Dosimetric and image quality assessment of different acquisition protocols of a novel 64 slices CT scanner

Author keywords

Dosimetry; Image quality; Multislice CT

Indexed keywords

BIOLOGICAL ORGANS; COMPUTERIZED TOMOGRAPHY; DOSIMETRY; IMAGE ANALYSIS; IMAGE QUALITY; OPTICAL RESOLVING POWER;

EID: 33745430676     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.650618     Document Type: Conference Paper
Times cited : (6)

References (12)
  • 1
    • 3242795133 scopus 로고    scopus 로고
    • Assessment of a theoretical formalism for dose estimation in CT: An anthropomorphic phantom study
    • Brix G, Lechel U, Veit R, et al "Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study", Eur. Radiol., 14(7), 1275-1284 (2004)
    • (2004) Eur. Radiol. , vol.14 , Issue.7 , pp. 1275-1284
    • Brix, G.1    Lechel, U.2    Veit, R.3
  • 2
    • 0042433484 scopus 로고    scopus 로고
    • A contribution to the establishment of diagnostic reference levels in CT
    • Hatziioannou K, Papanastassiou E, Delichas M, et al "A contribution to the establishment of diagnostic reference levels in CT", Br. J. Radio., 76(908), 541-545 (2003)
    • (2003) Br. J. Radio. , vol.76 , Issue.908 , pp. 541-545
    • Hatziioannou, K.1    Papanastassiou, E.2    Delichas, M.3
  • 3
    • 21244482569 scopus 로고    scopus 로고
    • Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models
    • Salvado M, Lopez M, Morant JJ, et al "Monte Carlo calculation of radiation dose in CT examinations using phantom and patient tomographic models", Radial. Prot. Dosimetry, 114(1-3), 364-368 (2005)
    • (2005) Radial. Prot. Dosimetry , vol.114 , Issue.1-3 , pp. 364-368
    • Salvado, M.1    Lopez, M.2    Morant, J.J.3
  • 5
    • 0344530444 scopus 로고    scopus 로고
    • Variations in radiation dose between the same model of multislice CT scanner at different hospitals
    • Koller CJ, Eatough JP, Bettrige A "Variations in radiation dose between the same model of multislice CT scanner at different hospitals", Br. J. Radiol., 76(911), 798-802 (2003)
    • (2003) Br. J. Radiol. , vol.76 , Issue.911 , pp. 798-802
    • Koller, C.J.1    Eatough, J.P.2    Bettrige, A.3
  • 6
    • 4644293782 scopus 로고    scopus 로고
    • 16-detector multislice CT: Dosimetry estimation by TLD measurement compared with Monte Carlo simulation
    • Groves AM, Owen KE, Courtney HM, et al "16-detector multislice CT: dosimetry estimation by TLD measurement compared with Monte Carlo simulation", Br. J. Radiol., 77(920), 662-665 (2004)
    • (2004) Br. J. Radiol. , vol.77 , Issue.920 , pp. 662-665
    • Groves, A.M.1    Owen, K.E.2    Courtney, H.M.3
  • 7
    • 25144433343 scopus 로고    scopus 로고
    • Use of an Automatic Exposure Control mechanism for dose optimization in multidetector row CT examinations, clinical evaluation
    • Mulkens TH, Bellinck P, Baeyaert M, et al "Use of an Automatic Exposure Control mechanism for dose optimization in multidetector row CT examinations, clinical evaluation", Radiology, 237(1), 213-223 (2005)
    • (2005) Radiology , vol.237 , Issue.1 , pp. 213-223
    • Mulkens, T.H.1    Bellinck, P.2    Baeyaert, M.3
  • 12
    • 43149106115 scopus 로고    scopus 로고
    • Medical imaging: The assessment of image quality
    • ICRU "Medical imaging: the assessment of image quality", ICRU Report 54 (1996)
    • (1996) ICRU Report , vol.54


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.