메뉴 건너뛰기




Volumn , Issue , 2009, Pages 1608-1611

In vivo testing of a low noise 32-channel wireless neural recording system

Author keywords

[No Author keywords available]

Indexed keywords

NEURAL NETWORKS; NEUROPHYSIOLOGY; PROGRAMMABLE LOGIC CONTROLLERS; RECORDING INSTRUMENTS; TIME DIVISION MULTIPLEXING;

EID: 77950967414     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2009.5333227     Document Type: Conference Paper
Times cited : (6)

References (8)
  • 1
    • 33749062944 scopus 로고    scopus 로고
    • Braincontrolled interfaces: Movement restoration with neural prosthetics
    • Oct.
    • A.B. Schwartz, X.T. Cui, D.J. Weber, and D.W. Moran, " Braincontrolled interfaces: movement restoration with neural prosthetics," Neuron, vol.52, pp. 205-220, Oct. 2006.
    • (2006) Neuron , vol.52 , pp. 205-220
    • Schwartz, A.B.1    Cui, X.T.2    Weber, D.J.3    Moran, D.W.4
  • 3
    • 85008063690 scopus 로고    scopus 로고
    • The design of integrated circuits to observe brain activity
    • July
    • R.R. Harrison, "The design of integrated circuits to observe brain activity," Proceedings of the IEEE, vol.96, pp. 1203-1216, July 2008.
    • (2008) Proceedings of the IEEE , vol.96 , pp. 1203-1216
    • Harrison, R.R.1
  • 4
    • 34548823775 scopus 로고    scopus 로고
    • A low-noise preamplifier with adjustable gain and bandwidth for biopotential recording applications
    • May
    • M. Yin and M. Ghovanloo, "A low-noise preamplifier with adjustable gain and bandwidth for biopotential recording applications," IEEE Intl. Symp. Circ. and Sys. (ISCAS) , pp.321-324, May 2007.
    • (2007) IEEE Intl. Symp. Circ. and Sys. (ISCAS) , pp. 321-324
    • Yin, M.1    Ghovanloo, M.2
  • 5
    • 51749109778 scopus 로고    scopus 로고
    • A clockless ultra low-noise low-power wireless implantable neural recording system
    • May
    • M. Yin and M. Ghovanloo, "A clockless ultra low-noise low-power wireless implantable neural recording system," in Proc. IEEE Intl. Symp. on Circuits and Systems, pp.1756-1759, May 2008.
    • (2008) Proc. IEEE Intl. Symp. on Circuits and Systems , pp. 1756-1759
    • Yin, M.1    Ghovanloo, M.2
  • 6
    • 11244299267 scopus 로고    scopus 로고
    • A compact large voltage compliance high output impedance programmable current source for biomedical implantable microstimulators
    • Jan.
    • M. Ghovanloo and K. Najafi, "A compact large voltage compliance high output impedance programmable current source for biomedical implantable microstimulators," IEEE Trans. on Biomed. Eng, vol.52, no.1, pp. 97-105, Jan. 2005.
    • (2005) IEEE Trans. on Biomed. Eng. , vol.52 , Issue.1 , pp. 97-105
    • Ghovanloo, M.1    Najafi, K.2
  • 7
    • 61849121987 scopus 로고    scopus 로고
    • A low-noise receiver for multichannel wireless neural recordingProc
    • Aug.
    • M. Yin and M. Ghovanloo, "A low-noise receiver for multichannel wireless neural recording," Proc. IEEE 30th Eng. in Med. and Biol. Conf., pp. 4222-4225, Aug. 2008.
    • (2008) IEEE 30th Eng. in Med. and Biol. Conf. , pp. 4222-4225
    • Yin, M.1    Ghovanloo, M.2
  • 8
    • 70349294317 scopus 로고    scopus 로고
    • A flexible 32-channel simultaneous wireless neural recording system with adjustable resolution
    • Digest of technical papers Feb.
    • M. Yin and M. Ghovanloo, "A flexible 32-channel simultaneous wireless neural recording system with adjustable resolution", Digest of technical papers IEEE Intl. Solid State Cir. Conf., pp. 432-433, Feb. 2009.
    • (2009) IEEE Intl. Solid State Cir. Conf. , pp. 432-433
    • Yin, M.1    Ghovanloo, M.2