 22
    • 0003414651 scopus 로고
    • Photon, electron, proton and neutron interaction data for body tissues
    • International Commission on Radiation Units and Measurements (ICRU)
    • International Commission on Radiation Units and Measurements (ICRU), Photon, electron, proton and neutron interaction data for body tissues, ICRU Report 46, 12, ICRU; 1992.
    • (1992) ICRU Report 46, 12, ICRU
  • 24
    • 33750896653 scopus 로고    scopus 로고
    • Atomic weights of the elements 2005 (IUPAC technical report)
    • Wieser ME. Atomic weights of the elements 2005 (IUPAC Technical Report). Pure Appl Chem 2006;78:2051-66.
    • (2006) Pure Appl Chem , vol.78 , pp. 2051-66
    • Wieser, M.E.1
  • 25
    • 0034129338 scopus 로고    scopus 로고
    • Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
    • Miften M., Wiesmeyer M, Monthofer S, Krippner K. Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system. Phys Med Biol 1999;45:817-33.
    • (1999) Phys Med Biol , vol.45 , pp. 817-33
    • Miften, M.1    Wiesmeyer, M.2    Monthofer, S.3    Krippner, K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.