메뉴 건너뛰기




Volumn 19, Issue 1, 2009, Pages 41-48

Accuracy of pedicle screw placement using intraoperative neurophysiological monitoring and computed tomography

Author keywords

Electromyography; Intraoperative neurophysiological monitoring; Pedicle screw fixation

Indexed keywords

ELECTROMYOGRAPHY; ELECTROPHYSIOLOGY; NEUROPHYSIOLOGY; SCREWS; SURGERY;

EID: 77951132664     PISSN: 10506934     EISSN: None     Source Type: Journal    
DOI: 10.1615/jlongtermeffmedimplants.v19.i1.50     Document Type: Article
Times cited : (7)

References (31)
  • 1
    • 0033493426 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion with cages: An independent review of 71 cases
    • Agazzi S, Reverdim A, May D. Posterior lumbar interbody fusion with cages: an independent review of 71 cases. J Neurosurg. 1999;91: 186-192
    • (1999) J Neurosurg , vol.91 , pp. 186-192
    • Agazzi, S.1    Reverdim, A.2    May, D.3
  • 2
    • 0034214346 scopus 로고    scopus 로고
    • Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system
    • Brantigan JW, Steff e AD, Lewis ML, Quinn LM, Persenaire JM. Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and the variable pedicle screw placement system. Spine. 2000;25: 1437-1446
    • (2000) Spine , vol.25 , pp. 1437-1446
    • Brantigan, J.W.1    Steff, E.A.D.2    Lewis, M.L.3    Quinn, L.M.4    Persenaire, J.M.5
  • 3
    • 0029870260 scopus 로고    scopus 로고
    • Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography
    • Darden BV 2nd, Wood KE, Hatley MK, Owen JH, Kostuik J. Evaluation of pedicle screw insertion monitored by intraoperative evoked electromyography. J Spinal Disord. 1996;9:8-16.
    • (1996) J Spinal Disord , vol.9 , pp. 8-16
    • Darden II, B.V.1    Wood, K.E.2    Hatley, M.K.3    Owen, J.H.4    Kostuik, J.5
  • 4
    • 0033921392 scopus 로고    scopus 로고
    • Complications of posterior lumbar interbody fusion when using a titanium threaded cage device
    • Elias WJ, Simmons NE, Kaptain GJ, Chadduck JB, Whitehill R. Complications of posterior lumbar interbody fusion when using a titanium threaded cage device. J Neurosurg. 2000;93(suppl 1):45-52.
    • (2000) J Neurosurg , vol.93 , Issue.SUPPL. 1 , pp. 45-52
    • Elias, W.J.1    Simmons, N.E.2    Kaptain, G.J.3    Chadduck, J.B.4    Whitehill, R.5
  • 5
    • 0032751425 scopus 로고    scopus 로고
    • Posterior lumbar interbody fusion: A retrospective study of complications after facet joint excision and pedicle screw fi xation in 148 cases
    • Okuyama K, Abe E, Suzuki T, Tamura Y, Chiba M, Sato K. Posterior lumbar interbody fusion: A retrospective study of complications after facet joint excision and pedicle screw fi xation in 148 cases. Acta Orthop Scand. 1999;70:329-334
    • (1999) Acta Orthop Scand , vol.70 , pp. 329-334
    • Okuyama, K.1    Abe, E.2    Suzuki, T.3    Tamura, Y.4    Chiba, M.5    Sato, K.6
  • 6
    • 0030936398 scopus 로고    scopus 로고
    • Complications of transpedicular lumbosacral fi xation for non-traumatic disorders
    • Pihlajamaki H, Myllynen, Bostman O. Complications of transpedicular lumbosacral fi xation for non-traumatic disorders. J Bone Joint Surg Am. 1997;79B:183-189
    • (1997) J Bone Joint Surg Am , vol.79 B , pp. 183-189
    • Pihlajamaki, H.1    Myllynen Bostman, O.2
  • 7
    • 0031573727 scopus 로고    scopus 로고
    • 1997 Volvo Award winner in clinical studies. Th e eff ect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: A prospective, randomized clinical study
    • Th omsen K, Christensen FB, Eiskjaer SP, Hansen ES, Fruensgaard S, Bunger CE. 1997 Volvo Award winner in clinical studies. Th e eff ect of pedicle screw instrumentation on functional outcome and fusion rates in posterolateral lumbar spinal fusion: a prospective, randomized clinical study. Spine. 1997;22:2813-2822
    • Spine , vol.1997 , Issue.22 , pp. 2813-2822
    • Thomsen, K.1    Christensen, F.B.2    Eiskjaer, S.P.3    Hansen, E.S.4    Fruensgaard, S.5    Bunger, C.E.6
