메뉴 건너뛰기




Volumn 55, Issue 9, 2010, Pages

Implementation of angular response function modeling in SPECT simulations with GATE

Author keywords

[No Author keywords available]

Indexed keywords

ACCELERATION FACTORS; ANGULAR RESPONSE FUNCTIONS; HIGH ENERGY; IODINE-131; MONTE CARLO SIMULATION; NOISE LEVELS; SIEMENS; SIMULATION PLATFORM; SIMULATION RESULT; SIMULATION TIME; SPECT SYSTEM;

EID: 77951188004     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/55/9/N04     Document Type: Article
Times cited : (23)

References (21)
  • 1
    • 0032769798 scopus 로고    scopus 로고
    • Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation
    • Beekman F J, de Jong H W A M and Slijpen E T P 1999 Efficient SPECT scatter calculation in non-uniform media using correlated Monte Carlo simulation Phys. Med. Biol. 44 N183-92
    • (1999) Phys. Med. Biol. , vol.44
    • Beekman, F.J.1    De Jong, H.W.A.M.2    Slijpen, E.T.P.3
  • 4
    • 46149092529 scopus 로고    scopus 로고
    • Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT
    • DOI 10.1118/1.2940159
    • Chen C L, Wang Y, Lee J J and Tsui B M W 2008 Integration of SimSET photon history generator in GATE for efficient Monte Carlo simulations of pinhole SPECT Med. Phys. 35 3278-84 (Pubitemid 351904531)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3278-3284
    • Chen, C.-L.1    Wang, Y.2    Lee, J.J.S.3    Tsui, B.M.W.4
  • 6
    • 0035246203 scopus 로고    scopus 로고
    • Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection
    • de Jong H W A M, Slijpen E T P and Beekman F J 2001 Acceleration of Monte Carlo SPECT simulation using convolution-based forced detection IEEE Trans. Nucl. Sci. 48 58-74
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , pp. 58-74
    • De Jong, H.W.A.M.1    Slijpen, E.T.P.2    Beekman, F.J.3
  • 7
    • 67649145559 scopus 로고    scopus 로고
    • Angular response function parameterization for collimator/detector in SPECT simulations within the GATE toolkit
    • Descourt P, Du Y, Song X, Frey E C, Tsui B M W and Visvikis D 2008 Angular response function parameterization for collimator/detector in SPECT simulations within the GATE toolkit IEEE NSS-MIC Conf. Rec. pp 4969-71
    • (2008) IEEE NSS-MIC Conf. Rec. , pp. 4969-4971
    • Descourt, P.1    Du, Y.2    Song, X.3    Frey, E.C.4    Tsui, B.M.W.5    Visvikis, D.6
  • 8
    • 77951163300 scopus 로고    scopus 로고
    • Acceleration techniques for new detector architecture simulations
    • Descourt P and Visvikis D 2008 Acceleration techniques for new detector architecture simulations J. Nucl. Med. 49 405P
    • (2008) J. Nucl. Med. , vol.49
    • Descourt, P.1    Visvikis, D.2
  • 13
    • 39049144776 scopus 로고    scopus 로고
    • Accelerated SPECT Monte Carlo simulation using multiple projection sampling and convolution-based forced detection
    • DOI 10.1109/TNS.2007.914038
    • Liu S, King M A, Brill A B, Stabin M G and Farncombe T H 2008 Accelerated SPECT Monte Carlo simulation using multiple projection sampling and convolution-based forced detection IEEE Trans. Nucl. Sci. 55 560-7 (Pubitemid 351239513)
    • (2008) IEEE Transactions on Nuclear Science , vol.55 , Issue.1 , pp. 560-567
    • Liu, S.1    King, M.A.2    Brill, A.B.3    Stabin, M.G.4    Farncombe, T.H.5
  • 15
    • 63649158562 scopus 로고    scopus 로고
    • Introducing improved voxel navigation and fictitious interaction tracking in GATE for enhanced efficiency
    • Rehfeld N S, Stute S, Apostolakis J, Soret M and Buvat I 2009 Introducing improved voxel navigation and fictitious interaction tracking in GATE for enhanced efficiency Phys. Med. Biol. 54 2163-78
    • (2009) Phys. Med. Biol. , vol.54 , pp. 2163-2178
    • Rehfeld, N.S.1    Stute, S.2    Apostolakis, J.3    Soret, M.4    Buvat, I.5
  • 16
    • 33745501013 scopus 로고    scopus 로고
    • Fifty years of Monte Carlo simulations for medical physics
    • Rogers D W 2006 Fifty years of Monte Carlo simulations for medical physics Phys. Med. Biol. 51 R287-301
    • (2006) Phys. Med. Biol. , vol.51
    • Rogers, D.W.1
  • 17
    • 22844448366 scopus 로고    scopus 로고
    • Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function
    • DOI 10.1088/0031-9155/50/8/011
    • Song X, Segars W P, Du Y, Tsui B M W and Frey E C 2005 Fast modelling of collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function Phys. Med. Biol. 50 1791-804 (Pubitemid 41223649)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.8 , pp. 1791-1804
    • Song, X.1    Segars, W.P.2    Du, Y.3    Tsui, B.M.W.4    Frey, E.C.5
  • 18
    • 34249063950 scopus 로고    scopus 로고
    • Fast hybrid SPECT simulation including efficient septal penetration modelling (SP-PSF)
    • DOI 10.1088/0031-9155/52/11/007, PII S0031915507390118, 007
    • Staelens S, de Wit T and Beekman F 2007 Fast hybrid SPECT simulation including efficient septal penetration modeling (SP-PSF) Phys. Med. Biol. 52 3027-43 (Pubitemid 46795245)
    • (2007) Physics in Medicine and Biology , vol.52 , Issue.11 , pp. 3027-3043
    • Staelens, S.1    De Wit, T.2    Beekman, F.3
  • 19
    • 0242521407 scopus 로고    scopus 로고
    • Monte Carlo modelling of external radiotherapy photon beams
    • DOI 10.1088/0031-9155/48/21/R01, PII S0031915503332245
    • Verhaegen F and Seuntjens J 2003 Monte Carlo modelling of external radiotherapy photon beams Phys. Med. Biol. 48 R107-64 (Pubitemid 37427947)
    • (2003) Physics in Medicine and Biology , vol.48 , Issue.21
    • Verhaegen, F.1    Seuntjens, J.2
  • 21
    • 0032916211 scopus 로고    scopus 로고
    • Relevance of accurate Monte Carlo modeling in nuclear medical imaging
    • Zaidi H 1999 Relevance of accurate Monte Carlo modeling in nuclear medical imaging Med. Phys. 26 574-608
    • (1999) Med. Phys. , vol.26 , pp. 574-608
    • Zaidi, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.