Cross-Calibration and Comparison of Variability in 2 Bone Densitometers in a Research Setting: The Framingham Experience

Author keywords

Bone; cross calibration; dual x ray absorptiometry; mineral density

Indexed keywords

ADULT; AGED; ARTICLE; BODY POSITION; BONE DENSITOMETRY; BONE DENSITY; CALIBRATION; CONTROLLED STUDY; DUAL ENERGY X RAY ABSORPTIOMETRY; FEMALE; FEMUR NECK; HIP; HUMAN; HUMAN EXPERIMENT; IN VIVO STUDY; INTERMETHOD COMPARISON; LUMBAR SPINE; MALE; NORMAL HUMAN; ORTHOPEDIC EQUIPMENT; PRIORITY JOURNAL; QUALITY CONTROL; BODY POSTURE; COMPARATIVE STUDY; DEVICES; FEMUR; IMAGE PROCESSING; LUMBAR VERTEBRA; MIDDLE AGED; OBSERVER VARIATION; PHOTON ABSORPTIOMETRY; PREDICTIVE VALUE; REPRODUCIBILITY; STATISTICAL MODEL; VERY ELDERLY;

EID: 77951652555     PISSN: 10946950     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jocd.2010.01.003     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 1242329188 scopus 로고    scopus 로고
    • Technical standardization for dual-energy x-ray absorptiometry
    • The Writing Group for the ISCD Position Development Conference
    • The Writing Group for the ISCD Position Development Conference. Technical standardization for dual-energy x-ray absorptiometry. J Clin Densitom 7 (2004) 27-36
    • (2004) J Clin Densitom , vol.7 , pp. 27-36
  • 2
    • 34547590043 scopus 로고    scopus 로고
    • A generalized least significant change for individuals measured on different DXA systems
    • Shepherd J.A., and Lu Y. A generalized least significant change for individuals measured on different DXA systems. J Clin Densitom 10 (2007) 249-258
    • (2007) J Clin Densitom , vol.10 , pp. 249-258
    • Shepherd, J.A.1    Lu, Y.2
  • 3
    • 42949092049 scopus 로고    scopus 로고
    • Comparing BMD results between two similar DXA systems using the generalized least significant change
    • Shepherd J.A., Morgan S.L., and Lu Y. Comparing BMD results between two similar DXA systems using the generalized least significant change. J Clin Densitom 11 (2008) 237-242
    • (2008) J Clin Densitom , vol.11 , pp. 237-242
    • Shepherd, J.A.1    Morgan, S.L.2    Lu, Y.3
  • 4
    • 0029007705 scopus 로고
    • The effects of analytic software and scan analysis technique on the comparison of dual X-ray absorptiometry with dual photon absorptiometry of the hip in the elderly
    • Kiel D.P., Mercier C.A., Dawson-Hughes B., et al. The effects of analytic software and scan analysis technique on the comparison of dual X-ray absorptiometry with dual photon absorptiometry of the hip in the elderly. J Bone Miner Res 10 (1995) 1130-1136
    • (1995) J Bone Miner Res , vol.10 , pp. 1130-1136
    • Kiel, D.P.1    Mercier, C.A.2    Dawson-Hughes, B.3
  • 5
    • 0043025553 scopus 로고    scopus 로고
    • Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers-bone mineral density and body composition studies
    • Oldroyd B., Smith A.H., and Truscott J.G. Cross-calibration of GE/Lunar pencil and fan-beam dual energy densitometers-bone mineral density and body composition studies. Eur J Clin Nutr 57 (2003) 977-987
    • (2003) Eur J Clin Nutr , vol.57 , pp. 977-987
    • Oldroyd, B.1    Smith, A.H.2    Truscott, J.G.3
  • 6
    • 3342969287 scopus 로고    scopus 로고
    • Dual X-ray absorptiometry: cross-calibration of a new fan-beam system
    • Blake G.M., Harrison E.J., and Adams J.E. Dual X-ray absorptiometry: cross-calibration of a new fan-beam system. Calcif Tissue Int 75 (2004) 7-14
    • (2004) Calcif Tissue Int , vol.75 , pp. 7-14
    • Blake, G.M.1    Harrison, E.J.2    Adams, J.E.3
  • 7
    • 33747370987 scopus 로고    scopus 로고
    • Cross calibration of DXA as part of an equipment replacement program
    • Pearson D., Horton B., and Green D.J. Cross calibration of DXA as part of an equipment replacement program. J Clin Densitom 9 (2006) 287-294
    • (2006) J Clin Densitom , vol.9 , pp. 287-294
    • Pearson, D.1    Horton, B.2    Green, D.J.3
  • 8
    • 0034107179 scopus 로고    scopus 로고
    • Risk factors for longitudinal bone loss in elderly men and women: the Framingham Osteoporosis Study
    • Hannan M.T., Felson D.T., Dawson-Hughes B., et al. Risk factors for longitudinal bone loss in elderly men and women: the Framingham Osteoporosis Study. J Bone Miner Res 15 (2000) 710-720
    • (2000) J Bone Miner Res , vol.15 , pp. 710-720
    • Hannan, M.T.1    Felson, D.T.2    Dawson-Hughes, B.3
  • 9
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 (1986) 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 8744296509 scopus 로고    scopus 로고
    • SAS Institute Inc, SAS Institute Inc, Cary, NC
    • SAS Institute Inc. SAS/STAT® 9.1 user's guide (2004), SAS Institute Inc, Cary, NC
    • (2004) SAS/STAT® 9.1 user's guide
  • 11
    • 42649089473 scopus 로고    scopus 로고
    • Peripheral dual-energy X-ray absorptiometry in the management of osteoporosis: the 2007 ISCD Official Positions
    • Hans D.B., Shepherd J.A., Schwartz E.N., et al. Peripheral dual-energy X-ray absorptiometry in the management of osteoporosis: the 2007 ISCD Official Positions. J Clin Densitom 11 (2008) 188-206
    • (2008) J Clin Densitom , vol.11 , pp. 188-206
    • Hans, D.B.1    Shepherd, J.A.2    Schwartz, E.N.3
  • 12
    • 0030539070 scopus 로고    scopus 로고
    • Multiple imputation after 18+ years
    • Rubin D.B. Multiple imputation after 18+ years. J Am Stat Assoc 91 (1996) 473-489
    • (1996) J Am Stat Assoc , vol.91 , pp. 473-489
    • Rubin, D.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.