Volumn 25, Issue 2, 2009, Pages 197-200

Dosimetric and image quality comparison of different 64-slice CT scanners

Author keywords

CT; Image quality; Radiation dose

Indexed keywords

BIOMEDICAL ENGINEERING; DIAGNOSIS; DOSIMETRY; IMAGE QUALITY; MEDICAL IMAGING; MEDICAL PHYSICS; PHANTOMS; SCANNING;

EID: 77950884011     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-642-03879-2_56     Document Type: Conference Paper
Times cited : (3)

References (10)
  • 3
    • 40949104442 scopus 로고    scopus 로고
    • The 2007 recommendations of the International Commission on Radiological Protection
    • ICRP Publication 103
    • ICRP Publication 103 (2007) The 2007 recommendations of the International Commission on Radiological Protection. Annals of the ICRP Volume37/2-4
    • (2007) Annals of the ICRP , vol.37 , pp. 2-4
  • 4
    • 77950887031 scopus 로고    scopus 로고
    • Basic anatomical and physiological data for use in radiological protection: The skeleton
    • ICRP Publication 70
    • ICRP Publication 70 (1996) Basic anatomical and physiological data for use in radiological protection: the skeleton. Pergamon Oxford.
    • (1996) Pergamon Oxford
  • 6
    • 4644367203 scopus 로고    scopus 로고
    • Variation in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: Implications for clinical dosimetry
    • Duggan L, Hood C, Warren-Forward H, Haque M, Kron T (2004) Variation in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry. Phys. Med. Biol. 49:3831-3845
    • (2004) Phys. Med. Biol. , vol.49 , pp. 3831-3845
    • Duggan, L.1    Hood, C.2    Warren-Forward, H.3    Haque, M.4    Kron, T.5
  • 8
    • 0003409650 scopus 로고
    • Normalised organ doses for X-ray computed tomography calculated using Monte Carlo techniques
    • Jones DG, Shrimpton PC (1993) Normalised organ doses for X-ray computed tomography calculated using Monte Carlo techniques. NRPB Report 250
    • (1993) NRPB Report 250
    • Jones, D.G.1    Shrimpton, P.C.2
  • 9
    • 77950898174 scopus 로고    scopus 로고
    • http://www.impactscan.org
  • 10
    • 33745430676 scopus 로고    scopus 로고
    • Dosimetric and image quality assessment of different acquisition protocols of a novel 64 slices CT scanner
    • SPIE PRESS
    • Vite C, Mangini M, Strocchi S (2006) Dosimetric and image quality assessment of different acquisition protocols of a novel 64 slices CT scanner. Proc. SPIE, Medical Imaging 2006: Physics of Medical Imaging, Vol 6142; 61423G, SPIE PRESS
    • (2006) Proc. SPIE, Medical Imaging 2006: Physics of Medical Imaging , vol.6142
    • Vite, C.1    Mangini, M.2    Strocchi, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.