-
1
-
-
23844554858
-
Attenuation correction for the NIH ATLAS small animal PET scanner
-
DOI 10.1109/TNS.2005.851467
-
R. Yao, J. Seidel, J.-S. Liow, and M. V. Green, "Attenuation correction for the NIH ATLAS small animal PET scanner.," IEEE Trans Nucl Sci, vol. 52, pp. 664-668, 2005. (Pubitemid 41172557)
-
(2005)
IEEE Transactions on Nuclear Science
, vol.52
, Issue.3 I
, pp. 664-668
-
-
Yao, R.1
Seidel, J.2
Liow, J.-S.3
Green, M.V.4
-
2
-
-
22844452107
-
Attenuation correction for small animal PET tomographs
-
Apr 21
-
P. L. Chow, F. R. Rannou, and A. F. Chatziioannou, "Attenuation correction for small animal PET tomographs.," Phys Med Biol, vol. 50, pp. 1837-1850, Apr 21 2005.
-
(2005)
Phys Med Biol
, vol.50
, pp. 1837-1850
-
-
Chow, P.L.1
Rannou, F.R.2
Chatziioannou, A.F.3
-
3
-
-
52449084002
-
Advances in attenuation correction techniques in PET
-
H. Zaidi, M-L. Montandon, A. Alavi, "Advances in attenuation correction techniques in PET," PET Clin. vol. 2, pp. 191-217, 2007.
-
(2007)
PET Clin.
, vol.2
, pp. 191-217
-
-
Zaidi, H.1
Montandon, M.-L.2
Alavi, A.3
-
4
-
-
48349113187
-
Experimental evaluation of the bilinear transformation used in the CT-based attenuation correction for small animal PET imaging
-
J. Yu, J. Seidel, M. Pomper, and B. M. W. Tsui, "Experimental evaluation of the bilinear transformation used in the CT-based attenuation correction for small animal PET imaging," in Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE, 2007, pp. 3747-3750.
-
Nuclear Science Symposium Conference Record, 2007. NSS '07. IEEE, 2007
, pp. 3747-3750
-
-
Yu, J.1
Seidel, J.2
Pomper, M.3
Tsui, B.M.W.4
-
5
-
-
0029239374
-
The use of X-ray CT for attenuation correction of PET data
-
T. Beyer, P. E. Kinahan, D. W. Townsend, and D. Sashin, "The use of X-ray CT for attenuation correction of PET data," in Proc. IEEE Nuclear Science Symposium and Medical Imaging Conference, 30 Oct.-5 Nov., Norfolk, VA, USA, 1994, pp. 1573-1577.
-
Proc. IEEE Nuclear Science Symposium and Medical Imaging Conference, 30 Oct.-5 Nov., Norfolk, VA, USA, 1994
, pp. 1573-1577
-
-
Beyer, T.1
Kinahan, P.E.2
Townsend, D.W.3
Sashin, D.4
-
6
-
-
0037811001
-
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
-
Jul
-
P. E. Kinahan, B. H. Hasegawa, and T. Beyer, "X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.," Semin Nucl Med, vol. 33, pp. 166-179, Jul 2003.
-
(2003)
Semin Nucl Med
, vol.33
, pp. 166-179
-
-
Kinahan, P.E.1
Hasegawa, B.H.2
Beyer, T.3
-
7
-
-
0031791001
-
Attenuation correction for a combined 3D PET/CT scanner
-
Oct
-
P. E. Kinahan, D. W. Townsend, T. Beyer, and D. Sashin, "Attenuation correction for a combined 3D PET/CT scanner.," Med Phys, vol. 25, pp. 2046-2053, Oct 1998.
-
(1998)
Med Phys
, vol.25
, pp. 2046-2053
-
-
Kinahan, P.E.1
Townsend, D.W.2
Beyer, T.3
Sashin, D.4
-
8
-
-
0142094995
-
A generalized model for the conversion from CT numbers to linear attenuation coefficients
-
C. Bai, L. Shao, A. J. Da Silva, and Z. Zhao, "A generalized model for the conversion from CT numbers to linear attenuation coefficients.," IEEE Trans Nucl Sci, vol. 50, pp. 1510-1515, 2003.
-
(2003)
IEEE Trans Nucl Sci
, vol.50
, pp. 1510-1515
-
-
Bai, C.1
Shao, L.2
Da Silva, A.J.3
Zhao, Z.4
-
9
-
-
70350623135
-
Comparative assessment of different energy mapping approaches in CT based attenuation correction: A patient study
-
J. Vander Sloten PV, M. Nyssen, J. Haueisen, Eds, Antwerp, Belgium, 23-27 November 2008: Springer
-
M. Shirmohammad, M. Ay, A. Rahmim, S. Sarkar, H. Zaidi, "Comparative assessment of different energy mapping approaches in CT based attenuation correction: a patient study," IFMBE Proceedings. J. Vander Sloten PV, M. Nyssen, J. Haueisen, Eds, Antwerp, Belgium, 23-27 November 2008: Springer; 2008; pp 496-499.
-
(2008)
IFMBE Proceedings
, pp. 496-499
-
-
Shirmohammad, M.1
Ay, M.2
Rahmim, A.3
Sarkar, S.4
Zaidi, H.5
-
10
-
-
0003966102
-
-
Gaithersburg: Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899
-
M. J. Berger, J. H. Hubbell, S. M. Seltzer, J. Chang, J. S. Coursey, R. Sukumar, and D. S. Zucker, "XCOM: photon cross sections database. Report NBSIR 87-3597" Gaithersburg: Ionizing Radiation Division, Physics Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899.
-
XCOM: Photon Cross Sections Database. Report NBSIR 87-3597
-
-
Berger, M.J.1
Hubbell, J.H.2
Seltzer, S.M.3
Chang, J.4
Coursey, J.S.5
Sukumar, R.6
Zucker, D.S.7
|