메뉴 건너뛰기




Volumn 93, Issue 2, 2010, Pages 497-509

Fluoropassivation and gelatin sealing of polyester arterial prostheses to skip preclotting and constrain the chronic inflammatory response

Author keywords

Fluorine; Fluoropassivation; Gelatin; Polyester; Vascular prosthesis

Indexed keywords

BIOLOGICAL ENVIRONMENTS; CHRONIC INFLAMMATORY; CRYSTALLINITIES; FLUORINE CONTENT; FLUOROPASSIVATION; FLUOROPOLYMER; GELATIN COATINGS; IN-VITRO; IN-VIVO; MARGINAL EFFECTS; ORIGINAL MODEL; PET FIBERS; POLYESTER FIBER; POLYESTER VASCULAR PROSTHESIS; VASCULAR PROSTHESIS; WATER PERMEABILITY;

EID: 77951173390     PISSN: 15524973     EISSN: 15524981     Source Type: Journal    
DOI: 10.1002/jbm.b.31609     Document Type: Article
Times cited : (16)

References (76)
  • 1
    • 0037323469 scopus 로고    scopus 로고
    • Biomaterials in the development and future of vascular grafts
    • DOI 10.1067/mva.2003.88
    • Xue L, Greisler HP. Biomaterials in the development and future of vascular grafts. J Vasc Surg 2003;37:472-480. (Pubitemid 36236932)
    • (2003) Journal of Vascular Surgery , vol.37 , Issue.2 , pp. 472-480
    • Xue, L.1    Greisler, H.P.2
  • 4
    • 0000616544 scopus 로고
    • Surgical considerations of aneurysms and atherosclerotic occlusive lesions of the aorta and major arteries
    • Crawford ES, DeBakey ME, Cooley DA, Morris GC Jr. Surgical considerations of aneurysms and atherosclerotic occlusive lesions of the aorta and major arteries. Postgrad Med 1961;29:151-163.
    • (1961) Postgrad Med , vol.29 , pp. 151-163
    • Crawford, E.S.1    DeBakey, M.E.2    Cooley, D.A.3    Morris Jr., G.C.4
  • 5
    • 58249144433 scopus 로고    scopus 로고
    • Atherosclerotic peripheral vascular disease symposium II: Controversies in abdominal aortic aneurysm repair
    • Pearce WH, Zarins CK, Bacharach JM. Atherosclerotic peripheral vascular disease symposium II: Controversies in abdominal aortic aneurysm repair. Circulation 2008;118:2860-2863.
    • (2008) Circulation , vol.118 , pp. 2860-2863
    • Pearce, W.H.1    Zarins, C.K.2    Bacharach, J.M.3
  • 6
    • 0020417560 scopus 로고
    • Coronary by-pass surgery: A reappraisal
    • Freeman Z, Freeman A. Coronary by-pass surgery: A reappraisal. Aust N Z J Med 1982;12:309-320.
    • (1982) Aust N Z J Med , vol.12 , pp. 309-320
    • Freeman, Z.1    Freeman, A.2
  • 9
    • 0030997882 scopus 로고    scopus 로고
    • Remodeling of autologous saphenous vein grafts: The role of perivascular myofibroblasts
    • Shi Y, O'Brien JE, Mannion JD, Morrison RC, Chung W, Fard A, Zalewski A. Remodeling of autologous saphenous vein grafts: The role of perivascular myofibroblasts. Circulation 1997;95: 2684-2693. (Pubitemid 27255498)
    • (1997) Circulation , vol.95 , Issue.12 , pp. 2684-2693
    • Shi, Y.1    O'Brien Jr., J.E.2    Mannion, J.D.3    Morrison, R.C.4    Chung, W.5    Fard, A.6    Zalewski, A.7
  • 10
    • 2342635167 scopus 로고    scopus 로고
    • Allograft replacement for infrarenal aortic graft infection: Early and late results in 179 patients
    • DOI 10.1016/j.jvs.2003.12.040
    • Kieffer E, Gomes D, Chiche L, Fléron M-H, Koskas F, Bahnini A. Allograft replacement for infrarenal aortic graft infection: Early and late results in 179 patients. J Vasc Surg 2004;39:1009-1017. (Pubitemid 38581631)
    • (2004) Journal of Vascular Surgery , vol.39 , Issue.5 , pp. 1009-1017
    • Kieffer, E.1    Gomes, D.2    Chiche, L.3    Fleron, M.-H.4    Koskas, F.5    Bahnini, A.6
  • 13
    • 0024829002 scopus 로고
    • Arterial reconstruction to the foot vessels: Is it worth the trouble?
