Application of the unified power quality conditioner for mitigating electric arc furnace disturbances

Author keywords

Electric arc furnace; Power quality improvement; Unified power quality conditioner; Voltage disturbances

Indexed keywords

COMPENSATING SIGNAL; CONTROL STRATEGIES; CONVENTIONAL METHODS; CURRENT VECTORS; DC LINKS; ELECTRIC ARC FURNACE; HARMONICS AND INTERHARMONICS; IMPROVING POWER; INTER-HARMONICS; LOW FREQUENCY; PHASE VOLTAGE; POINT OF COMMON COUPLING; POWER QUALITY IMPROVEMENT; REAL SYSTEMS; ROTATING REFERENCE FRAME; SHUNT ACTIVE FILTERS; SIMULATION RESULT; SINUSOIDAL WAVEFORMS; UNIFIED POWER QUALITY CONDITIONERS; VOLTAGE DISTURBANCES; VOLTAGE REFERENCE;

EID: 77951260233     PISSN: 10783466     EISSN: None     Source Type: Journal    
DOI: 10.2316/Journal.203.2008.4.203-3677     Document Type: Article
Times cited : (11)

References (23)
  • 1
    • 0027836571 scopus 로고
    • The effects of series inductors for flicker reduction in electric power systems supplying arc furnaces
    • Toronto, Canada
    • G.C. Montanari, M. Loggini, L. Pitti, E. Tironi, et al., The effects of series inductors for flicker reduction in electric power systems supplying arc furnaces, Proc. IEEE Industry Applications Society Annual Meeting, Toronto, Canada, 1993, 1496-1503.
    • (1993) Proc. IEEE Industry Applications Society Annual Meeting , pp. 1496-1503
    • Montanari, G.C.1    Loggini, M.2    Pitti, L.3    Tironi, E.4
  • 2
    • 0006017340 scopus 로고
    • Static shunt compensation for voltage flicker reduction and power factor correction
    • Chicago, USA
    • L. Gyugi & A.A. Otto, Static shunt compensation for voltage flicker reduction and power factor correction, Proc. American Power Conf., Chicago, USA, 1976, 1271-1286.
    • (1976) Proc. American Power Conf. , pp. 1271-1286
    • Gyugi, L.1    Otto, A.A.2
  • 6
    • 0032673915 scopus 로고    scopus 로고
    • Field demonstration of a distribution static compensator used to mitigate voltage flicker
    • New York, USA
    • J.R. Clouston & J.H. Gurney, Field demonstration of a distribution static compensator used to mitigate voltage flicker, Proc. IEEE Power Engineering Society Winter Meeting, New York, USA, 1999, 1138-1141.
    • (1999) Proc. IEEE Power Engineering Society Winter Meeting , pp. 1138-1141
    • Clouston, J.R.1    Gurney, J.H.2
  • 7
    • 0029509384 scopus 로고
    • Control system for threephase active power filter which simultaneously compensates power factor and unbalanced loads
    • J.W. Dixon, J.J. Garcia, & L. Moran, Control system for threephase active power filter which simultaneously compensates power factor and unbalanced loads, IEEE Transactions on Industrial Electronics, 42(6), 1995, 636-641.
    • (1995) IEEE Transactions on Industrial Electronics , vol.42 , Issue.6 , pp. 636-641
    • Dixon, J.W.1    Garcia, J.J.2    Moran, L.3
  • 8
    • 0031996526 scopus 로고    scopus 로고
    • Anew control approach to three-phase active filter for harmonics and reactive power compensation
    • B. Singh, K. Al-Haddad, & A. Chandra, Anew control approach to three-phase active filter for harmonics and reactive power compensation, IEEE Transactions on Power Systems, 13(1), 1998, 133-136.
    • (1998) IEEE Transactions on Power Systems , vol.13 , Issue.1 , pp. 133-136
    • Singh, B.1    Al-Haddad, K.2    Chandra, A.3
  • 9
    • 33746362005 scopus 로고    scopus 로고
    • A new control strategy of shunt active filters for power quality improvement of highly and randomly varying loads
    • Ajaccio, France
    • A. Esfandiari, M. Parniani, & H. Mokhtari, A new control strategy of shunt active filters for power quality improvement of highly and randomly varying loads, Proc. 2004 International Symposium on Industrial Electronics, Ajaccio, France, 2004, 1297-1302.
    • (2004) Proc. 2004 International Symposium on Industrial Electronics , pp. 1297-1302
    • Esfandiari, A.1    Parniani, M.2    Mokhtari, H.3
  • 10
    • 0032025040 scopus 로고    scopus 로고
    • The unified power quality conditioner: The integration of series- and shunt-active filters
    • PII S0885899398019462
    • H. Fujita & H.Akagi, The unified power quality conditioner: the integration of series and shunt active filters, IEEE Transactions on Power Electronics, 13(2), 1998, 315-322. (Pubitemid 128742142)
    • (1998) IEEE Transactions on Power Electronics , vol.13 , Issue.2 , pp. 315-322
    • Fujita, H.1    Akagi, H.2
  • 13
    • 84961726918 scopus 로고    scopus 로고
    • Unified power quality conditioner (UPQC): The principle, control and application
    • Osaka, Japan
    • G. Jianjun, X. Dianguo, L. Hankui, & G. Maozhong, Unified power quality conditioner (UPQC): the principle, control and application, Proc. Power Conversion Conf., Osaka, Japan, 2002, 80-85.
    • (2002) Proc. Power Conversion Conf. , pp. 80-85
    • Jianjun, G.1    Dianguo, X.2    Hankui, L.3    Maozhong, G.4
  • 21
    • 0034290033 scopus 로고    scopus 로고
    • Computation of the short-term flicker severity index
    • DOI 10.1109/61.891490
    • T. Keppler, N. Watson, & J. Arrillaga, Computation of the short-term flicker severity index, IEEE Transactions on Power Delivery, 15(4), 2000, 1110-1115. (Pubitemid 32252101)
    • (2000) IEEE Transactions on Power Delivery , vol.15 , Issue.4 , pp. 1110-1115
    • Keppler, T.1    Watson, N.2    Arrillaga, J.3
  • 22
    • 0036814763 scopus 로고    scopus 로고
    • Flicker study using a novel arc furnace model
    • DOI 10.1109/TPWRD.2002.804013
    • O. Ozgun & A. Abur, Flicker study using a novel arc furnace model, IEEE Transactions on Power Delivery, 17(4), 2002, 1158-1163. (Pubitemid 35422453)
    • (2002) IEEE Transactions on Power Delivery , vol.17 , Issue.4 , pp. 1158-1163
    • Ozgun, O.1    Abur, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.