메뉴 건너뛰기




Volumn , Issue , 2009, Pages 2896-2901

A methodology for optimizing the acquisition time of a clinical PET scan using GATE

Author keywords

[No Author keywords available]

Indexed keywords

ACQUISITION TIME; BODY SIZES; COUNTING RATES; CRITICAL PARAMETER; DEADTIME; DIFFERENT SIZES; DOSE RANGE; ENERGY WINDOWS; IMAGING PROTOCOL; LOW DOSE; MOTION ARTIFACT; NOISE EQUIVALENT COUNT RATES; NOISE EQUIVALENT COUNTS; OPTIMIZATION METHODOLOGY; PEAK VALUES; PET SCAN; PET/CT SCANNERS; PROJECTION DATA; RATE PERFORMANCE; SCANNER SYSTEMS; SCANNING TIME; SIMULATION PACKAGES; SIMULATION STUDIES; STATISTICAL QUALITY; TIME WINDOWS;

EID: 77951154463     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2009.5401619     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 1
    • 33644828174 scopus 로고    scopus 로고
    • Optimizing injected dose in clinical PET by accurately modelling the Counting-Rate response functions specific to individual patient scans
    • Nov
    • Watson CC, Casey M, Bendriem B, Carney J, Townsend D, Eberl L., Meikle S., DiFilippo F. "Optimizing injected dose in clinical PET by accurately modelling the Counting-Rate response functions specific to individual patient scans", The journal of nuclear medicine, vol 46, no 11, Nov 2005
    • (2005) The Journal of Nuclear Medicine , vol.46 , Issue.11
    • Watson, C.C.1    Casey, M.2    Bendriem, B.3    Carney, J.4    Townsend, D.5    Eberl, L.6    Meikle, S.7    Difilippo, F.8
  • 2
    • 0026219522 scopus 로고
    • Noise equivalent count measurements in a neuro-PET scanner with retractable septa
    • Bailey DL, Jones T., Spinks TJ, et al, "Noise equivalent count measurements in a neuro-PET scanner with retractable septa", IEEE Trans Med Imaging, 1991;10:p256-260
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 256-260
    • Bailey, D.L.1    Jones, T.2    Spinks, T.J.3
  • 4
    • 0029849910 scopus 로고    scopus 로고
    • Optimization of noise-equivalent count rates in 3D PET
    • Badawi RD, Marsden PK, Cronin BF, et al, "Optimization of noise-equivalent count rates in 3D PET", Phys Med Biol. 1996;41:p1755-1776
    • (1996) Phys Med Biol , vol.41 , pp. 1755-1776
    • Badawi, R.D.1    Marsden, P.K.2    Cronin, B.F.3
  • 5
    • 0036731951 scopus 로고    scopus 로고
    • Optimization of injected dose based on noise equivalent count rates for 2- And 3-dimensional whole-body PET
    • Lartizien C, Comtat C., Kinahan PE, et al, "Optimization of injected dose based on noise equivalent count rates for 2- and 3-dimensional whole-body PET", Journal of Nuclear Medicine 2002;43:p1268-1278
    • (2002) Journal of Nuclear Medicine , vol.43 , pp. 1268-1278
    • Lartizien, C.1    Comtat, C.2    Kinahan, P.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.