메뉴 건너뛰기




Volumn 18, Issue 12, 2007, Pages 1277-1281

Safety of single transseptal puncture for ablation of atrial fibrillation: Retrospective study from a large cohort of patients

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ARTICLE; CATHETER; CATHETER ABLATION; COHORT ANALYSIS; FEMALE; FOLLOW UP; HEART ATRIUM FIBRILLATION; HEART ATRIUM SEPTUM DEFECT; HEART LEFT ATRIUM; HUMAN; MAJOR CLINICAL STUDY; MALE; MORBIDITY; PRIORITY JOURNAL; PULMONARY VEIN; PUNCTURE; RETROSPECTIVE STUDY; SAFETY; TRANSSEPTAL PUNCTURE;

EID: 36148963732     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/j.1540-8167.2007.00958.x     Document Type: Article
Times cited : (60)

References (21)
  • 1
    • 0000556337 scopus 로고
    • Transseptal left atrial puncture: New technique for measurement of left atrial pressure in man
    • Ross J, Braunwald E, Morrow AG : Transseptal left atrial puncture: New technique for measurement of left atrial pressure in man. Am J Cardiol 1959 3 : 653 655.
    • (1959) Am J Cardiol , vol.3 , pp. 653-655
    • Ross, J.1    Braunwald, E.2    Morrow, A.G.3
  • 2
    • 0035038785 scopus 로고    scopus 로고
    • Trans-septal left heart catheterization for cardiac ablation procedures
    • Gonzales MD, Otomo K, Shah N, et al : Trans-septal left heart catheterization for cardiac ablation procedures. J Interv Card Electrophysiol 2001 5 : 89 95.
    • (2001) J Interv Card Electrophysiol , vol.5 , pp. 89-95
    • Gonzales, M.D.1    Otomo, K.2    Shah, N.3
  • 3
    • 0035035451 scopus 로고    scopus 로고
    • Electrophysiologic characteristics in initiation of paroxysmal atrial fibrillation from a focal area
    • Lu TM, Tai CT, Hsieh MH, et al : Electrophysiologic characteristics in initiation of paroxysmal atrial fibrillation from a focal area. J Am Coll Cardiol 2000 37 : 1658 1664.
    • (2000) J Am Coll Cardiol , vol.37 , pp. 1658-1664
    • Lu, T.M.1    Tai, C.T.2    Hsieh, M.H.3
  • 4
    • 0034649299 scopus 로고    scopus 로고
    • Electrophysiological break-throughs from the left atrium to the pulmonary veins
    • Haissaguerre M, Shah DC, Jais P, et al : Electrophysiological break-throughs from the left atrium to the pulmonary veins. Circulation 2000 102 : 2463 2465.
    • (2000) Circulation , vol.102 , pp. 2463-2465
    • Haissaguerre, M.1    Shah, D.C.2    Jais, P.3
  • 5
    • 0141615779 scopus 로고    scopus 로고
    • Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation: An electroanatomic study
    • Ernst S, Ouyang F, Lober F, et al : Catheter-induced linear lesions in the left atrium in patients with atrial fibrillation: An electroanatomic study. J Am Coll Cardiol 2003 42 : 1271 1282.
    • (2003) J Am Coll Cardiol , vol.42 , pp. 1271-1282
    • Ernst, S.1    Ouyang, F.2    Lober, F.3
  • 6
    • 0037036848 scopus 로고    scopus 로고
    • Circular mapping and ablation of the pulmonary veins for treatment of atrial fibrillation: Impact of different catheter technologies
    • Marrouche NF, Dresing T, Cole C, et al : Circular mapping and ablation of the pulmonary veins for treatment of atrial fibrillation: Impact of different catheter technologies. J Am Coll Cardiol 2002 40 : 464 474.
    • (2002) J Am Coll Cardiol , vol.40 , pp. 464-474
    • Marrouche, N.F.1    Dresing, T.2    Cole, C.3
  • 7
    • 33644607129 scopus 로고    scopus 로고
    • Trans-septal cathetterization in the electrophysiology laboratory. Data from a multicenter survey spanning 12 years
    • De Ponti R, Cappato R, Curnis A, et al : Trans-septal cathetterization in the electrophysiology laboratory. Data from a multicenter survey spanning 12 years. J Am Coll Cardiol 2006 47 : 1037 1042.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1037-1042
    • De Ponti, R.1    Cappato, R.2    Curnis, A.3
  • 9
    • 0028146592 scopus 로고
    • The technique and safety of transseptal left heart catherization: The Massachusetts General Hospital experience with 1,279 procedures
    • Roelke M, Smith AJC, Palacios IF : The technique and safety of transseptal left heart catherization: The Massachusetts General Hospital experience with 1,279 procedures. Cathet Cardiovasc Diagn 1994 32 : 332 339.
    • (1994) Cathet Cardiovasc Diagn , vol.32 , pp. 332-339
    • Roelke, M.1    Smith, A.J.C.2    Palacios, I.F.3
  • 10
    • 0032102109 scopus 로고    scopus 로고
    • Trans-septal catheterization for radiofrequency catheter ablation of cardiac arrhythmias. Results and safety of a simplified method
    • De Ponti R, Zardini M, Storti C et al : Trans-septal catheterization for radiofrequency catheter ablation of cardiac arrhythmias. Results and safety of a simplified method. Eur Heart J 1998 19 : 943 950.
    • (1998) Eur Heart J , vol.19 , pp. 943-950
    • De Ponti, R.1    Zardini, M.2    Storti, C.3
  • 11
    • 0037711845 scopus 로고    scopus 로고
    • Bezold-Jarish-like reflex during Brockenbrough's procedure for radiofrequency catheter ablation of focal left atrial fibrillation: Report of two cases
