메뉴 건너뛰기




Volumn 2010, Issue , 2010, Pages

Improvement of EEG signal acquisition: An electrical aspect for state of the Art of front end

Author keywords

[No Author keywords available]

Indexed keywords

BIOPOTENTIAL MEASUREMENT; DATA STORING; DESIGN STRATEGIES; EEG SIGNALS; ELECTROENCEPHALOGRAPHIC SIGNALS; ELECTRONIC CIRCUITRY; ELECTRONIC NOISE; ENVIRONMENTAL CONDITIONS; FRONT END; RECORDING ELECTRODES; RECORDING PERFORMANCE; SIGNAL ACQUISITIONS; SIGNAL CONVERSION; STATE OF THE ART; SYSTEM DESIGNERS; SYSTEM ELECTRONICS;

EID: 77951226281     PISSN: 16875265     EISSN: 16875273     Source Type: Journal    
DOI: 10.1155/2010/630649     Document Type: Article
Times cited : (94)

References (24)
  • 3
    • 0028517525 scopus 로고
    • Fundamentals of low-noise analog circuit design
    • Leach M. Jr., Fundamentals of low-noise analog circuit design Proceedings of the IEEE 1994 82 10 1515 1538
    • (1994) Proceedings of the IEEE , vol.82 , Issue.10 , pp. 1515-1538
    • Leach Jr., M.1
  • 6
    • 0035084667 scopus 로고    scopus 로고
    • The five percent electrode system for high-resolution EEG and ERP measurements
    • Oostenveld R., Praamstra P., The five percent electrode system for high-resolution EEG and ERP measurements Clinical Neurophysiology 2001 112 4 713 719
    • (2001) Clinical Neurophysiology , vol.112 , Issue.4 , pp. 713-719
    • Oostenveld, R.1    Praamstra, P.2
  • 7
    • 77953520616 scopus 로고    scopus 로고
    • Biosemi, Product catalog
    • Biosemi,. Product catalog, 2009, http://www.biosemi.com/activeelectrode. htm
    • (2009)
  • 8
    • 77953522946 scopus 로고    scopus 로고
    • Neuroscan Product catalog
    • Neuroscan,. Product catalog, 2009, http://www.neuroscan.com/quickcaps.cfm
    • (2009)
  • 9
    • 77953492488 scopus 로고    scopus 로고
    • Egi Product catalog
    • EGI,. Product catalog, 2009, http://egi.com/research-division-research- products/sensor-nets
    • (2009)
  • 12
    • 0029411942 scopus 로고
    • Multichannel PC-based data-acquisition system for high-resolution EEG
    • Dunseath W. J. R., Kelly E. F., Multichannel PC-based data-acquisition system for high-resolution EEG IEEE Transactions on Biomedical Engineering 1995 42 12 1212 1217
    • (1995) IEEE Transactions on Biomedical Engineering , vol.42 , Issue.12 , pp. 1212-1217
    • Dunseath, W.J.R.1    Kelly, E.F.2
  • 14
    • 0031978722 scopus 로고    scopus 로고
    • A multifunctional helmet for noninvasive neuromonitoring
    • Litscher G., A multifunctional helmet for noninvasive neuromonitoring Journal of Neurosurgical Anesthesiology 1998 10 2 116 119
    • (1998) Journal of Neurosurgical Anesthesiology , vol.10 , Issue.2 , pp. 116-119
    • Litscher, G.1
  • 16
    • 0032125652 scopus 로고    scopus 로고
    • Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex
    • Rousche P. J., Normann R. A., Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex Journal of Neuroscience Methods 1998 82 1 1 15
    • (1998) Journal of Neuroscience Methods , vol.82 , Issue.1 , pp. 1-15
    • Rousche, P.J.1    Normann, R.A.2
  • 17
    • 0020641938 scopus 로고
    • Reduction of interference due to common mode voltage in biopotential amplifiers
    • Winter B. B., Webster J. G., Reduction of interference due to common mode voltage in biopotential amplifiers IEEE Transactions on Biomedical Engineering 1983 30 1 58 62
    • (1983) IEEE Transactions on Biomedical Engineering , vol.30 , Issue.1 , pp. 58-62
    • Winter, B.B.1    Webster, J.G.2
  • 20
    • 0031978722 scopus 로고    scopus 로고
    • A multifunctional helmet for noninvasive neuromonitoring
    • Litscher G., A multifunctional helmet for noninvasive neuromonitoring Journal of Neurosurgical Anesthesiology 1998 10 2 116 119
    • (1998) Journal of Neurosurgical Anesthesiology , vol.10 , Issue.2 , pp. 116-119
    • Litscher, G.1
  • 21
    • 0035970965 scopus 로고    scopus 로고
    • Multiple microelectrode-recording system for human intracortical applications
    • Ulbert I., Halgren E., Heit G., Karmos G., Multiple microelectrode- recording system for human intracortical applications Journal of Neuroscience Methods 2001 106 1 69 79
    • (2001) Journal of Neuroscience Methods , vol.106 , Issue.1 , pp. 69-79
    • Ulbert, I.1    Halgren, E.2    Heit, G.3    Karmos, G.4
  • 23
    • 34247152155 scopus 로고    scopus 로고
    • USB-based 256-channel electroencephalographic data acquisition system for electrical source imaging of the human brain
    • Usakli A. B., Gencer N. G., USB-based 256-channel electroencephalographic data acquisition system for electrical source imaging of the human brain Instrumentation Science Technology 2007 35 3 255 273
    • (2007) Instrumentation Science Technology , vol.35 , Issue.3 , pp. 255-273
    • Usakli, A.B.1    Gencer, N.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.