메뉴 건너뛰기




Volumn 17, Issue 2, 2010, Pages 521-532

Performance of silicone rubber in DC inclined plane tracking tests

Author keywords

Dc; Electrical discharge; Erosion; IEC 60587; Silicone rubber; Tracking

Indexed keywords

BOTTOM ELECTRODES; DC; DC ELECTRICAL; EROSION TEST; HIGHER-DEGREE; INCLINED PLANES; LEAKAGE CURRENT ANALYSIS; LOW FREQUENCY; PEAK LEAKAGE CURRENT; POSITIVE POLARITY; SILICONE RUBBER; SURFACE DAMAGES; SURFACE DEGRADATION; THICK SAMPLES; VOLTAGE LEVELS;

EID: 77951521287     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2010.5448108     Document Type: Article
Times cited : (74)

References (11)
  • 3
    • 3142752548 scopus 로고    scopus 로고
    • Correlation of Damage, Dry Band Arcing Energy, and Temperature in Inclined plane Testing of Silicone Rubber for Outdoor Insulation
    • L. Meyer, S. H. Jayaram, and E. A. Cherney, "Correlation of Damage, Dry Band Arcing Energy, and Temperature in Inclined plane Testing of Silicone Rubber for Outdoor Insulation", IEEE Trans. Dielectr. Electr. Insul., Vol. 11, pp. 424-432, 2004.
    • (2004) IEEE Trans. Dielectr. Electr. Insul. , vol.11 , pp. 424-432
    • Meyer, L.1    Jayaram, S.H.2    Cherney, E.A.3
  • 4
    • 0032688010 scopus 로고    scopus 로고
    • Ac and dc Performance of Polymeric Housing Materials for HV Outdoor Insulators
    • V. M. Moreno and R. S. Gorur, "Ac and dc Performance of Polymeric Housing Materials for HV Outdoor Insulators", IEEE Trans. Dielectr. Electr. Insul., Vol. 6, pp. 342-350 1999.
    • (1999) IEEE Trans. Dielectr. Electr. Insul. , vol.6 , pp. 342-350
    • Moreno, V.M.1    Gorur, R.S.2
  • 5
    • 33244468774 scopus 로고    scopus 로고
    • Investigation of tracking phenomena in outdoor polymeric insulation material under DC voltages using wavelets
    • DOI 10.1109/TPWRD.2005.855485
    • R. Sarathi, S. Chandrasekar, and N. Yoshimura, "Investigation of Tracking Phenomena in Outdoor Polymeric Insulation Material Under DC Voltages Using Wavelets", Trans. Power Delivery, Vol. 21, pp. 515-517, 2006. (Pubitemid 43279846)
    • (2006) IEEE Transactions on Power Delivery , vol.21 , Issue.1 , pp. 515-517
    • Sarathi, R.1    Chandrasekar, S.2    Yoshimura, N.3
  • 6
    • 34249912623 scopus 로고    scopus 로고
    • Analysis of surface degradation of silicone rubber insulation due to tracking under different voltage profiles
    • DOI 10.1007/s00202-006-0029-z
    • S. Chandrasekar, R. Sarathi, and M. G. Danikas, "Analysis of Surface Degradation of Silicone Rubber Insulation Due to Tracking Under Different Voltage Profiles", Archiv fur Elektroteknik, Springer, Berlin, Germany, Vol. 89, No. 6, pp. 489-501, 2006. (Pubitemid 46868561)
    • (2007) Electrical Engineering , vol.89 , Issue.6 , pp. 489-501
    • Chandrasekar, S.1    Sarathi, R.2    Danikas, M.G.3
  • 7
    • 77951543202 scopus 로고    scopus 로고
    • Electrical insulating materials under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion
    • British Standards
    • "Electrical insulating materials under severe ambient conditions - Test methods for evaluating resistance to tracking and erosion", BS EN 60587: British Standards, 2007.
    • (2007) BS EN 60587
  • 9
    • 6344269447 scopus 로고
    • Surface electrical failure in the presence of contaminants: The inclined-plane liquid-contaminant test
    • American Institute of Electrical Engineers, TEECA, AIEE Preprint 61-21
    • K. N. Mathes and E. J. McGowan, "Surface Electrical Failure in the Presence of Contaminants: The Inclined-Plane Liquid-Contaminant Test", Trans., Part 1, Communications and Electronics, American Institute of Electrical Engineers, TEECA, pp. 281-289, 1961, AIEE Preprint 61-21.
    • (1961) Trans., Part 1, Communications and Electronics , pp. 281-289
    • Mathes, K.N.1    McGowan, E.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.