    • Labbé R, Douville Y, Noël HP. Arterial reconstruction to the foot vessels: Is it worth the trouble? Can J Surg 1989;32:424-427.
    • (1989) Can J Surg , vol.32 , pp. 424-427
    • Labbé, R.1    Douville, Y.2    Noël, H.P.3
  • 15
    • 0024731149 scopus 로고
    • In vivo biostability of four types of arterial grafts with impervious walls: Their haemodynamic and pathological characteristics
    • Charara J, Beaudoin G, Fortin C, Guidoin R, Roy PE, Marble A, Schmitter R, Paynter R. In vivo biostability of four types of arterial grafts with impervious walls: Their haemodynamic and pathological characteristics. J Biomed Eng 1989;11:416-428.
    • (1989) J Biomed Eng , vol.11 , pp. 416-428
    • Charara, J.1    Beaudoin, G.2    Fortin, C.3    Guidoin, R.4    Roy, P.E.5    Marble, A.6    Schmitter, R.7    Paynter, R.8
  • 18
    • 0021246973 scopus 로고
    • COMPLICATIONS EVOLUTIVES ASSOCIEES a L'UTILISATION D'UNE HETEROGREFFE BOVINE COMME ABORD VASCULAIRE
    • Guidoin R, Marois D, Zelter J, Bonnaud P, Marois M, Leblond P, Sheiner N, Gosselin C, Roy P. Progressive complications associated with the use of a bovine heterograft for vascular access. Can J Surg 1984;27:72-77. (Pubitemid 14126644)
    • (1984) Canadian Journal of Surgery , vol.27 , Issue.1 , pp. 72-77
    • Guidoin, R.1    Marois, D.2    Zelter, J.3
  • 19
    • 0021713711 scopus 로고
    • The Sparks-Mandril arterial prosthesis. An ingenious concept, a total failure. What can we learn from it?
    • Guidoin R, Thévenet A, Noël HP, Mary H, Marois MK, Gosselin C, King M. The Sparks-Mandril arterial prosthesis. An ingenious concept, a total failure. What can we learn from it?J Mal Vasc 1984;9: 277-283.
    • (1984) J Mal Vasc , vol.9 , pp. 277-283
    • Guidoin, R.1    Thévenet, A.2    Noël, H.P.3    Mary, H.4    Marois, M.K.5    Gosselin, C.6    King, M.7
  • 21
    • 2642619407 scopus 로고    scopus 로고
    • A completely biological tissue-engineered human blood vessel
    • L'Heureux N, Pâquet S, Labbé R, Germain L, Auger FA. A completely biological tissue-engineered human blood vessel. FASEB J 1998;12:47-56. (Pubitemid 28060270)
    • (1998) FASEB Journal , vol.12 , Issue.1 , pp. 47-56
    • L'Heureux, N.1    Paquet, S.2    Labbe, R.3    Germain, L.4    Auger, F.A.5
  • 22
    • 0018739368 scopus 로고
    • In vivo/in vitro life testing of vascular prostheses
    • Syrett BC, Adrarya A, editors. Philadelphia: ASTM STP 684, American Society for Testing and Materials
    • Botzko K, Synder R, Larkin J, Edwards WS. In vivo/in vitro life testing of vascular prostheses. In: Syrett BC, Adrarya A, editors. Corrosion and Degradation of Implant Materials. Philadelphia: ASTM STP 684, American Society for Testing and Materials;1979. pp 76-88.
    • (1979) Corrosion and Degradation of Implant Materials , pp. 76-88
    • Botzko, K.1    Synder, R.2    Larkin, J.3    Edwards, W.S.4
  • 23
    • 0021716238 scopus 로고
    • Textile Teflon arterial prostheses: How successful are they?
    • Couture J, Guidoin R, King M, Marois M. Textile Teflon arterial prostheses: How successful are they?Can J Surg 1984;27:575-582.