  • 10
    • 0033834682 scopus 로고    scopus 로고
    • Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis
    • Halm HF, Niemeyer T, Link T, Liljenqvist U. Segmental pedicle screw instrumentation in idiopathic thoracolumbar and lumbar scoliosis. Eur Spine J. 2000;9:192-197
    • (2000) Eur Spine J , vol.9 , pp. 192-197
    • Halm, H.F.1    Niemeyer, T.2    Link, T.3    Liljenqvist, U.4
  • 11
    • 0031413907 scopus 로고    scopus 로고
    • Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis
    • Liljenqvist UR, Halm HF, Link TM. Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis. Spine. 1997;22: 2239-2245
    • (1997) Spine , vol.22 , pp. 2239-2245
    • Liljenqvist, U.R.1    Halm, H.F.2    Link, T.M.3
  • 13
    • 0025879589 scopus 로고
    • Complications of variable screw plate pedicle screw fi xation
    • West JL, Ogilvie JW, Bradford DS. Complications of variable screw plate pedicle screw fi xation. Spine 1991;16:577-579
    • (1991) Spine , vol.16 , pp. 577-579
    • West, J.L.1    Ogilvie, J.W.2    Bradford, D.S.3
  • 14
    • 0036644991 scopus 로고    scopus 로고
    • Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery
    • Bose B, Wierzbowski LR, Sestokas AK. Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery. Spine. 2002;27:1444-1450
    • (2002) Spine , vol.27 , pp. 1444-1450
    • Bose, B.1    Wierzbowski, L.R.2    Sestokas, A.K.3
  • 15
    • 0033568321 scopus 로고    scopus 로고
    • Evaluation of pedical screw position in thoracic and lumbar spine fi xation using plain radiographs and computed tomography. A prospective study of 35 patients
    • Sapkas GS, Papadakis SA, Stathakapoulas DP, Papagelopoulos PJ, Badekas AC, Kaiser JH. Evaluation of pedical screw position in thoracic and lumbar spine fi xation using plain radiographs and computed tomography. A prospective study of 35 patients. Spine. 1999;24: 1926-1929
    • (1999) Spine , vol.24 , pp. 1926-1929
    • Sapkas, G.S.1    Papadakis, S.A.2    Stathakapoulas, D.P.3    Papagelopoulos, P.J.4    Badekas, A.C.5    Kaiser, J.H.6
  • 16
    • 0028909540 scopus 로고
    • Continuous intraoperative electromyographic recording during spinal surgery
    • Beatty RM, McGuire P, Moroney JM, Holladay FP. Continuous intraoperative electromyographic recording during spinal surgery. J Neurosurg. 1995;82:401-405
    • (1995) J Neurosurg , vol.82 , pp. 401-405
    • Beatty, R.M.1    McGuire, P.2    Moroney, J.M.3    Holladay, F.P.4
  • 17
    • 0028586882 scopus 로고
    • Stimulusevoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results
    • Calancie B, Madsen P, Lebwohl N. Stimulusevoked EMG monitoring during transpedicular lumbosacral spine instrumentation. Initial clinical results. Spine. 1994;19:2780-2786
    • (1994) Spine , vol.19 , pp. 2780-2786
    • Calancie, B.1    Madsen, P.2    Lebwohl, N.3
  • 18
    • 0029018888 scopus 로고
    • A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomography scan confi rmation
    • Glassman SD, Dimar JR, Puno RM, Johnson JR, Shields CB, Linden RD. A prospective analysis of intraoperative electromyographic monitoring of pedicle screw placement with computed tomography scan confi rmation. Spine. 1995;20:1375-1379
    • (1995) Spine , vol.20 , pp. 1375-1379
    • Glassman, S.D.1    Dimar, J.R.2    Puno, R.M.3    Johnson, J.R.4    Shields, C.B.5    Linden, R.D.6
  • 19
    • 0028957058 scopus 로고
    • Evaluation of intrapedicular screw position using intraoperative evoked electromyography
    • Maguire J, Wallace S, Madiga R, Leppanen R, Draper V. Evaluation of intrapedicular screw position using intraoperative evoked electromyography. Spine. 1995;20:1068-1074
    • (1995) Spine , vol.20 , pp. 1068-1074
    • Maguire, J.1    Wallace, S.2    Madiga, R.3    Leppanen, R.4    Draper, V.5
  • 20
    • 0030741966 scopus 로고    scopus 로고
    • Evaluation with evoked and spontaneous elec- tromyography during lumbar instrumentation: A prospective study
