1
-
-
0016496961
-
15O activation in proton radiation therapy
-
15O activation in proton radiation therapy, Nuc. Instr. Meth., 1975, 125(3), pp. 333-338.
-
(1975)
Nuc. Instr. Meth.
, vol.125
, Issue.3
, pp. 333-338
-
-
Bennett, G.W.1
-
2
-
-
0018224762
-
Visualization and transport of positron emission from proton activation in vivo
-
Bennett G. W. et al, Visualization and transport of positron emission from proton activation in vivo, Science, 1978, 200(4346), pp. 1151-1153.
-
(1978)
Science
, vol.200
, Issue.4346
, pp. 1151-1153
-
-
Bennett, G.W.1
-
3
-
-
34249320889
-
Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy
-
Parodi K. et al, Patient study of in vivo verification of beam delivery and range, using positron emission tomography and computed tomography imaging after proton therapy, J. Radiat. Oncol. Biol. Phys., 2007, 68(3), pp. 920-934.
-
(2007)
J. Radiat. Oncol. Biol. Phys.
, vol.68
, Issue.3
, pp. 920-934
-
-
Parodi, K.1
-
4
-
-
70349582700
-
Systematic analysis of biological and physical limitations of proton beam range verification with offline PET/CT scans
-
Knopf A. et al, Systematic analysis of biological and physical limitations of proton beam range verification with offline PET/CT scans, Phys. Med. Biol., 2009, 54, pp. 4477-4495.
-
(2009)
Phys. Med. Biol.
, vol.54
, pp. 4477-4495
-
-
Knopf, A.1
-
5
-
-
34249684860
-
Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code
-
Parodi K. et al, Clinical CT-based calculations of dose and positron emitter distributions in proton therapy using the FLUKA Monte Carlo code, Phys. Med. Biol., 2007, 52(12), pp. 3369-3387.
-
(2007)
Phys. Med. Biol.
, vol.52
, Issue.12
, pp. 3369-3387
-
-
Parodi, K.1
-
6
-
-
33645541395
-
A filtering approach based on Gaussian-powerlaw convolutions for local PET verification of proton radiotherapy
-
Parodi K. and Bortfeld, T., A filtering approach based on Gaussian-powerlaw convolutions for local PET verification of proton radiotherapy, Phys. Med. Biol., 2006, 51(8), pp. 1991-2009.
-
(2006)
Phys. Med. Biol.
, vol.51
, Issue.8
, pp. 1991-2009
-
-
Parodi, K.1
Bortfeld, T.2
-
8
-
-
0029947707
-
An Analytical Approximation of the Bragg Curve for Therapeutic Proton Beams
-
Bortfeld T., An Analytical Approximation of the Bragg Curve for Therapeutic Proton Beams, Phys. Med. Biol., 1996, 41, 1331-1339.
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 1331-1339
-
-
Bortfeld, T.1
-
9
-
-
44649135081
-
Experimental validation of the filtering approach for dose monitoring in proton therapy at low energy
-
Attanasi F. et al, Experimental validation of the filtering approach for dose monitoring in proton therapy at low energy, Phys. Med., 2008, 24(2), pp. 102-106.
-
(2008)
Phys. Med.
, vol.24
, Issue.2
, pp. 102-106
-
-
Attanasi, F.1
-
10
-
-
60449089438
-
A PET Prototype for In-Beam Monitoring of Proton Therapy
-
Vecchio S. et al, A PET Prototype for In-Beam Monitoring of Proton Therapy, IEEE Transactions on Nuclear Science, 2009, 56(1), pp. 51-56.
-
(2009)
IEEE Transactions on Nuclear Science
, vol.56
, Issue.1
, pp. 51-56
-
-
Vecchio, S.1
-
12
-
-
0031467140
-
An analytical approximation of the Bragg curve for therapeutic proton beams
-
Bortfeld T., An analytical approximation of the Bragg curve for therapeutic proton beams, Med. Phys., 1997, 24, pp. 2024-2033.
-
(1997)
Med. Phys.
, vol.24
, pp. 2024-2033
-
-
Bortfeld, T.1
-
13
-
-
0033983759
-
Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions
-
Schneider W. et al, Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions, Phys. Med. Biol., 2000, 45, pp. 459-478.
-
(2000)
Phys. Med. Biol.
, vol.45
, pp. 459-478
-
-
Schneider, W.1
-
14
-
-
33846585941
-
PET/CT imaging for treatment verification after proton therapy: A study with plastic phantoms and metallic implants
-
Parodi K. et al, PET/CT imaging for treatment verification after proton therapy: a study with plastic phantoms and metallic implants, Med. Phys., 2007a, 34, pp. 419-435.
-
(2007)
Med. Phys.
, vol.34
, pp. 419-435
-
-
Parodi, K.1
-
15
-
-
48349094227
-
Quantitative assessment of the physical potential of proton beam range verification with PET/CT
-
Knopf A. et al, Quantitative assessment of the physical potential of proton beam range verification with PET/CT, Phys. Med. Biol., 2008, 53, pp. 4137-4151.
-
(2008)
Phys. Med. Biol.
, vol.53
, pp. 4137-4151
-
-
Knopf, A.1
|