    • (1984) Can J Surg , vol.27 , pp. 575-582
    • Couture, J.1    Guidoin, R.2    King, M.3    Marois, M.4
  • 24
    • 0344518693 scopus 로고
    • Woven knitted and externally supported DacronVR vascular prostheses
    • Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. New York: Grune & Stratton;
    • Synder RW, Botzko KM. Woven knitted and externally supported DacronVR vascular prostheses. In: Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. Biologic and Synthetic Vascular Prostheses. New York: Grune & Stratton; 1982. pp 485-494.
    • (1982) Biologic and Synthetic Vascular Prostheses , pp. 485-494
    • Synder, R.W.1    Botzko, K.M.2
  • 26
    • 0022551292 scopus 로고
    • The initial blood retention properties of arterial prostheses
    • Legendre JM, de la Faye D, Guidoin R, King M, Lefevre C, Gosselin C. The initial blood retention properties of arterial prostheses. Res Exp Med 1986;186:185-202. (Pubitemid 16088512)
    • (1986) Research in Experimental Medicine , vol.186 , Issue.3 , pp. 185-202
    • Legendre, J.M.1    De La Faye, D.2    Guidoin, R.3
  • 28
    • 0021281224 scopus 로고
    • Albumin coating of a knitted polyester arterial prosthesis: An alternative to preclotting
    • Guidoin R, Synder R, Martin L, Botzko K, Marois M, Awad J, King M, Domurado D, Bedros M, Gosselin C. Albumin coating of a knitted polyester arterial prosthesis: An alternative to preclotting. Ann Thorac Surg 1984;37:457-465. (Pubitemid 14077463)
    • (1984) Annals of Thoracic Surgery , vol.37 , Issue.6 , pp. 457-465
    • Guidoin, R.1    Snyder, R.2    Martin, L.3
  • 29
    • 0030899355 scopus 로고    scopus 로고
    • The Dialine II graft: A new collagen-impregnated warp-knitted polyester arterial prosthesis
    • DOI 10.1007/s100169900023
    • Marois Y, Guidoin R, Couture J, King MW, Martin L, Roy R. The Dialine II graft: A new collagen-impregnated warp-knitted polyester arterial prosthesis. Ann Vasc Surg 1997;11:133-140. (Pubitemid 27164352)
    • (1997) Annals of Vascular Surgery , vol.11 , Issue.2 , pp. 133-140
    • Marais, Y.1    Guidoin, R.2    Deng, X.3    King, M.W.4    Martin, L.5    Roy, R.6
  • 31
    • 0024510310 scopus 로고
    • Collagen coatings as biological sealants for textile arterial prostheses
    • DOI 10.1016/0142-9612(89)90018-5
    • Guidoin R, Marceau D, Couture J, Rao TJ, Merhi Y, Roy PE, DeLa- Faye D. Collagen coatings as biological sealants for textile arterial prostheses. Biomaterials 1989;10:156-165. (Pubitemid 19120669)
    • (1989) Biomaterials , vol.10 , Issue.3 , pp. 156-165
    • Guidoin, R.1    Marceau, D.2    Couture, J.3    Raomerhi, T.J.Y.4    Roy, P.-E.5    De La Faye, D.6
  • 33
    • 0024262842 scopus 로고
    • Fate of polyester arterial prostheses implanted as thoraco-abdominal by-passes in dogs: Haematology, pathology, and biochemistry
    • Merhi Y, Guidoin R, Forest JC. Fate of polyester arterial prostheses implanted as thoraco-abdominal by-passes in dogs: Haematology, pathology, and biochemistry. Clin Invest Med 1988;11: 403-416. (Pubitemid 19011515)
    • (1988) Clinical and Investigative Medicine , vol.11 , Issue.6 , pp. 403-416
    • Merhi, Y.1    Guidoin, R.2    Forest, J.-C.3
  • 34
    • 0034028083 scopus 로고    scopus 로고
    • Alternative blood conduits: Assessment of whether the porosity of synthetic prostheses is the key to long-term biofunctionality
    • Deng X, Guidoin R. Alternative blood conduits: Assessment of whether the porosity of synthetic prostheses is the key to longterm biofunctionality. Med Biol Eng Comput 2000;38:219-225. (Pubitemid 30192998)