    • Welch WC, Rose RD, Balzer JR, Jacobs GB. Evaluation with evoked and spontaneous elec- tromyography during lumbar instrumentation: A prospective study. J Neurosurg. 1997;87: 397-402.
    • (1997) J Neurosurg , vol.87 , pp. 397-402
    • Welch, W.C.1    Rose, R.D.2    Balzer, J.R.3    Jacobs, G.B.4
  • 21
    • 0027484342 scopus 로고
    • Complications associated with the technique of pedicle screw fi xation
    • Esses SI, Sachs BL, Dreyzin V. Complications associated with the technique of pedicle screw fi xation. Spine. 1993;18:2231-2239
    • (1993) Spine , vol.18 , pp. 2231-2239
    • Esses, S.I.1    Sachs, B.L.2    Dreyzin, V.3
  • 22
    • 0025267440 scopus 로고
    • Accuracy of pedicular screw placement in vivo
    • Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine. 1990;15: 11-14
    • (1990) Spine , vol.15 , pp. 11-14
    • Gertzbein, S.D.1    Robbins, S.E.2
  • 24
    • 0742269914 scopus 로고    scopus 로고
    • Free hand pedicle screw placement in thoracic spine: Is it safe?
    • Kim YJ, Lenke LG, Bridwell KH, Cho YS, Riew KD. Free hand pedicle screw placement in thoracic spine: Is it safe? Spine. 2004;29:333-342
    • (2004) Spine , vol.29 , pp. 333-342
    • Kim, Y.J.1    Lenke, L.G.2    Bridwell, K.H.3    Cho, Y.S.4    Riew, K.D.5
  • 25
    • 0031950288 scopus 로고
    • Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws
    • Moed RB, Ahmad BK, Craig JG, Jacobson GP, Anders MJ. Intraoperative monitoring with stimulus-evoked electromyography during placement of iliosacral screws. J Bone Joint Surg Am. 1988;80A:537-546
    • (1988) J Bone Joint Surg Am , vol.80 A , pp. 537-546
    • Moed, R.B.1    Ahmad, B.K.2    Craig, J.G.3    Jacobson, G.P.4    Anders, M.J.5
  • 26
    • 0026738114 scopus 로고
    • Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement
    • Calancie B, Lebwohl N, Madsen P, Klose KJ. Intraoperative evoked EMG monitoring in an animal model. A new technique for evaluating pedicle screw placement. Spine. 1992;17: 1229-1235
    • (1992) Spine , vol.17 , pp. 1229-1235
    • Calancie, B.1    Lebwohl, N.2    Madsen, P.3    Klose, K.J.4
  • 27
    • 0029093114 scopus 로고
    • Triggered electromyographic threshold for accuracy of thoracic pedicle screw placement. An animal model and clinical correlation
    • Lenke LG, Padberg AM, Russo MH, Bridwell KH, Gelb DE. Triggered electromyographic threshold for accuracy of thoracic pedicle screw placement. An animal model and clinical correlation. Spine. 1995;20:1585-1591
    • (1995) Spine , vol.20 , pp. 1585-1591
    • Lenke, L.G.1    Padberg, A.M.2    Russo, M.H.3    Bridwell, K.H.4    Gelb, D.E.5
  • 28
    • 0034803313 scopus 로고    scopus 로고
    • Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws
    • Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA. Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Joint Surg Br. 2001;83:1009-1014
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 1009-1014
    • Reidy, D.P.1    Houlden, D.2    Nolan, P.C.3    Kim, M.4    Finkelstein, J.A.5
  • 29
    • 34848911899 scopus 로고    scopus 로고
    • Intraoperative neurophysiologic monitoring during spinal surgery
    • Devlin VJ, Schwartz DM. Intraoperative neurophysiologic monitoring during spinal surgery. J Am Acad Orthop Surg. 2007;15:549-560
    • (2007) J Am Acad Orthop Surg , vol.15 , pp. 549-560
    • Devlin, V.J.1    Schwartz, D.M.2
  • 30
    • 36249019705 scopus 로고    scopus 로고
    • Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: Analysis of 4857 screws
    • Raynor BL, Lenke LG, Bridwell KH, Taylor BA, Padberg AM. Correlation between low triggered electromyographic thresholds and lumbar pedicle screw malposition: analysis of 4857 screws. Spine. 2007;32:2673-2678
    • (2007) Spine , vol.32 , pp. 2673-2678
    • Raynor, B.L.1    Lenke, L.G.2    Bridwell, K.H.3    Taylor, B.A.4    Padberg, A.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.