메뉴 건너뛰기




Volumn 31, Issue 5, 2010, Pages 1277-1281

Fat suppression with short inversion time inversion-recovery and chemical-shift selective saturation: A dual STIR-CHESS combination prepulse for turbo spin echo pulse sequences

Author keywords

Chemical shift selective (CHESS); Fat suppression; Magnetic resonance imaging (MRI); Short TI inversion recovery (STIR)

Indexed keywords

ARTICLE; CHEMICAL SHIFT SELECTIVE SATURATION; CONTROLLED STUDY; DUAL FAT SUPPRESSION; IMAGING SYSTEM; MAGNETIC FIELD; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SHORT INVERSION TIME INVERSION RECOVERY;

EID: 77951569303     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.22147     Document Type: Article
Times cited : (10)

References (10)
  • 4
    • 0021967474 scopus 로고
    • Chemical shift selective MR imaging using a whole-body magnet
    • Frahm J, Haase A, Hänicke W, Matthaei D, Bomsdorf H, Helzel T. Chemical shift selective MR imaging using a whole-body magnet. Radiology 1985;156:441-444. (Pubitemid 15230257)
    • (1985) Radiology , vol.156 , Issue.2 , pp. 441-444
    • Frahm, J.1    Haase, A.2    Hanicke, W.3
  • 5
    • 0026648242 scopus 로고
    • Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck
    • Anzai Y, Lufkin RB, Jabour BA, Hanafee WN. Fat-suppression failure artifacts simulating pathology on frequency-selective fat-suppression MR images of the head and neck. AJNR Am J Neuroradiol 1992;13:879-884.
    • (1992) AJNR Am J Neuroradiol , vol.13 , pp. 879-884
    • Anzai, Y.1    Lufkin, R.B.2    Jabour, B.A.3    Hanafee, W.N.4
  • 6
    • 0022260365 scopus 로고
    • MR imaging: Clinical use of the inversion-recovery sequence
    • Bydder GM, Young IR. MR imaging: clinical use of the inversion-recovery sequence. J Comput Assist Tomogr 1985;9:659-675.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 659-675
    • Bydder, G.M.1    Young, I.R.2
  • 7
    • 0030040197 scopus 로고    scopus 로고
    • Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: Pitfalls in image interpretation
    • Krinsky G, Rofsky NM, Weinreb JC. Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: pitfalls in image interpretation. AJR Am J Roentgenol 1996;166:523-526. (Pubitemid 26065153)
    • (1996) American Journal of Roentgenology , vol.166 , Issue.3 , pp. 523-526
    • Krinsky, G.1    Rofsky, N.M.2    Weinreb, J.C.3
  • 9
    • 0027280888 scopus 로고
    • A chemical shift selective inversion recovery sequence for fat-suppressed MRI: Theory and experimental validation
    • DOI 10.1016/0730-725X(93)90067-N
    • Kaldoudi E, Williams SCR, Barker GJ, Tofts PS. A Chemical shift selective inversion recovery sequence for fat-suppressed MRI: theory and experimental validation. Magn Reson Imaging 1993;11:341-355. (Pubitemid 23150522)
    • (1993) Magnetic Resonance Imaging , vol.11 , Issue.3 , pp. 341-355
    • Kaldoudi, E.1    Williams, S.C.R.2    Barker, G.J.3    Tofts, P.S.4
  • 10
    • 36349030254 scopus 로고    scopus 로고
    • Diffusion-weighted whole-body MR imaging with background body signal suppression: A feasibility study at 3.0 Tesla
    • DOI 10.1007/s00330-007-0717-8
    • Mürtz P, Krautmacher C, Träber F, Gieseke J, Schild HH, Willinek WA. Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla. Eur Radiol 2007;17:3031-3037. (Pubitemid 350142327)
    • (2007) European Radiology , vol.17 , Issue.12 , pp. 3031-3037
    • Murtz, P.1    Krautmacher, C.2    Truber, F.3    Gieseke, J.4    Schild, H.H.5    Willinek, W.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.