    • (2000) Medical and Biological Engineering and Computing , vol.38 , Issue.2 , pp. 219-225
    • Deng, X.1    Guidoin, R.2
  • 36
    • 0018384589 scopus 로고
    • Relation between fibrinolytic activity and prostacyclin generation of atherosclerotic artery and dacron prosthetic graft
    • DOI 10.1007/BF01968247
    • Sinzinger H, Silberbauer K, Winter M, Auerswald W. Relation between fibrinolytic activity and prostacyclin generation of atherosclerotic artery and Dacron prosthetic graft. Experientia 1979;35: 785-786. (Pubitemid 9193898)
    • (1979) Experientia , vol.35 , Issue.6 , pp. 785-786
    • Sinzinger, H.1    Silberbauer, K.2    Winter, M.3    Auerswald, W.4
  • 37
    • 0020645459 scopus 로고
    • 2 balance: Pathophysiological and therapeutic implications
    • Bunting S, Moncada S, Vane JR. The prostacyclin-thromboxane- A2 balance: Pathophysiological and therapeutic implications. Br Med Bull 1983;39:271-276. (Pubitemid 13063958)
    • (1983) British Medical Bulletin , vol.39 , Issue.3 , pp. 271-276
    • Bunting, S.1    Moncada, S.2    Vane, J.R.3
  • 40
    • 30444439216 scopus 로고    scopus 로고
    • The discovery of nitric oxide and its role in vascular biology
    • Moncada S, Higgs EA. The discovery of nitric oxide and its role in vascular biology. Br J Pharmacol 2006;147 (Suppl 1):S193-S201.
    • (2006) Br J Pharmacol , vol.147 , Issue.SUPPL. 1
    • Moncada, S.1    Higgs, E.A.2
  • 41
    • 0015260173 scopus 로고
    • Healing of arterial prostheses in man: Its incompleteness
    • Berger K, Sauvage LR, Rao AM, Wood SJ. Healing of arterial prostheses in man: Its incompleteness. Ann Surg 1972;175:118-127.
    • (1972) Ann Surg , vol.175 , pp. 118-127
    • Berger, K.1    Sauvage, L.R.2    Rao, A.M.3    Wood, S.J.4
  • 42
    • 0029042925 scopus 로고
    • Acute thrombogenicity of arterial prostheses exposed to reduced blood-flow in dogs: Effects of heparin, aspirin, and prostacyclin
    • Merhi Y, Bernier J, Marois Y, Guidoin R. Acute thrombogenicity of arterial prostheses exposed to reduced blood-flow in dogs: Effects of heparin, aspirin, and prostacyclin. J Cardiovasc Pharmacol 1995;26:1-5.
    • (1995) J Cardiovasc Pharmacol , vol.26 , pp. 1-5
    • Merhi, Y.1    Bernier, J.2    Marois, Y.3    Guidoin, R.4
  • 43
    • 0002561056 scopus 로고
    • A biological and structural evaluation of retrieved Dacron aterial prostheses
    • Weinstein A, Gibbon D, Brown S, Ruff W, editors. Washington DC: NBS Special Publication 601, National Bureau of Standards; sp601
    • Guidoin R, King M, Blais P, Marois M, Gosselin C, Roy P, Courbier R, David M, Noël HP. A biological and structural evaluation of retrieved Dacron aterial prostheses. In: Weinstein A, Gibbon D, Brown S, Ruff W, editors. Implant Retrieval: Material and Biological Analysis. Washington DC: NBS Special Publication 601, National Bureau of Standards; 1981. pp 29-129; sp601.
    • (1981) Implant Retrieval: Material and Biological Analysis , pp. 29-129
    • Guidoin, R.1    King, M.2    Blais, P.3    Marois, M.4    Gosselin, C.5    Roy, P.6    Courbier, R.7    David, M.8    Noël, H.P.9
  • 45
    • 0001328326 scopus 로고
    • Physical characteristics of expanded polytetrafluoroethylene grafts
    • Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. New York: Grune & Stratton;
    • Boyce B. Physical characteristics of expanded polytetrafluoroethylene grafts. In: Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. Biologic and Synthetic Vascular Prostheses. New York: Grune & Stratton;1982. pp 553-561.
