메뉴 건너뛰기




Volumn , Issue , 2009, Pages 6072-6075

MRI compatibility evaluation of a piezoelectric actuator system for a neural interventional robot

Author keywords

[No Author keywords available]

Indexed keywords

ACTUATORS; DIAGNOSIS; MAGNETIC RESONANCE IMAGING; NEUROSURGERY; ROBOTICS; SIGNAL INTERFERENCE; SURGERY;

EID: 77950998266     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5334206     Document Type: Conference Paper
Times cited : (35)

References (15)
  • 1
    • 33748139412 scopus 로고    scopus 로고
    • A randomized trial of deep-brain stimulation for parkinson's disease
    • Aug
    • G. Deuschl, et al., "A randomized trial of deep-brain stimulation for parkinson's disease.," N Engl J Med, vol.355, pp. 896-908, Aug 2006.
    • (2006) N Engl J Med , vol.355 , pp. 896-908
    • Deuschl, G.1
  • 2
    • 27744586945 scopus 로고    scopus 로고
    • Deep brain stimulation for ocd and major depression
    • Nov
    • B. Aouizerate, et al., "Deep brain stimulation for ocd and major depression.," Am J Psychiatry, vol.162, p. 2192, Nov 2005.
    • (2005) Am J Psychiatry , vol.162 , pp. 2192
    • Aouizerate, B.1
  • 3
    • 0036323903 scopus 로고    scopus 로고
    • Implantation of deep brain stimulators into the subthalamic nucleus: Technical approach and magnetic resonance imaging-verified lead locations
    • Aug
    • P. A. Starr, C. W. Christine, P. V. Theodosopoulos, N. Lindsey, D. Byrd, A. Mosley, and W. J. Marks, "Implantation of deep brain stimulators into the subthalamic nucleus: technical approach and magnetic resonance imaging-verified lead locations.," J Neurosurg, vol.97, pp. 370-387, Aug 2002.
    • (2002) J Neurosurg , vol.97 , pp. 370-387
    • Starr, P.A.1    Christine, C.W.2    Theodosopoulos, P.V.3    Lindsey, N.4    Byrd, D.5    Mosley, A.6    Marks, W.J.7
  • 4
  • 5
    • 35348853696 scopus 로고    scopus 로고
    • Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: A review study
    • N. V. Tsekos, A. Khanicheh, E. Christoforou, and C. Mavroidis, "Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study.," Annu Rev Biomed Eng, vol.9, pp. 351-387, 2007.
    • (2007) Annu Rev Biomed Eng , vol.9 , pp. 351-387
    • Tsekos, N.V.1    Khanicheh, A.2    Christoforou, E.3    Mavroidis, C.4
  • 6
    • 0029422530 scopus 로고
    • Development of an mri-compatible needle insertion manipulator for stereotactic neurosurgery
    • K. Masamune, E. Kobayashi, Y. Masutani, M.Suzuki, T. Dohi, H. Iseki, and K. Takakura, "Development of an mri-compatible needle insertion manipulator for stereotactic neurosurgery.," J Image Guid Surg, vol.1, no.4, pp. 242-248, 1995.
    • (1995) J Image Guid Surg , vol.1 , Issue.4 , pp. 242-248
    • Masamune, K.1    Kobayashi, E.2    Masutani, Y.3    Suzuki, M.4    Dohi, T.5    Iseki, H.6    Takakura, K.7
  • 7
    • 84945573291 scopus 로고    scopus 로고
    • Mri compatible surgical assist robot: System integration and preliminary feasibility study
    • October
    • K. Chinzei, N. Hata, F. A. Jolesz, and R. Kikinis, "Mri compatible surgical assist robot: System integration and preliminary feasibility study," in MICCAI, vol.1935, pp. 921-930, October 2000.
    • (2000) MICCAI , vol.1935 , pp. 921-930
    • Chinzei, K.1    Hata, N.2    Jolesz, F.A.3    Kikinis, R.4
  • 8
    • 33645814205 scopus 로고    scopus 로고
    • Mri/fmri-compatible robotic system with force feedback for interaction with human motion
    • April
    • R. Gassert, R. Moser, E. Burdet, and H. Bleuler, "Mri/fmri- compatible robotic system with force feedback for interaction with human motion," IEEE Trans Mech, vol.11, pp. 216-224, April 2006.
    • (2006) IEEE Trans Mech , vol.11 , pp. 216-224
    • Gassert, R.1    Moser, R.2    Burdet, E.3    Bleuler, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.