메뉴 건너뛰기




Volumn 11, Issue 1, 2000, Pages 56-60

Comparison of short inversion time inversion recovery (STIR) and fat- saturated (chemsat) techniques for background fat intensity suppression in cervical and thoracic MR imaging

Author keywords

Chest; Fat suppression; Magnetic resonance; Neck

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BODY FAT; CANCER SCINTISCANNING; CLINICAL ARTICLE; COMPARATIVE STUDY; FEMALE; FUNCTIONAL ANATOMY; HUMAN; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE QUALITY; MALE; NECK; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; THORAX;

EID: 17044452746     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(200001)11:1<56::AID-JMRI8>3.0.CO;2-D     Document Type: Article
Times cited : (36)

References (15)
  • 2
    • 0026601273 scopus 로고
    • Signal-to-noise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging
    • Constable RT, Smith RC, Gore JC. Signal-to-noise and contrast in fast spin echo (FSE) and inversion recovery FSE imaging. J Comput Assist Tomogr 1992;16:41-47.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 41-47
    • Constable, R.T.1    Smith, R.C.2    Gore, J.C.3
  • 3
    • 0022260365 scopus 로고
    • MR imaging: Clinical use of the inversion recovery sequence
    • Bydder GM, Young IR. MR imaging: clinical use of the inversion recovery sequence. J Comput Assist Tomogr 1985;9:659-675.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 659-675
    • Bydder, G.M.1    Young, I.R.2
  • 4
    • 0023807444 scopus 로고
    • STIR MR imaging of the orbit
    • Atlas SW, Grossman RI, Hackney DB, et al. STIR MR imaging of the orbit. AJR 1988;151:1025-1030.
    • (1988) AJR , vol.151 , pp. 1025-1030
    • Atlas, S.W.1    Grossman, R.I.2    Hackney, D.B.3
  • 5
    • 0028851187 scopus 로고
    • MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences
    • Mehta RC, Marks MP, Hinks RS, et al. MR evaluation of vertebral metastases: T1-weighted, short-inversion-time inversion recovery, fast spin-echo, and inversion-recovery fast spin-echo sequences. AJNR 1995;16:281-288.
    • (1995) AJNR , vol.16 , pp. 281-288
    • Mehta, R.C.1    Marks, M.P.2    Hinks, R.S.3
  • 6
    • 0028961655 scopus 로고
    • Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities
    • Hilfiker P, Zanetti M, Debatin JF, et al. Fast spin-echo inversion-recovery imaging versus fast T2-weighted spin-echo imaging in bone marrow abnormalities. Invest Radiol 1995;253:110-114.
    • (1995) Invest Radiol , vol.253 , pp. 110-114
    • Hilfiker, P.1    Zanetti, M.2    Debatin, J.F.3
  • 7
    • 0028967375 scopus 로고
    • Nontraumatic pediatric musculoskeletal MR imaging: Comparison of conventional and fast-spin-echo short inversion time inversion-recovery technique
    • Weinberger E, Shaw DW, White KS, et al. Nontraumatic pediatric musculoskeletal MR imaging: comparison of conventional and fast-spin-echo short inversion time inversion-recovery technique. Radiology 1995;194:721-726.
    • (1995) Radiology , vol.194 , pp. 721-726
    • Weinberger, E.1    Shaw, D.W.2    White, K.S.3
  • 8
    • 0030074848 scopus 로고    scopus 로고
    • Short tau inversion recovery fat suppression in T2-weighted turbo spin echo-MRI of malignancies of the mouth and oropharynx
    • Dreher A, Muller-Lisse GU, Kretschmar UL, et al. Short tau inversion recovery fat suppression in T2-weighted turbo spin echo-MRI of malignancies of the mouth and oropharynx. Laryngorhinootologie 1996;75:83-87.
    • (1996) Laryngorhinootologie , vol.75 , pp. 83-87
    • Dreher, A.1    Muller-Lisse, G.U.2    Kretschmar, U.L.3
  • 9
    • 0029942317 scopus 로고    scopus 로고
    • Determining depth of invasion of advanced colorectal cancer using MRI short inversion time inversion recovery sequences
    • Masuko E, Homma H, Mezawa S, et al. Determining depth of invasion of advanced colorectal cancer using MRI short inversion time inversion recovery sequences. J Gastroenterol 1996;31:361-365.
    • (1996) J Gastroenterol , vol.31 , pp. 361-365
    • Masuko, E.1    Homma, H.2    Mezawa, S.3
  • 10
    • 0029978378 scopus 로고    scopus 로고
    • "Black blood" T2-weighted inversion-recovery MR imaging of the heart
    • Simonetti OP, Finn JP, White RD, et al. "Black blood" T2-weighted inversion-recovery MR imaging of the heart. Radiology 1996;199:49-57.
    • (1996) Radiology , vol.199 , pp. 49-57
    • Simonetti, O.P.1    Finn, J.P.2    White, R.D.3
  • 11
    • 0030069569 scopus 로고    scopus 로고
    • MR diagnosis of bone contusions of the knee: Comparison of coronal T2-weighted fast spin-echo with fat saturation and fast spin-echo STIR images with conventional STIR images
    • Arndt WF 3rd, Truax AL, Barnett FM, et al. MR diagnosis of bone contusions of the knee: comparison of coronal T2-weighted fast spin-echo with fat saturation and fast spin-echo STIR images with conventional STIR images. AJR 1996;166:119-124.
    • (1996) AJR , vol.166 , pp. 119-124
    • Arndt W.F. III1    Truax, A.L.2    Barnett, F.M.3
  • 12
    • 0025904310 scopus 로고
    • Fast short-tau inversion-recovery MR imaging
    • Fleckenstein JL, Archer BT, Barker BA, et al. Fast short-tau inversion-recovery MR imaging. Radiology 1991;179:499-504.
    • (1991) Radiology , vol.179 , pp. 499-504
    • Fleckenstein, J.L.1    Archer, B.T.2    Barker, B.A.3
  • 13
    • 0026071060 scopus 로고
    • Improved fat suppression in STIR MR imaging: Selecting inversion time through spectral display
    • Shuman WP, Lambert DT, Patten RM, et al. Improved fat suppression in STIR MR imaging: selecting inversion time through spectral display. Radiology 1991;178:885-887.
    • (1991) Radiology , vol.178 , pp. 885-887
    • Shuman, W.P.1    Lambert, D.T.2    Patten, R.M.3
  • 14
    • 0025017455 scopus 로고
    • Benign versus pathologic compression fractures of vertebral bodies: Assessment with conventional spin-echo, chemical-shift, and STIR MR imaging
    • Baker LL, Goodman SB, Perkash I, et al. Benign versus pathologic compression fractures of vertebral bodies: assessment with conventional spin-echo, chemical-shift, and STIR MR imaging. Radiology 1990;174:495-502.
    • (1990) Radiology , vol.174 , pp. 495-502
    • Baker, L.L.1    Goodman, S.B.2    Perkash, I.3
  • 15
    • 0030040197 scopus 로고    scopus 로고
    • Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: Pitfalls in image interpretation
    • Krinsky G, Rofsky NM, Weinreb JC. Nonspecificity of short inversion time inversion recovery (STIR) as a technique of fat suppression: pitfalls in image interpretation. AJR 1996;166:523-526.
    • (1996) AJR , vol.166 , pp. 523-526
    • Krinsky, G.1    Rofsky, N.M.2    Weinreb, J.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.