    • Arita T, Kubota S, Ojkamoto K, et al : Bezold-Jarish-like reflex during Brockenbrough's procedure for radiofrequency catheter ablation of focal left atrial fibrillation: Report of two cases. J Int Card Electrophysiol 2003 8 : 195 202.
    • (2003) J Int Card Electrophysiol , vol.8 , pp. 195-202
    • Arita, T.1    Kubota, S.2    Ojkamoto, K.3
  • 12
    • 7744232153 scopus 로고    scopus 로고
    • Persistence of septal defect after transeptal puncture for pulmonary vein isolation procedures
    • 14.
    • Obel O, Mansour M, Picard M, Ruskin J, Keane D : Persistence of septal defect after transeptal puncture for pulmonary vein isolation procedures. PACE 2004 27 : 1411 : 14.
    • (2004) PACE , vol.27 , pp. 1411
    • Obel, O.1    Mansour, M.2    Picard, M.3    Ruskin, J.4    Keane, D.5
  • 13
    • 0024830736 scopus 로고
    • Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping
    • Yoshida K, Yoshikawa J, Akasaka T, et al : Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping. Circulation 1989 80 : 1521 1526.
    • (1989) Circulation , vol.80 , pp. 1521-1526
    • Yoshida, K.1    Yoshikawa, J.2    Akasaka, T.3
  • 14
    • 0023895824 scopus 로고
    • Prevalence of patent foramen ovale in patients with stroke
    • Lechat P, Mas JL, Lascault G, et al : Prevalence of patent foramen ovale in patients with stroke. N Engl J Med 1988 318 : 1148 1152.
    • (1988) N Engl J Med , vol.318 , pp. 1148-1152
    • Lechat, P.1    Mas, J.L.2    Lascault, G.3
  • 15
    • 0032990418 scopus 로고    scopus 로고
    • Intracardiac echocardiography to guide transseptal left heart catheterization for radiofrequency catheter ablation
    • Daoud EG, Kalbfleish SJ, Hummel JD : Intracardiac echocardiography to guide transseptal left heart catheterization for radiofrequency catheter ablation. J Cardiovasc Electrophysiol 1999 10 : 358 363.
    • (1999) J Cardiovasc Electrophysiol , vol.10 , pp. 358-363
    • Daoud, E.G.1    Kalbfleish, S.J.2    Hummel, J.D.3
  • 16
    • 12144288944 scopus 로고    scopus 로고
    • High-flow perfusion of sheaths for prevention of thromboembolic complications during complex catheter ablation in the left atrium
    • Cauchemez B, Extramania F, Cauchemez S, et al : High-flow perfusion of sheaths for prevention of thromboembolic complications during complex catheter ablation in the left atrium. J Cardiovasc Electrophysiol 2004 15 : 276 283.
    • (2004) J Cardiovasc Electrophysiol , vol.15 , pp. 276-283
    • Cauchemez, B.1    Extramania, F.2    Cauchemez, S.3
  • 17
    • 20444389767 scopus 로고    scopus 로고
    • Intracardiac ultrasound detection of thrombus on transseptal sheath: Incidence, treatment, and prevention
    • Maleki K, Mohammadi R, Hart D, et al : Intracardiac ultrasound detection of thrombus on transseptal sheath: Incidence, treatment, and prevention. J Cardiovasc Electrophysiol 2005 16 : 561 565.
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 561-565
    • Maleki, K.1    Mohammadi, R.2    Hart, D.3
  • 18
    • 2442625672 scopus 로고    scopus 로고
    • Left atrial thrombus associated with ablation for atrial fibrillation: Identification with intracardiac echocardiography
    • Ren JF, Marchlinski FE, Callans DJ : Left atrial thrombus associated with ablation for atrial fibrillation: Identification with intracardiac echocardiography. J Am Coll Cardiol 2004 43 : 1861 1867.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1861-1867
    • Ren, J.F.1    Marchlinski, F.E.2    Callans, D.J.3
  • 19
    • 0034828641 scopus 로고    scopus 로고
    • Plasma von Willebrand factor, fibrinogen and soluble P-selectin levels in paroxysmal, persistent, and permanent atrial fibrillation
    • Li-Saw-Hee FL, Blann AD, Gurney D, et al : Plasma von Willebrand factor, fibrinogen and soluble P-selectin levels in paroxysmal, persistent, and permanent atrial fibrillation. Eur Heart J 2001 22 : 1741 1747.
    • (2001) Eur Heart J , vol.22 , pp. 1741-1747
    • Li-Saw-Hee, F.L.1    Blann, A.D.2    Gurney, D.3
  • 20
    • 0036673899 scopus 로고    scopus 로고
    • Cerebrovascular complication associated with pulmonary vein ablation
    • Kok LC, Mangrum JM, Haines DE, et al : Cerebrovascular complication associated with pulmonary vein ablation. J Cardiovasc Electrophysiol 2002 13 : 764 767.
    • (2002) J Cardiovasc Electrophysiol , vol.13 , pp. 764-767
    • Kok, L.C.1    Mangrum, J.M.2    Haines, D.E.3
  • 21
    • 33845688401 scopus 로고    scopus 로고
    • Repeat transseptal catheterization after ablation for atrial fibrillation
    • Marcus GM, Xiushui R, Tseng ZH, et al : Repeat transseptal catheterization after ablation for atrial fibrillation. J Cardiovasc Electrophysiol 2007 18 : 55 59.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 55-59
    • Marcus, G.M.1    Xiushui, R.2    Tseng, Z.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.