    • (1982) Biologic and Synthetic Vascular Prostheses , pp. 553-561
    • Boyce, B.1
  • 46
    • 0017887364 scopus 로고
    • Evaluation of the thrombogenic potential of three types of arterial graft studied in an artificial circulation
    • Hamlin GW, Rajah SM, Crow MJ, Kester RC. Evaluation of the thrombogenic potential of three types of arterial graft studied in an artificial circulation. Br J Surg 1978;65:272-276.
    • (1978) Br J Surg , vol.65 , pp. 272-276
    • Hamlin, G.W.1    Rajah, S.M.2    Crow, M.J.3    Kester, R.C.4
  • 48
    • 23144434711 scopus 로고
    • Expanded polytetrafluoroethylene vascular grafts: Clinical and experimental observations
    • Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. New York: Grune & Stratton;
    • Graham LM, Bergan JJ. Expanded polytetrafluoroethylene vascular grafts: Clinical and experimental observations. In: Stanley JC, Burkel WE, Lindenauer SM, Bartlett RH, Turcotte JG, editors. Biologic and Synthetic Vascular Prostheses. New York: Grune & Stratton;1982. pp 563-586.
    • (1982) Biologic and Synthetic Vascular Prostheses , pp. 563-586
    • Graham, L.M.1    Bergan, J.J.2
  • 50
    • 77951156021 scopus 로고
    • Fluorinating polymer surfaces
    • US Patent No.5,356,668
    • Paton DM, Ashton TR, Maini R. Fluorinating polymer surfaces. US Patent No.5,356,668,1994.
    • (1994)
    • Paton, D.M.1    Ashton, T.R.2    Maini, R.3
  • 51
    • 0030497641 scopus 로고    scopus 로고
    • Experimental evaluation of bleeding complications, thrombogenicity and neointimal characteristics of prosthetic patch materials used for carotid angioplasty
    • DOI 10.1016/S0967-2109(96)00044-0, PII S0967210996000440
    • Rhee RY, Gloviczki P, Cambria RA, Miller VM. Experimental evaluation of bleeding complications, thrombogenicity and neointimal characteristics of prosthetic patch materials used for carotid angioplasty. Cardiovasc Surg 1996;4:746-752. (Pubitemid 27061903)
    • (1996) Cardiovascular Surgery , vol.4 , Issue.6 , pp. 746-752
    • Rhee, R.Y.1    Gloviczki, P.2    Cambria, R.A.3    Miller, V.M.4
  • 53
    • 0032792598 scopus 로고    scopus 로고
    • In vivo biocompatibility and degradation studies of polyhydroxyoctanoate in the rat: A new sealant for the polyester arterial prosthesis
    • Marois Y, Zhang Z, Vert M, Beaulieu L, Lenz RW, Guidoin R. In vivo biocompatibility and degradation studies of polyhydroxyoctanoate in the rat: A new sealant for the polyester arterial prosthesis. Tissue Eng 1999;5:369-386.
    • (1999) Tissue Eng , vol.5 , pp. 369-386
    • Marois, Y.1    Zhang, Z.2    Vert, M.3    Beaulieu, L.4    Lenz, R.W.5    Guidoin, R.6
  • 54
    • 45749086053 scopus 로고    scopus 로고
    • Prospective Randomized Study of Carotid Endarterectomy with Fluoropassiv Thin Wall Carotid Patch versus Venous Patch
    • DOI 10.1016/j.ejvs.2008.02.009, PII S1078588408001226
    • Meerwaldt R, Lansink KWW, Blomme AM, Fritschy WM. Prospective randomized study of carotid endarterectomy with fluoropassiv TM thin wall carotid patch versus venous patch. Eur J Vasc Endovasc Surg 2008;36:45-52. (Pubitemid 351876161)
    • (2008) European Journal of Vascular and Endovascular Surgery , vol.36 , Issue.1 , pp. 45-52
    • Meerwaldt, R.1    Lansink, K.W.W.2    Blomme, A.M.3    Fritschy, W.M.4
  • 55
    • 0028464968 scopus 로고
    • The benefits of fluoropassivation of polyester arterial prostheses as observed in a canine model
    • Guidoin R, Marois Y, Zhang Z, King M, Martin L, Laroche G, Awad J. The benefits of fluoropassivation of polyester arterial prostheses as observed in a canine model. ASAIO J 1994;40: M870-M879. (Pubitemid 24364325)
    • (1994) ASAIO Journal , vol.40 , Issue.3
    • Guidoin, R.1    Marois, Y.2    Zhang, Z.3    King, M.4    Martin, L.5    Laroche, G.6    Awad, J.7
  • 59
    • 0029256637 scopus 로고
    • Removing fresh tissue from explanted polyurethane prostheses: Which approach facilitates physico-chemical analysis?
