Volumn 5, Issue , 2007, Pages 3747-3750

Experimental evaluation of the bilinear transformation used in the CT-based attenuation correction for small animal PET imaging

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD; CLUSTERING ALGORITHMS; COMPUTERIZED TOMOGRAPHY; ELECTRIC INSTRUMENT TRANSFORMERS; GERMANIUM; HISTOLOGY; IMAGE ENHANCEMENT; OPTICAL PROJECTORS; POSITRON EMISSION TOMOGRAPHY; SPHERES;

EID: 48349113187     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2007.4436937     Document Type: Conference Paper
Times cited : (4)

References (9)
  • 1
    • 22844452107 scopus 로고    scopus 로고
    • Attenuation correction for small animal PET tomographs
    • Patrick L. Chow, Fernando R. Rannou, and Arion F. Chatziioannou, "Attenuation correction for small animal PET tomographs", Phys. Med. Biol. vol. 50, pp.1837-1855, 2005.
    • (2005) Phys. Med. Biol , vol.50 , pp. 1837-1855
    • Chow, P.L.1    Rannou, F.R.2    Chatziioannou, A.F.3
  • 2
    • 0037315301 scopus 로고    scopus 로고
    • Determination of the attenuation map in emission tomography
    • Zaidi H and Hasegawa B, "Determination of the attenuation map in emission tomography" J. Nucl. Med. vol. 44, pp. 291-315, 2003.
    • (2003) J. Nucl. Med , vol.44 , pp. 291-315
    • Zaidi, H.1    Hasegawa, B.2
  • 3
    • 0037811001 scopus 로고    scopus 로고
    • X-Ray-Based Attenuation Correction for PET/CT Scanners
    • July, pp
    • Paul E. Kinahan, Bruce H. Hasegawa, and Thomas Beyer, "X-Ray-Based Attenuation Correction for PET/CT Scanners". Seminars in Nuclear Medicine, Vol. XXXIII, No 3 (July), pp 166-179, 2003.
    • (2003) Seminars in Nuclear Medicine , vol.33 , Issue.3 , pp. 166-179
    • Kinahan, P.E.1    Hasegawa, B.H.2    Beyer, T.3
  • 4
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Kinahan P E, Townsend DW, Beyer T and Sashin D, "Attenuation correction for a combined 3D PET/CT scanner". Med. Phys. 25 2046-53, 1998.
    • (1998) Med. Phys , vol.25 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 5
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • C. Burger, G. Goerres, S. Schoenes. PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur J Nucl Med, vol. 29, pp. 922-927, 2002.
    • (2002) Eur J Nucl Med , vol.29 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3
  • 6
    • 34447335331 scopus 로고    scopus 로고
    • Effective Methods to Correct Contrast Agent-Induced Errors in PET Quantification in Cardiac PET/CT
    • Florian Buther, et al. "Effective Methods to Correct Contrast Agent-Induced Errors in PET Quantification in Cardiac PET/CT", J Nucl Med vol. 48, pp. 1060-68, 2007.
    • (2007) J Nucl Med , vol.48 , pp. 1060-1068
    • Buther, F.1
  • 7
    • 0037783428 scopus 로고    scopus 로고
    • CT-based attenuation correction in the calculation of semiquantitative indices of [18F]FDG PET uptake in PET
    • Visvikis D, Costa DC, Croasdale I, Lonn AHR, Bomanji J, Gacinovic S, Il PJ. CT-based attenuation correction in the calculation of semiquantitative indices of [18F]FDG PET uptake in PET. Eur J Nucl Med; vol. 30, pp. 344-353. 2003.
    • (2003) Eur J Nucl Med , vol.30 , pp. 344-353
    • Visvikis, D.1    Costa, D.C.2    Croasdale, I.3    Lonn, A.H.R.4    Bomanji, J.5    Gacinovic, S.6    Il, P.J.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.