    • Zhang Z, Guidoin R, King MW, How TV, Marois Y, Laroche G. Removing fresh tissue from explanted polyurethane prostheses: Which approach facilitates physico-chemical analysis?Biomaterials 1995;16:369-380.
    • (1995) Biomaterials , vol.16 , pp. 369-380
    • Zhang, Z.1    Guidoin, R.2    King, M.W.3    How, T.V.4    Marois, Y.5    Laroche, G.6
  • 60
    • 0028455044 scopus 로고
    • Morphological, physical and chemical evaluation of the Vascugraft® arterial prosthesis: Comparison of a novel polyurethane device with other microporous structures
    • DOI 10.1016/0142-9612(94)90014-0
    • Zhang Z, King M, Guidoin R, Therrien M, Pezolet M, Adnot A, Ukpabi P, Vantal MH. Morphological, physical and chemical evaluation of the Vascugraft® arterial prosthesis: Comparison of a novel polyurethane device with other microporous structures. Biomaterials 1994;15:483-501. (Pubitemid 24180616)
    • (1994) Biomaterials , vol.15 , Issue.7 , pp. 483-501
    • Zhang, Z.1    King, M.W.2    Guidoin, R.3    Therrien, M.4    Pezolet, M.5    Adnot, A.6    Ukpabi, P.7    Vantal, M.H.8
  • 62
    • 1542738701 scopus 로고    scopus 로고
    • ANSI/AAMI/ ISO 7198 1998-2001, Arlington, VA, Association for the Advancement of Medical Instrumentation
    • Cardiovascular implants-Tubular vascular prostheses. ANSI/AAMI/ ISO 7198 1998-2001, Arlington, VA, Association for the Advancement of Medical Instrumentation,1998.
    • (1998) Cardiovascular Implants-Tubular Vascular Prostheses
  • 63
    • 0017936060 scopus 로고
    • EQUILIBRIUM MELTING PARAMETERS of POLY(ETHYLENE TEREPHTHALATE)
    • Mehta A, Gaur U, Wunderlich B. Equilibrium melting parameters of poly(ethylene terephthalate). J Polym Sci Polym Phys Ed 1978; 16:289-296. (Pubitemid 8576743)
    • (1978) J Polym Sci Polym Phys Ed , vol.16 , Issue.2 , pp. 289-296
    • Mehta, A.1    Gaur, U.2    Wunderlich, B.3
  • 64
    • 0028533689 scopus 로고
    • In vitro exposure of a novel polyesterurethane graft to enzymes: A study of the biostability of the VascugraftVR arterial prosthesis
    • Zhang Z, King M, Guidoin R, Therrien M, Doillon C, Diehl-Jones WL, Huebner E. In vitro exposure of a novel polyesterurethane graft to enzymes: A study of the biostability of the VascugraftVR arterial prosthesis. Biomaterials 1994;15:1129-1144.
    • (1994) Biomaterials , vol.15 , pp. 1129-1144
    • Zhang, Z.1    King, M.2    Guidoin, R.3    Therrien, M.4    Doillon, C.5    Diehl-Jones, W.L.6    Huebner, E.7
  • 65
    • 0017956637 scopus 로고
    • Applications of ESCA to polymer chemistry. XVII. Systematic investigation of the core levels of simple homopolymers
    • Clark DT, Thomas HR. Applications of ESCA to polymer chemistry. XVII. Systematic investigation of the core levels of simple homopolymers. J Polym Sci Polym Chem Ed 1978;16:791-820.
    • (1978) J Polym Sci Polym Chem Ed , vol.16 , pp. 791-820
    • Clark, D.T.1    Thomas, H.R.2
  • 66
    • 0015586430 scopus 로고
    • Application of ESCA to polymer chemistry. III. Structures and bonding in homopolymers of ethylene and the fluoroethylenes and determination of the compostions of fluoro copolymers
    • Clark DT, Feast WJ, Kilcast D, Musgrave WKR. Application of ESCA to polymer chemistry. III. Structures and bonding in homopolymers of ethylene and the fluoroethylenes and determination of the compostions of fluoro copolymers. J Polym Sci Poly Chem Ed 1973;11:389-411.
    • (1973) J Polym Sci Poly Chem Ed , vol.11 , pp. 389-411
    • Clark, D.T.1    Feast, W.J.2    Kilcast, D.3    Musgrave, W.K.R.4
  • 67
    • 0027887627 scopus 로고
    • Decomposition of fluorinated diethers on the clean iron surface
    • Napier ME, Stair PC. Decomposition of fluorinated diethers on the clean iron surface. Surf Sci 1993;298:201-214.
    • (1993) Surf Sci , vol.298 , pp. 201-214
    • Napier, M.E.1    Stair, P.C.2
  • 68
    • 0028496477 scopus 로고
    • Decomposition of perfluoro-1-methoxy-2-ethoxy ethane on iron surfaces chemically modified with oxygen
    • Napier ME, Stair PC. Decomposition of perfluoro-1-methoxy-2-ethoxy ethane on iron surfaces chemically modified with oxygen. Surf Sci 1994;316:317-328.
    • (1994) Surf Sci , vol.316 , pp. 317-328
    • Napier, M.E.1    Stair, P.C.2
  • 69
    • 33748469869 scopus 로고    scopus 로고
    • Arteries, veins and lymphatic vessels
    • Black J, Hastings G, editors. London: Chapman & Hall;
    • Deng X, Guidoin R. Arteries, veins and lymphatic vessels. In: Black J, Hastings G, editors. Handbook of Biomaterial Properties. London: Chapman & Hall; 1998. pp 81-105.
    • (1998) Handbook of Biomaterial Properties , pp. 81-105
    • Deng, X.1    Guidoin, R.2
  • 71
    • 0001829540 scopus 로고
    • Physical constants of poly(oxyethyleneoxyterephthaloyl) (poly(ethylene terephthalate))
    • 3rd edition, Brandrup J, Immergut EH, editors. New York: John Wiley & Sons;
    • Lawton EL, Ringwald EL. Physical constants of poly(oxyethyleneoxyterephthaloyl) (poly(ethylene terephthalate)). In: Polymer Handbook, 3rd edition, Brandrup J, Immergut EH, editors. New York: John Wiley & Sons; 1989, pp 101-106.
    • (1989) Polymer Handbook , pp. 101-106
    • Lawton, E.L.1    Ringwald, E.L.2
  • 72
    • 0026416648 scopus 로고
    • Properties of PET fibers with high modulus and low shrinkage (HMLS). I. Yarn properties and morphology
    • Rim PB, Nelson CJ. Properties of PET fibers with high modulus and low shrinkage (HMLS). I. Yarn properties and morphology. J Appl Polym Sci 1991;42:1807-1813.
    • (1991) J Appl Polym Sci , vol.42 , pp. 1807-1813
    • Rim, P.B.1    Nelson, C.J.2
  • 73
    • 0343838716 scopus 로고
    • Plasma gas discharge treatment for improving the compatibility of biomaterials
    • US Patent No.5,034,265
    • Hoffman AS, Garfinkle AM, Ratner BD, Hanson SR. Plasma gas discharge treatment for improving the compatibility of biomaterials. US Patent No.5,034,265,1991.
    • (1991)
    • Hoffman, A.S.1    Garfinkle, A.M.2    Ratner, B.D.3    Hanson, S.R.4
  • 74
    • 77951190782 scopus 로고
    • Etude morphométrique de la cicatrisation d'une prothèse artérielle en polyester traitée avec un plasma de fluoroéthylène et implantée chez le chien
    • Lafrenière-Gagnon D, Guidoin R, Roy PE, Martin L, Douville Y, Bernard PM. Etude morphométrique de la cicatrisation d'une prothèse artérielle en polyester traitée avec un plasma de fluoroéthylène et implantée chez le chien. Rev Europ Technol Biomed 1990;11:300-309.
    • (1990) Rev Europ Technol Biomed , vol.11 , pp. 300-309
    • Lafrenière-Gagnon, D.1    Guidoin, R.2    Roy, P.E.3    Martin, L.4    Douville, Y.5    Bernard, P.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.